Page 46 of 332<br />

SUBSET-085, Issue 2.2.2<br />

November 9, 2007<br />

4.2.3.7 Balise Tele-powering Con<strong>for</strong>mity Measurements in the Side Lobe Zone<br />

Use the same test set-up as in sub-clause 4.2.3.3.1 on page 42. The test procedure is the same as in sub-clause<br />

4.2.3.3.3 on page 43, except <strong>for</strong> the geometrical test points, and that it is not needed to calculate the difference<br />

between P 27RL and P 27BA . Per<strong>for</strong>m the test procedure with the geometrical test points listed in clause C2 of<br />

Annex C on page 201. Exclude the geometrical points: [X = 200, Y = 0, Z = 220], [X = -200, Y = 0, Z = 220],<br />

[X = 0, Y = 150, Z = 220], and [X = 0, Y = -150, Z = 220].<br />

Plot the value P 27BA as a function of the position in four graphs, one <strong>for</strong> each quadrant.<br />

Please observe the limitations of the test tool expressed in sub-clause 4.2.3.6.<br />

4.2.3.8 Evaluation of Tele-powering Con<strong>for</strong>mity in the Side Lobe Zone<br />

Part 1 of this Norm specifies that the Balise shall be con<strong>for</strong>m with the “Reference Field” in the Side Lobe Zone.<br />

The Reference Field <strong>for</strong> the Tele-powering is defined in Part 1 of this Norm and recalled in sub-clause 4.2.3.6<br />

on page 45. The result of the Balise measurements <strong>for</strong> the Tele-powering in sub-clause 4.2.3.7 on page 46 shall<br />

be compared with the Reference Field. The tolerances <strong>for</strong> con<strong>for</strong>mity are stated in Part 1 of this Norm to be the<br />

same as <strong>for</strong> the Up-link, which means that the 27 MHz field needed to power the Balise may be from 5 dB below<br />

the Reference Field up to ∞. See Figure 13<br />

Contact zone<br />

Side lobe<br />

zone<br />

Cross-talk<br />

protected zone<br />

Reference field<br />

Reference Loop<br />

response<br />

5 dB<br />

Minimum current needed<br />

to activate Balise<br />

35 dB<br />

R0<br />

Figure 13: Minimum current (27 MHz) needed to activate the Balise in the Side Lobe Zone