Overload Relays – Panel Mount:<br />
Mitsubishi, S+S<br />
Overload Relays – Panel Mount Mitsubishi, Sprecher+Schuh<br />
TH-N60KP42A<br />
TH-N120TAKPUL105A<br />
CEP7-EEFD<br />
CEP7-EEEB<br />
CEP7-EEGE<br />
MiTSubiShi Th-N 3 PhASe<br />
• Simple installation. Two-hole mounting molded into base<br />
• No heaters required. Simple adjustment via front mounted dial<br />
• Selectable reset mode. Manual or automatic<br />
• Includes test button <strong>and</strong> trip indicator. Easy to troubleshoot<br />
• Easy to connect. Lugs or saddle clamp terminals included on line<br />
<strong>and</strong> load side<br />
• Not suitable for use with DC circuits<br />
Mitsubishi Part # Adjustment Range<br />
TH-N60KP22A 18 – 26 amps<br />
TH-N60KP29A 24 – 34 amps<br />
TH-N60KP35A 30 – 40 amps<br />
TH-N60KP42A 34 – 50 amps<br />
TH-N60KP54A 43 – 65 amps<br />
TH-N60TAKP67A 54 – 80 amps<br />
TH-N120TAKPUL105A 85 – 125 amps<br />
SPRecheR+Schuh ceP7 elecTRONic 3 PhASe<br />
• No heaters required. Simple adjustment via front mounted dial<br />
• Wide adjustment range. Four overload relay part numbers cover<br />
most applications<br />
• Selectable reset mode. Manual or automatic<br />
• Selectable trip classes. Class 10, 15, 20 or 30<br />
• Includes test button <strong>and</strong> trip indicator. Easy to troubleshoot<br />
• Easy to connect. Lugs or saddle clamp terminals included on line<br />
<strong>and</strong> load side<br />
• DIN rail mountable<br />
• Not suitable for use with DC circuits<br />
S+S Part # Adjustment Range Panel Mount Adapter<br />
CEP7-ED1CB* 1 – 5 amps CEP7-EPB<br />
CEP7-EEEB 5.4 – 27 amps CEP7-EPB<br />
CEP7-EEFD 9 – 45 amps CEP7-EPD<br />
CEP7-EEGE 18 – 90 amps CEP7-EPE<br />
* Class 10 manual reset only<br />
AROMAT 3 PhASe<br />
• No heaters required. Simple adjustment via front mounted dial<br />
• Selectable reset mode. Manual or automatic<br />
• Includes test button <strong>and</strong> trip indicator. Easy to troubleshoot<br />
• Easy to connect. Lugs or saddle clamp terminals included on line<br />
<strong>and</strong> load side<br />
• Comparatively inexpensive. Lowest cost dial-type overload relays<br />
• Not suitable for use with DC circuits<br />
Aromat Part # Adjustment Range<br />
FT65-16 12 – 18 amps<br />
FT50A-42 38 – 56 amps<br />
FT65-42 38 – 56 amps<br />
FT80A-42 38 – 56 amps<br />
FT50A-54 48 – 68 amps<br />
FT80A-54 48 – 68 amps<br />
FT125A-80 60 – 90 amps<br />
FT65-95 60 – 95 amps<br />
FT65L-95 80 – 110 amps<br />
FT125A-100 80 – 120 amps<br />
FT125A-105 85 – 125x amps<br />
Ge 3 PhASe TheRMAl<br />
• Uses type CR123C bimetallic heaters<br />
• Manual reset is st<strong>and</strong>ard<br />
• Includes test button <strong>and</strong> trip indicator. Easy to troubleshoot<br />
• Dial allows ± 10% adjustment of heater nominal rating<br />
• Easy to connect. Clamp-style terminals included on line <strong>and</strong> load side<br />
• Include 1NC contact<br />
• Comparatively inexpensive<br />
• Remember to purchase heaters!<br />
Ge Part # heater Range Note<br />
CR324C310A .35 27 amps<br />
CR324C360A .35 27 amps Comes with 1NO/1NC contacts<br />
CR324C610A1 .35 27 amps Auto reset<br />
CR324D310A 4.78 45 amps<br />
Overload Relays – Panel Mount Aromat, GE<br />
100 <strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />
<strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />
101<br />
FT50A-42<br />
FT80A-54<br />
FT65L-95<br />
FT125A-100<br />
Overload Relays – Panel Mount: Aromat, Ge