timers: iDec<br />
timers IDEC<br />
iDec Rte seRies continued<br />
Rte timing: P1+2 – B1+2 continued<br />
E: Signal OFF-Delay<br />
When power is turned on while the start input is on, the NO output contact goes on. When<br />
a preset time has elapsed after the start input turned off, the NO output contact goes off.<br />
Item<br />
Terminal<br />
Number<br />
Operation<br />
Power<br />
(A) 2 - 10<br />
(B) A - B<br />
Start<br />
(A) 5 - 6<br />
(B) 2 - 5<br />
Delayed<br />
Contact<br />
Indicator<br />
Set Time<br />
gt3a-3 timing:<br />
Delayed DPDt<br />
ON-Delay 1<br />
MODE<br />
A<br />
Interval 1<br />
MODE<br />
B<br />
(A) 1 - 4, 8 - 11<br />
(B) 1 - 7, 3 - 9<br />
(A) 1 - 3, 9 - 11<br />
(B) 4 - 7, 6 - 9<br />
PWR<br />
OUT<br />
Item<br />
Power 2 - 7<br />
Delayed<br />
Contact<br />
Terminal<br />
Number<br />
1 - 4, 5 - 8 (NC)<br />
1 - 3, 6 - 8 (NO)<br />
Indicator POWER<br />
OUT<br />
Item<br />
Power 2 - 7<br />
Delayed<br />
Contact<br />
(NC)<br />
(NO)<br />
iDec gt3a seRies – anaLog<br />
• 4 selectable operation modes on each model<br />
• External start, reset <strong>and</strong> pause inputs<br />
• Large variety of timing functions<br />
• Power <strong>and</strong> output status indicating LEDs<br />
Terminal<br />
Number<br />
1 - 4, 5 - 8 (NC)<br />
1 - 3, 6 - 8 (NO)<br />
Indicator POWER<br />
OUT<br />
T<br />
Ta<br />
T<br />
Operation<br />
Set Time<br />
Operation<br />
Set Time<br />
Ta<br />
8-Pin<br />
Operation<br />
3<br />
6<br />
Mode<br />
Selection (-)<br />
2<br />
7<br />
(+)<br />
1 8<br />
POWER<br />
F: One-Shot (signal start)<br />
When the start input turns on while power is on, the NO output contact goes on. When<br />
a preset time has elapsed, the NO output contact goes off.<br />
Item<br />
Terminal<br />
Number<br />
Operation<br />
Power<br />
(A) 2 - 10<br />
(B) A - B<br />
Start<br />
(A) 5 - 6<br />
(B) 2 - 5<br />
Delayed<br />
(A) 1 - 4, 8 - 11<br />
(B) 1 - 7, 3 - 9<br />
(NC)<br />
Contact (A) 1 - 3, 9 - 11<br />
(NO)<br />
(B) 4 - 7, 6 - 9<br />
4<br />
Indicator<br />
Set Time<br />
5<br />
Cycle 1<br />
(OFF fi rst)<br />
MODE<br />
C<br />
Cycle 3<br />
(ON fi rst)<br />
MODE<br />
D<br />
PWR<br />
OUT<br />
specifications: gt3af20<br />
Time Range 0.05 sec – 180 hours<br />
Rated Voltage 100 – 240VAC,<br />
12VDC,<br />
24VAC,<br />
24VDC<br />
Reset Time 60 msec maximum<br />
Contact Ratings 125VAC/250VAC, 5A;<br />
30VDC, 5A (resistive load)<br />
Mode of operation Rated Voltage code time Range output contact complete Part #<br />
A: ON-delay 1 AF20: 100 – 240VAC (50/60Hz) 0.05s – 180 hours 240VAC, 5A, Delayed DPDT GT3A-3AF20<br />
B: Interval 1 D12: 12V DC<br />
24VDC, 5A<br />
C: Cycle 1<br />
D: Cycle 3<br />
AD24: 24VAC (50/60Hz) 24VDC<br />
(resistive load)<br />
Item<br />
Power 2 - 7<br />
Delayed<br />
Contact<br />
Terminal<br />
Number<br />
1 - 4, 5 - 8 (NC)<br />
POWER<br />
Indicator<br />
OUT<br />
Item<br />
Power 2 - 7<br />
1 - 3, 6 - 8 (NO)<br />
Terminal<br />
Number<br />
Delayed<br />
1 - 4, 5 - 8 (NC)<br />
Contact<br />
Indicator<br />
POWER<br />
OUT<br />
(NO)<br />
Set Time<br />
Set Time<br />
GT3A-3AF20<br />
Operation<br />
Operation<br />
iDec gt3f seRies – tRue off DeLay<br />
• “True” power OFF-delay up to 10 minutes<br />
• No external control switch necessary<br />
specifications: gt3f-2af20<br />
Operation True power OFF-delay<br />
Time Range 0.05 sec – 600 secs<br />
Rated Voltage 100 – 240VAC,<br />
24VAC, VDC<br />
Contact Rating 250VAC/30VDC, 3A<br />
(resistive load)<br />
Contact Form DPDT<br />
Minimum Power<br />
1 sec<br />
Application Time<br />
iDec gt5y seRies – on DeLay<br />
gt3f-2 (8-pin) timing: Delayed DPDt<br />
• 4PDT, 3A or DPDT, 5A contacts<br />
• 4 time ranges<br />
• Control settings by h<strong>and</strong> or screwdriver<br />
• Power ON <strong>and</strong> timing out LED indicators<br />
• Uses the same sockets <strong>and</strong> hold-down clips as IDEC’s RY4S <strong>and</strong> RU series relays<br />
specifications gt5y-2 gt5y-4<br />
Rated Operating Voltage 100 – 120VAC<br />
200 – 240VAC<br />
24VDC<br />
24VAC<br />
Contact Form DPDT 4PDT<br />
Rated Load Resistive Load 220VAC, 5A 220VAC, 3A<br />
30VDC, 5A 30VDC, 3A<br />
Inductive Load 220VAC, 2A 220VAC, 0.8A<br />
30VDC, 2.5A 30VDC, 1.5A<br />
Allowable Contact Power Resistive Load 1100VA AC 660VA AC<br />
150W DC 90W DC<br />
Inductive Load 440VA AC 176VA AC<br />
Cos 0 = 0.3<br />
L/r = 7 msec<br />
75W DC 45W DC<br />
Allowable Voltage 250VAC, 125VDC<br />
Allowable Current 5A 3A<br />
Reset Time When turning power off after time up: 0.1 sec maximum<br />
When turning power off before time up: 1 sec maximum<br />
timers IDEC<br />
40 <strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />
<strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />
41<br />
Item<br />
Power<br />
Delayed<br />
Contact<br />
Indicator<br />
Set Time<br />
(-)<br />
Terminal<br />
Number<br />
2 - 7<br />
1 - 4<br />
5 - 8<br />
1 - 3<br />
6 - 8<br />
POWER<br />
(NC)<br />
(NO)<br />
4 5<br />
1 8<br />
POWER<br />
T = Set time<br />
Tr = Minimum Power Application Time<br />
3<br />
2<br />
7<br />
(+)<br />
When power is applied, the NO contact closes. When power is removed,<br />
the timing period begins. When time has elapsed, the NO contact opens.<br />
Optional reset input will return contacts to original state before time elapses.<br />
6<br />
Operation<br />
T Tr T<br />
GT3F-2AF20<br />
GT5Y-2SN3A100<br />
GT5Y-4SN6A100<br />
timers: iDec