<strong>Starters</strong> <strong>and</strong> <strong>Contactors</strong>: GE<br />

<strong>Starters</strong> <strong>and</strong> <strong>Contactors</strong> GE <strong>Starters</strong> <strong>and</strong> <strong>Contactors</strong> GE<br />

CR306A/B/C (CR306C shown)<br />

CR306D<br />

CR306E/F (CR306E shown)<br />

GE<br />

300 Line NEMA <strong>Starters</strong><br />

• Heavy-duty NEMA industrial design<br />

• Easy to replace coils <strong>and</strong> contacts<br />

• NEMA Type 1, 3R, <strong>and</strong> 12 enclosures readily available<br />

CR309C002BAA CR309C002<br />

200V 230V 460V Max Motor NEMA St<strong>and</strong>ard Aux Contacts<br />

HP HP HP Amps Size Catalog # NO NC Height Width Depth<br />

1-1/2 1-1/2 2 9 00 CR306A00 1 — 7” 3.7” 5.5”<br />

3 3 5 18 0 CR306B00 1 — 7” 3.7” 5.5”<br />

7-1/2 7-1/2 10 27 1 CR306C00 1 — 7” 3.7” 5.5”<br />

10 15 25 45 2 CR306D00 1 — 9” 4.6” 5.5”<br />

25 30 50 90 3 CR306E00 1 — 11.6” 6.6” 6.5”<br />

40 50 100 135 4 CR306F00 1 — 11.6” 6.6” 6.5”<br />

75 100 200 270 5 CR306G00 1 — 14” 11.5” 9”<br />

To complete catalog number, please specify AC coil voltage <strong>and</strong> overload relay amps.<br />

NEMA Reversing/Wye-Delta <strong>Contactors</strong><br />

NEMA Max<br />

Catalog # Size Amps Height Width Depth<br />

CR309A0 - -BAA 00 9 4.5” 8.9” 5”<br />

CR309B0 - -BAA 0 18 4.5” 8.9” 5”<br />

CR309C0 - -BAA 1 27 4.5” 8.9” 5”<br />

CR309D0 - -BAA 2 45 7” 10.4” 6.2”<br />

CR309E0 - -BAA 3 90 9” 15” 7.2”<br />

CR309F0 - -BAA 4 135 9” 15” 7.2”<br />

NEMA Reversing/Wye-Delta <strong>Starters</strong><br />

NEMA Max<br />

Catalog # Size Amps Height Width Depth<br />

CR309A0 - - 00 9 7” 8.9” 5”<br />

CR309B0 - - 0 18 7” 8.9” 5”<br />

CR309C0 - - 1 27 7” 8.9” 5”<br />

CR309D0 - - 2 45 9” 10.4” 6.2”<br />

CR309E0 - - 3 90 15” 15” 7.2”<br />

CR309F0 - - 4 135 15” 15” 7.2”<br />

NEMA <strong>Starters</strong>, Aux Contacts, Overload Relays, Coils,<br />

Contact Kits <strong>and</strong> <strong>Access</strong>ories<br />

66 <strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />

<strong>Access</strong> ElEvator supply • 800-266-8654 • Fax 510-652-5043 • www.aesupply.com<br />

67<br />

Mechanical<br />

Interlock #<br />

Contactor/<br />

Starter Size<br />

CR309X100B 0 – 1<br />

Notes<br />

For use with CR200 <strong>and</strong> CR300 line<br />

CR309X200D 2 For use with CR200 <strong>and</strong> CR300 line<br />

CR309X300B 3 – 4 For use with CR200 <strong>and</strong> CR300 line<br />

CR305X146C 0 – 6 Surge suppressor; connected in parallel with 120V coil<br />

Replacement T-bar<br />

Contact Carrier<br />

Contactor/<br />

Starter Size<br />

CR309X200D<br />

187D350P001 00 – 1<br />

Notes<br />

2, 3 <strong>and</strong> 4 pole/CR200 <strong>and</strong> CR300 line<br />

188D700P003 2 2 <strong>and</strong> 3 pole/CR200 <strong>and</strong> CR300 line<br />

55-152821G001 3 – 4 2 <strong>and</strong> 3 pole/CR200 line only<br />

55-750320P007 3 – 4 2 <strong>and</strong> 3 pole/CR300 line only<br />

55-154607G010 5 2 <strong>and</strong> 3 pole/CR200 line only<br />

55-154607G042 5 2 <strong>and</strong> 3 pole/CR300 line only<br />

CR309X100B<br />

CR309X300B<br />

CR305X146C<br />

187D350P001<br />

188D700P003 55-750320P007 55-154607G010<br />

<strong>Starters</strong> <strong>and</strong> <strong>Contactors</strong>: GE