Technical Particulars For Electric Ceiling Fans - csidc.cgeprocurem...
Technical Particulars For Electric Ceiling Fans - csidc.cgeprocurem...
Technical Particulars For Electric Ceiling Fans - csidc.cgeprocurem...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>Technical</strong> <strong>Particulars</strong> <strong>For</strong> <strong>Electric</strong> <strong>Ceiling</strong> <strong>Fans</strong><br />
Schedule 1 <strong>Electric</strong> <strong>Ceiling</strong> Fan Capacitor Type<br />
Unit : NOS.<br />
Sweep Size (mm) Type of Regulator fitte ISI Marking BEE star Rating<br />
d in ceiling fan<br />
1.1200 Without regulator Yes 5Star<br />
2.1200 Without regulator -------- 5Star<br />
3.1200 Resistance Yes ---<br />
4.1200 Resistance -------- 5Star<br />
5.1200 Without regulqator Yes --------<br />
6.1200 Electronic Yes 5Star<br />
7.1200 Electronic Yes ---------<br />
8.1200 Electronic -------- 5Star<br />
9.1400 Without Regulator Yes -------<br />
10.1400 Resistance Yes ------<br />
11.1400 electronic Yes -------<br />
NOTE TO TENDERERS:<br />
1. Type test reports shall be complete and satisfactory as per this T/E<br />
specification for each size of the fan and regulator with performance<br />
requirements at the rated voltage and shall be from any Govt. laboratory.<br />
2. Tenderers shall furnish copy of valid BIS Licence and/or BEE 5 star<br />
certificate, as applicable, along with their offer for the items covered<br />
under Schedule-1.<br />
3. Tenderer shall furnish Guaranteed <strong>Technical</strong> <strong>Particulars</strong> as per the<br />
Questionaire for each item quoted.<br />
4. IMPORTANT:<br />
With effect from next Rate Contract (2012-13), ceiling fans with 1200 mm and<br />
1400 mm sweep having ISI mark AND BEE 5 star rating shall ONLY be accepted.<br />
Further, only electronic regulators (step-type) shall be accepted. As such,<br />
item numbers 2,3,4,5, 7, 8,9,10& 11 of Schedule-1 shall stand DELETED in rate<br />
contract for year 2012-13. Hence,it is in the interest of the firms to get<br />
their products type tested as per relevant specifications of BIS and BEE 5<br />
star rating and get them registered with DGS&D, well in advance.<br />
5. Firms must submit their application to concerned QA Office for fresh or<br />
renewal of registration/capacity assessment/special capacity assessment PRIOR<br />
to 21 days before the scheduled date of tender opening,failing which their<br />
application shall NOT be entertained.
Detailed Specification<br />
Schedule 1 <strong>Electric</strong> <strong>Ceiling</strong> Fan Capacitor Type<br />
1. <strong>Electric</strong> ceiling fans shall be capacitor type, with double ball bearing<br />
complete with capacitor, 300 mm down rod, canopies, three number blades made<br />
of aluminum alloy, with suitable speed regulator, suitable for operation on<br />
single phase,AC 230 Volt, 50Hz supply and shall conform to class 1 of IS:<br />
374/1979 (Reaffirmed 2005).<br />
2. Wherever applicable, the ceiling fans shall be ISI marked and/or have BEE<br />
5 star marking.<br />
3. The electronic regulators (step type) shall conform to IS: 11037/1984<br />
(Reaffirmed 2005).<br />
4. The resistance type regulator shall confirm to IS:374/1979 (Reaffirmed<br />
2005).<br />
IMPORTANT NOTE:<br />
With effect from next Rate Contract (2012-13), ceiling fans with 1200 mm and<br />
1400 mm sweep having ISI mark AND BEE 5 star rating shall ONLY be accepted.<br />
Further, only electronic regulators (step-type) shall be accepted. As such,<br />
item numbers 2,3,4,5,7,8,9,10&11 of Schedule-1 shall stand DELETED in rate<br />
contract for year 2012- 13. Hence, it is in the interest of the firms to get<br />
their products type tested as per relevant specifications of BIS and BEE 5<br />
star rating and get them registered with DGS&D, well in advance.
Questionnaire<br />
Schedule <strong>Electric</strong> <strong>Ceiling</strong> Fan Capacitor Type<br />
1. Tenderers shall furnish following particulars for each<br />
item quoted separately. These particulars shall be same<br />
as that of type tested fan and shall match with the<br />
particulars specified in the TTC.<br />
Manufacturer's name trade name and model<br />
2 Sweep.<br />
3. Rated voltage<br />
4. Maximum input in watts at maximum speed and at rated<br />
voltage,<br />
5. Air delivery in cub.m/min at rated voltage,<br />
6. Maximum current at maximum speed at rated voltage.<br />
7. Power factor at rated voltage and maximum speed.<br />
8. Rated speed in RPM (without regulator) at rated voltage.<br />
9. Rated speed in RPM with speed regulator at maximum<br />
position and at<br />
rated voltage (as % of the rated speed).<br />
10. Type of motor, number of poles and degree of protection.<br />
11 Class of insulation.<br />
12 Material and size of winding wire used in the winding of<br />
the fan<br />
13 Material and diameter of shaft.<br />
14a) Type and material of the top bearing.<br />
14b) Type and material of the bottom bearing.<br />
15 Material and thickness of blades Range of blade angle and<br />
distance of the point from the centre at which it is to<br />
be measured.<br />
16 Size thickness and material of the down rod offered as<br />
standard.<br />
17 Material of the fan casing.<br />
18 Deviation if any from tender specification..<br />
19 Additional information if any.<br />
20 Weight of fan motor without blades and down rods.<br />
21 design/grade/type of magnetic material<br />
22 watt loss per kg<br />
23 weight of magnetic material<br />
24 weight of coil
General <strong>Technical</strong> requirement <strong>For</strong> TE :<br />
1. Type test reports shall be complete and satisfactory as per T/E<br />
specification for each size of the fan and regulator with performance<br />
requirements at the rated voltage and shall be from any Govt. laboratory.<br />
Type Test reports shall be required at the time of registration and<br />
inspection.<br />
Type test report shall indicate clearly & categorically the following<br />
parameters:-<br />
a) Blade angle at root, elevation and at tip<br />
b) Width, thickness and material of the blade.<br />
c) Capacitance value.<br />
d) Material of the body of the fan motor<br />
e) Total weight of the fan motor.<br />
2. Blade thickness without paint shall be as follows:-<br />
Sweep Size Minimum Blade thickness<br />
1200 mm 1.0 mm<br />
1400 mm 1.1 mm<br />
3. The material of the fan blade shall be of designation 31500B with<br />
condition Hx6 Aluminium Alloy Sheet conforming to IS:737/2008.<br />
4. The load bearing bolt shall be of min. 6 mm dia with Aluminium Clamp,<br />
Spring Washer, Nut and Checknut and Split Pin.<br />
5. Down rod shall be of 1.6 mm nominal thick ERW pipe.<br />
6. Shackle made from 2 mm nominal thick CRC sheet and<br />
7. Bolts (2 Nos) shall be 6mm with Spring Washer Nut and Checknut and Split<br />
Pin.<br />
8. Shank shall be made of CRC sheet of thickness 1.6 mm minimum without paint<br />
for all sizes.<br />
NOTE TO TENDERERS:<br />
1. Type test reports shall be complete and satisfactory as per this T/E<br />
specification for each size of the fan and regulator with performance<br />
requirements at the rated voltage and shall be from any Govt. laboratory.<br />
2. Tenderers shall furnish copy of valid BIS Licence and/or BEE 5 star<br />
certificate, as applicable, along with their offer for the items covered<br />
under Schedule-1.<br />
3. Tenderer shall furnish Guaranteed <strong>Technical</strong> <strong>Particulars</strong> as per the<br />
Questionaire for each item quoted.<br />
4. IMPORTANT:<br />
With effect from next Rate Contract (2012-13), ceiling fans with 1200 mm and<br />
1400 mm sweep having ISI mark AND BEE 5 star rating shall ONLY be accepted.<br />
Further, only electronic regulators (step-type) shall be accepted. As such,<br />
item numbers 2,3,4,5, 7, 8,9,10& 11 of Schedule-1 shall stand DELETED in rate<br />
contract for year 2012-13. Hence, it is in the interest of the firms to get<br />
their products type tested as per relevant specifications of BIS and BEE 5<br />
star rating and get them registered with DGS&D, well in advance.<br />
5. Firms must submit their application to concerned QA Office for fresh or<br />
renewal of registration/capacity assessment/special capacity assessment PRIOR<br />
to 21 days before the scheduled date of tender opening,failing which their<br />
application shall NOT be entertained.
NOTE TO QA OFFICERS:<br />
Over and above normal process, following points shall also be kept in view<br />
during inspection:<br />
1. <strong>For</strong> longevity of funtioning with declared power consumption, it is<br />
essential that appropriate category of stampings (magnetic material) are<br />
utilised by manufacturers, as per governing specification of the product.<br />
2. The blade angle should be exactly in consonance with the blade angle of<br />
fan type tested by independent Govt lab.<br />
3. DQA concerned may decide suitably with regard to verification of air<br />
delivery of different sizes of fans on rate contract, once during the<br />
currency of RC, for comparing of data obtained with production lot and type<br />
tested fan, as a validation process.<br />
4. Periodically, chemistry and mechnical property of blades should be<br />
verified by QA officer and DQA may decide the periodicity of same and<br />
assessment methodology.<br />
5. QA officers should stamp each Fan blade of samples drawn for testing.<br />
Remaining blades of the lot will be stamped on cartons of blade packing, at<br />
the time of inspection.<br />
6. Connecting documents pertaining to raw materials shall be furnished by the<br />
firm.<br />
7. QA officer shall record weight of fan motor in the inspection report.