Metasys Network Sales Resource Manual 635<br />

Application Specific Controllers Section<br />

Product Bulletin<br />

Issue Date 1000<br />

<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>,<br />

<strong>XPx</strong> Expansion <strong>Modules</strong><br />

The <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> extension modules<br />

used with <strong>XPx</strong> expansion modules combine<br />

intelligent processing power with exp<strong>and</strong>ed<br />

Input/Output (I/O). The <strong>XTM</strong>-<strong>105</strong> is intended for<br />

the N2 Bus, <strong>and</strong> the <strong>XTM</strong>-<strong>905</strong> works on the XT<br />

Bus of the DX controller series. Both support the<br />

<strong>XPx</strong> expansion modules to provide flexible,<br />

cost-effective point multiplexing <strong>and</strong> easy<br />

expansion for future retrofits. Light-Emitting Diode<br />

(LED) displays for diagnostics <strong>and</strong> manual<br />

override switches facilitate equipment startup <strong>and</strong><br />

testing, while magnetic or electric latching relays<br />

enable proper restart actions after a power outage.<br />

These modules offer an alternative to hardwiring<br />

many points from a remote location back to the<br />

controller, with the proven control <strong>and</strong> reliability<br />

typical of the Metasys® family of modular<br />

components.<br />

Note:<br />

The <strong>XTM</strong>-<strong>905</strong> supports a maximum of<br />

four <strong>XPx</strong> expansion modules.<br />

Figure 1: <strong>XTM</strong>-<strong>105</strong> <strong>Extension</strong> Module <strong>and</strong><br />

<strong>XPx</strong>-xxx Expansion <strong>Modules</strong><br />

❑ Modular Design<br />

❑ Status LEDs<br />

❑ H<strong>and</strong>/Off/Auto Switch<br />

❑ Built-in Line Voltage Relays<br />

❑ <strong>XTM</strong> Configurator<br />

(<strong>XTM</strong>-<strong>105</strong>)<br />

GX Tool (<strong>XTM</strong>-<strong>905</strong>)<br />

Features <strong>and</strong> Benefits<br />

Allows connection with expansion modules to<br />

provide I/O combinations for distributed or<br />

high-density monitoring <strong>and</strong> control.<br />

(The <strong>XTM</strong>-<strong>905</strong> has 16 I/O combinations, while<br />

the <strong>XTM</strong>-<strong>105</strong> has 40.)<br />

Provide an easy-to-read display for viewing<br />

I/O point status.<br />

Allows for direct manual override control of<br />

outputs for temporary on-site adjustments.<br />

Informs supervisory system of override<br />

conditions.<br />

Result in more economical installation <strong>and</strong><br />

maintenance; eliminates the installation costs<br />

of separately mounted relays. (Relay contacts<br />

rated 250 VAC at 3 Amperes maximum.)<br />

Provide user-friendly options for configuration<br />

to meet your system requirements. (Both are<br />

Windows®-based programs.)<br />

© 2000 Johnson Controls, Inc. 1<br />

Code No. LIT-635192<br />

www.johnsoncontrols.com


E R<br />

-<br />

F<br />

2 N<br />

+<br />

2 N<br />

N2 Bus<br />

<strong>XTM</strong>-<strong>105</strong>/<strong>XPx</strong> DX-9100 <strong>XTM</strong>-<strong>105</strong>/<strong>XPx</strong> DX-9100<br />

XT Bus<br />

UNT<br />

AHU/VAV/<br />

UNT/DX<br />

NCM350/361<br />

Notes: 1. Only models NCM300-2 <strong>and</strong><br />

NCM350-2 are Listed for UL 864<br />

smoke control applications.<br />

2. Up to eight total <strong>XTM</strong>-<strong>905</strong> <strong>and</strong><br />

XT-9100 extension modules per<br />

XT Bus.<br />

XT-9100/XP910x<br />

<strong>XTM</strong>-<strong>905</strong>/<strong>XPx</strong><br />

Ncmap<br />

Figure 2: Metasys Network Control Module (NCM) Application<br />

Operator<br />

Terminal<br />

N30<br />

N2 Bus<br />

XT Bus<br />

DX-9100<br />

UNT<br />

VAV<br />

<strong>XTM</strong>-<strong>105</strong>/<strong>XPx</strong><br />

<strong>XTM</strong>-<strong>905</strong>/<strong>XPx</strong><br />

N30app<br />

Figure 3: Metasys N30 Application<br />

2 Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong>


I ntroduction<br />

The <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong>, used with the <strong>XPx</strong><br />

expansion modules, are cost-effective devices for<br />

adding control points to the Building Automation<br />

System (BAS). This line of point extension <strong>and</strong><br />

expansion modules combines the functions of<br />

signal conditioners, relays, <strong>and</strong> manual overrides<br />

for controlling building operation. These modules<br />

simplify the selection of point types <strong>and</strong> provide<br />

greater functionality. The <strong>XTM</strong>-<strong>105</strong> can support<br />

8 Analog Input/Output (AI/AO) points <strong>and</strong><br />

32 Binary Input/Output (BI/BO) points, or 40 BI/BO<br />

points. The <strong>XTM</strong>-<strong>905</strong> can support 8 AI/AO points <strong>and</strong><br />

8 BI/BO points, or 16 BI/BO points.<br />

Modular Flexibility<br />

The <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> are designed for use<br />

in a variety of applications. These modules feature:<br />

• Voltage, current, <strong>and</strong> resistance options:<br />

analog input/output types 0-10V, 0/4-20 mA,<br />

5K ohm potentiometer, <strong>and</strong> passive<br />

Resistance Temperature Device (RTD)<br />

sensors:<br />

- Nickel (Ni) 1000 Regular (JCI)<br />

- Ni 1000 High Temperature (JCI)<br />

- Platinum (Pt) 1000 (DIN)<br />

- A99 (JCI)<br />

• Binary Output options: magnetic <strong>and</strong> electric<br />

latching relays for safe <strong>and</strong> efficient power<br />

restoration. Interlocked <strong>and</strong> staged relays for<br />

multispeed fan control.<br />

• BI counters for one or two <strong>XPx</strong> modules<br />

(when no analog modules are installed.<br />

Limited to eight maximum inputs.<br />

• Module designs that conform to DIN<br />

st<strong>and</strong>ards, allowing access to indicator lamps<br />

<strong>and</strong> controls, <strong>and</strong> providing protection from the<br />

internal wiring when mounted in st<strong>and</strong>ard DIN<br />

cabinets. Easy to retrofit existing devices.<br />

• Accumulator function applications support<br />

monitoring of devices that provide pulse<br />

outputs.<br />

Reliable Operation<br />

To reduce the possibility of equipment<br />

malfunctions or damage, the <strong>XTM</strong>-<strong>105</strong> <strong>and</strong><br />

<strong>XTM</strong>-<strong>905</strong> include the following features:<br />

• Durable case protects against physical<br />

damage <strong>and</strong> electrostatic discharge.<br />

• <strong>XPx</strong> debounce filter helps prevent false<br />

alarms or erroneous counts in accumulator<br />

points.<br />

• Self-checking diagnostics provide reliable<br />

system operation.<br />

• Cyclic redundancy check in all<br />

communication messages increases immunity<br />

to electromagnetic disturbances.<br />

Easy Installation <strong>and</strong> Maintenance<br />

To make operation of the <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong><br />

more user-friendly, these modules include the<br />

following features:<br />

• Economical way to connect points that are<br />

clustered at a distant location from the NCM<br />

or N30.<br />

• Minimizes the separate hardwiring of each<br />

I/O to the controller.<br />

• Manual override for temporary on-site<br />

adjustments, with LEDs to show point status.<br />

• Fast mounting on DIN rail.<br />

• Windows-based <strong>XTM</strong> Configurator<br />

software for <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> GX Tool software<br />

for <strong>XTM</strong>-<strong>905</strong>:<br />

- configures I/O module layout <strong>and</strong> setup<br />

parameters<br />

- indicates if there is a hardware<br />

configuration incompatibility in the <strong>XTM</strong><br />

after download<br />

- downloads to nine hardware devices via<br />

direct connection or over the network from<br />

the Operator Workstation (OWS)<br />

• LEDs on the module’s front panel display the<br />

status of each corresponding binary (I/O).<br />

Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong> 3


Product Comparison<br />

Table 1 compares the monitoring <strong>and</strong> control<br />

features of the <strong>XPx</strong>-xxx expansion modules.<br />

Table 1: Point Multiplexing Feature Comparison<br />

Product BI BO AI AO Manual<br />

Override<br />

Input<br />

LEDs<br />

Output<br />

LEDs<br />

Triac<br />

Output<br />

Relay<br />

Type<br />

Maximum<br />

Output<br />

Rating**<br />

XPA-821* -- -- 6 2 No No Yes -- -- --<br />

XPB-821 8 -- -- -- No Yes -- -- -- --<br />

XPL-401 4 3-single<br />

stage<br />

XPL-402*** 4 1-single<br />

stage,<br />

1-two<br />

stage<br />

XPL-403*** 4 1-three<br />

stage<br />

XPE-401 4 3-single<br />

stage<br />

XPE-402*** 4 1-single<br />

stage,<br />

1-two<br />

stage<br />

XPE-403*** 4 1-three<br />

stage<br />

-- -- Yes Yes Yes No Magnetic 250 VAC @ 3A<br />

250 VDC @<br />

30W<br />

-- -- Yes Yes Yes No Magnetic 250 VAC @ 3A<br />

250 VDC @<br />

30W<br />

-- -- Yes Yes Yes No Magnetic 250 VAC @ 3A<br />

250 VDC @<br />

30W<br />

-- -- Yes Yes Yes No Electric 250 VAC @ 3A<br />

250 VDC @<br />

30W<br />

-- -- Yes Yes Yes No Electric 250 VAV @ 3A<br />

250 VDC @<br />

30W<br />

-- -- Yes Yes Yes No Electric 250 VAC @ 30A<br />

250 VDC @<br />

30W<br />

XPE-404 4 4 -- -- Yes Yes Yes No Electric 250 VAC @ 1A<br />

250 VDC @<br />

10W<br />

XPT-401 4 4 -- -- Yes Yes Yes Yes -- 24 VAC @ 0.5A<br />

XPT-861 -- 8 -- -- No -- Yes Yes -- 24 VAC @ 0.5A<br />

*XPA-821 has AI types: V, mA, RTD; AO types: VDC, mA<br />

**For all <strong>XPx</strong> modules (except XPT), the maximum current rating at 120 VAC is 3A.<br />

***<strong>XTM</strong>-<strong>105</strong> only.<br />

Note: 25 Hz counters are available on up to eight BIs only when an analog module is not installed.<br />

4 Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong>


Ordering Information<br />

Refer to Tables 2 <strong>and</strong> 3 for <strong>XTM</strong>-<strong>105</strong>,<br />

<strong>XTM</strong>-<strong>905</strong>/<strong>XPx</strong>-xxx <strong>and</strong> accessory model codes.<br />

Table 2: <strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong>/<strong>XPx</strong>-xxx Model Codes<br />

Model Code<br />

<strong>XTM</strong>-<strong>105</strong>-5<br />

<strong>XTM</strong>-<strong>905</strong>-5<br />

XPA-821-5<br />

XPB-821-5<br />

XPL-401-5<br />

XPL-402-5*<br />

XPL-403-5*<br />

XPE-401-5<br />

XPE-402-5*<br />

XPE-403-5*<br />

XPE-404-5<br />

XPT-401-5<br />

XPT-861-5<br />

*<strong>XTM</strong>-<strong>105</strong> only.<br />

Description<br />

<strong>Extension</strong> Module, N2 Communications interface <strong>and</strong> 24 VAC supply<br />

<strong>Extension</strong> Module, XT Bus communication interface <strong>and</strong> 24 VAC supply<br />

Expansion Module Analog, six analog inputs, two analog outputs without manual override<br />

Expansion Module Binary, eight binary inputs<br />

Expansion Module Binary, four binary inputs, three binary outputs<br />

(latching relays with manual override)<br />

Expansion Module Multistate, four binary inputs, one 2-stage output, one binary output<br />

(latching relays with manual override)<br />

Expansion Module Multistate, four binary inputs, one 3-stage output,<br />

(latching relays with manual override)<br />

Expansion Module Binary, four binary inputs, three binary outputs<br />

(electrically maintained relays with manual override)<br />

Expansion Module Multistate, four binary inputs, one 2-stage output, one binary output,<br />

(electrically maintained relays with manual override)<br />

Expansion Module Multistate, four binary inputs, one 3-stage output<br />

(electrically maintained relays manual override)<br />

Expansion Module Binary, four binary inputs, four binary outputs (common supply)<br />

(electrically maintained relays with manual override, software configurable as On/Off or<br />

pulse type)<br />

Expansion Module Binary, four binary inputs, four binary outputs (24 VAC triacs with manual<br />

override)<br />

Expansion Module Binary, eight binary outputs (24 VAC triacs without manual override)<br />

Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong> 5


Table 3: Accessories Model Codes<br />

Model Code<br />

Description<br />

XST-101-0<br />

AS-ENC100-0<br />

EN-EWC10-0<br />

EN-EWC20-0<br />

EN-EWC30-0<br />

EN-EWC40-0<br />

EN-EWC15-0<br />

EN-EWC25-0<br />

EN-EWC35-0<br />

EN-EWC45-0<br />

AS-XFR050-0*<br />

AS-XFR010-1<br />

AS-XFR100-1*<br />

MW-MTOOL-0<br />

50 DIN A4 Sheets of Blank Stickers (12 per sheet) for Module Front Panel<br />

Generic Enclosure Kit, Sheet Metal<br />

Single Enclosure, Plastic Universal Packaging Module (UPM), without Transformer<br />

UPM Dual Unit without Power Components<br />

UPM Triple Unit without Power Components<br />

UPM Quad Unit without Power Components<br />

Single Enclosure, Plastic UPM with 50 VA Transformer<br />

UPM Dual Unit with Power Entry Box <strong>and</strong> 50 VA Power Transformer<br />

UPM Triple Unit with Power Entry Box <strong>and</strong> 100 VA Power Transformer<br />

UPM Quad Unit with Power Entry Box <strong>and</strong> 100 VA Power Transformer<br />

50 VA Transformer, Split Bobbin<br />

100 VA Transformer, 120 VAC with Circuit Breaker, Split Bobbin,<br />

UL® (Underwriters Laboratories) Recognized Class 2<br />

100 VA Transformer Kit, 120 VAC with Circuit Breaker, Split Bobbin<br />

M-Tool Package includes GX Tool Software <strong>and</strong> <strong>XTM</strong> Configurator software.<br />

MW-MTOOL-6 M-Tool Software Upgrade (The package upgrades customers from Configuration Tools to<br />

M-Tool.)<br />

*These are the only transformers approved for UL 864 smoke control applications. Any UL Recognized, Class 2<br />

transformer may be used in UL 916 energy management applications.<br />

6 Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong>


Notes<br />

Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong> 7


S pecifications Product<br />

Ambient Operating<br />

Conditions<br />

Ambient Storage<br />

Conditions<br />

Dimensions (H x W x D)<br />

Shipping Weight<br />

<strong>XTM</strong>-<strong>105</strong> <strong>Extension</strong> Module<br />

<strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> Module<br />

<strong>XPx</strong>-xxx-x Expansion <strong>Modules</strong><br />

+0 to + 50°C (+32 to +122°F)<br />

10–90% RH<br />

-40 to + 70°C (-40 to 158°F)<br />

118 x 70 x 57 mm (4.65 x 2.76 x 2.25 in.)<br />

<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong>, 150g (5.3 oz)<br />

XPA-821-5, 237g (8.4 oz)<br />

Other expansion modules (<strong>XPx</strong>-xxx-x) 163g (5.8 oz)<br />

Agency Listings UL Listed, CSA Certified, CE Mark Compliant, FCC Compliant<br />

Note: The <strong>XTM</strong>/<strong>XPx</strong> products are UL 864 Listed for smoke control (UUKL) with<br />

a complimentary UL Listing for Energy Management (PAZX). To comply<br />

with UL UUKL requirements for smoke control applications, all devices<br />

on the communication buses must be UL UUKL Listed. When the<br />

<strong>XTM</strong>/<strong>XPx</strong> products are connected to N30 or NCM 350 devices, the<br />

system will comply with the UL 916 PAZX Listing for Energy<br />

Management only. For details on smoke control applications, refer to the<br />

Smoke Control Technical Bulletin (LIT-636330) located in the Metasys<br />

Network Technical Manual (FAN 636) under the Smoke Control major<br />

tab.<br />

The performance specifications are nominal <strong>and</strong> conform to accepted industry st<strong>and</strong>ards. For applications at conditions beyond<br />

these specifications, consult the local Johnson Controls office. Johnson Controls shall not be liable for damages resulting from<br />

misapplication or misuse of its products.<br />

Controls Group<br />

www.johnsoncontrols.com<br />

507 E. Michigan Street FAN 635<br />

P.O. Box 423<br />

Metasys Network Sales Resource Manual<br />

Milwaukee, WI 53201<br />

Printed in U.S.A.<br />

8 Application Specific Controllers—<strong>XTM</strong>-<strong>105</strong> <strong>and</strong> <strong>XTM</strong>-<strong>905</strong> <strong>Extension</strong> <strong>Modules</strong>, <strong>XPx</strong> Expansion <strong>Modules</strong>