<strong>BTC</strong> TANK TYPE HEATERS<br />

SERVICE WORKBOOK<br />

STEP 7. THERMOSTAT TEST. Set the thermostat to call for heat. Using your multimeter,<br />

test for 24 VAC between right terminal and ground.<br />

- If the meter does not read 24 VAC and the jumper wire between the high limit and<br />

the thermostat is in place, replace the thermostat.<br />

- If the meter reads 24 VAC, go to Step 8.<br />

Note: If the high limit to thermostat jumper wire was disconnected earlier to simulate a satisfied thermostat,<br />

reconnect the jumper to the terminals.<br />

Note: A yellow wire from this thermostat terminal connects to the damper PC board.<br />