<strong>BTC</strong> TANK TYPE HEATERS<br />
SERVICE WORKBOOK<br />
STEP 7. THERMOSTAT TEST. Set the thermostat to call for heat. Using your multimeter,<br />
test for 24 VAC between right terminal and ground.<br />
- If the meter does not read 24 VAC and the jumper wire between the high limit and<br />
the thermostat is in place, replace the thermostat.<br />
- If the meter reads 24 VAC, go to Step 8.<br />
Note: If the high limit to thermostat jumper wire was disconnected earlier to simulate a satisfied thermostat,<br />
reconnect the jumper to the terminals.<br />
Note: A yellow wire from this thermostat terminal connects to the damper PC board.<br />
A.O. <strong>Smith</strong> <strong>Water</strong> Products<br />