<strong>BTC</strong> TANK TYPE HEATERS<br />

SERVICE WORKBOOK<br />

STEP 11. WIRE HARNESS TEST. Test for 24 VAC between terminal 24V on the IID module,<br />

and 24V (GND).<br />

- If 24 VAC is not present, check the wiring harness.<br />

- If 24 VAC is present, reconnect the red wire to terminal 24V on the IID module and<br />

go to Step 12.<br />

Note: This test may be easier to conduct by removing the red wire from the IID terminal. Test for 24 VAC<br />

between the red wire and ground. Reconnect the red wire to the 24V terminal after the test.<br />