<strong>BTC</strong> TANK TYPE HEATERS<br />

SERVICE WORKBOOK<br />

Pilot is lit - Sparking has stopped.<br />

STEP 17. IID MODULE TEST. Using a multimeter, test for 24 VAC between terminal MV on<br />

the IID and 24V (GND).<br />

- If 24 VAC is not present, replace the IID module. Conduct Step 18 before applying<br />

power to replacement module.<br />

- If 24 VAC is present, go to Step 18.<br />

A.O. <strong>Smith</strong> <strong>Water</strong> Products<br />

Irving, Texas ©1998<br />

37<br />

Service Workbook<br />

Training Department