Finepitch fixture<br />

with rigid probes<br />

For various test systems<br />

→ agilent<br />

→ Teradyne<br />

→ Digitaltest<br />

→ spea<br />

→ aeroflex<br />

→ and others<br />

At test fixtures with rigid probes, the<br />

fine pitch of the DUT is transferred to a<br />

standard pitch of 2,54 mm. This is realised<br />

by tangential deviation of the rigid<br />

probes up to 6 degree.<br />

The rigid probe test head is assembled on<br />

top of any standard vacuum fixture kit<br />

and is applicable for all test systems.<br />

Special features<br />

→ fine pitch down to 30 mil, feasible for larger area<br />

→ easy replacement of rigid probes<br />

→ contacting via vacuum hood<br />

→ cost efficient for large number of test points with centers ≤50mil<br />

→ for wired component contacting rigid probes with tip style 06<br />

(Serrated Head) and 14 (4-Point Crown Head) are available.<br />

→ possible to contact on both sides<br />

→ special data generation for Agilent 3070 possible<br />

Finepitch-Fixture (0,3 mm needles)<br />

Minimum distance mm mil Recommended Dimension*<br />

<strong>Test</strong> point - test point 0,50 20 A<br />

<strong>Test</strong> point - component (smaller 3 mm) 0,50 20 min 0,8 mm B<br />

<strong>Test</strong> point - component (higher 3 mm) 0,76 30 B<br />

Diameter centering hole tolerance ±0,05 ±2<br />

<strong>Test</strong> point - centering hole 0,50 ±0,03 20 min 0,8 mm D<br />

<strong>Test</strong> point to board edge 0,3 12 E<br />

Minimum test point size 0,35 14 F<br />

Finepitch-Fixture (0,5 mm needles)<br />

Minimum distance mm mil Recommended Dimension*<br />

<strong>Test</strong> point - test point 0,76 30 A<br />

<strong>Test</strong> point - component (smaller 3 mm) 0,76 30 min 1,0 mm B<br />

<strong>Test</strong> point - component (higher 3 mm) 1,0 40 B<br />

Diameter centering hole tolerance ±0,05 ±2<br />

<strong>Test</strong> point - centering hole 0,76 ±0,05 30 min 1,0 mm D<br />

<strong>Test</strong> point - board edge 0,3 12 E<br />

Minimum test point size 0,4 15 0,6 F<br />

* see drawing on page 5<br />