You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
8 · <strong>VAS</strong>, <strong>VCS</strong> · Edition 07.09<br />
Selection<br />
Selection table <strong>VAS</strong> 1 – 3<br />
Accessories right<br />
Accessories left<br />
M20-cable gland<br />
Plug with socket<br />
Plug without socket<br />
Screw plug<br />
Pressure test point<br />
DG 17VC 2)<br />
DG 40VC 2)<br />
DG 110VC 2)<br />
DG 300VC 2)<br />
Bypass valve VBY<br />
Bypass valve <strong>VAS</strong> 1<br />
Screw plug<br />
Pressure test point<br />
DG 17VC 2)<br />
DG 40VC 2)<br />
DG 110VC 2)<br />
DG 300VC 2)<br />
Bypass valve VBY<br />
Bypass valve <strong>VAS</strong> 1<br />
Type T R N F /N /L K P Q Y W S 1) G 1) R 1) L 1)<br />
<strong>VAS</strong> 1 – – – <br />
<strong>VAS</strong> 1-0 – – – <br />
<strong>VAS</strong> 110 – <br />
<strong>VAS</strong> 115 – <br />
<strong>VAS</strong> 120 – <br />
<strong>VAS</strong> 125 – <br />
<strong>VAS</strong> 2 – – – – – <br />
<strong>VAS</strong> 225 – – – <br />
<strong>VAS</strong> 232 – – – <br />
<strong>VAS</strong> 240 – – <br />
<strong>VAS</strong> 250 – – – <br />
<strong>VAS</strong> 3 – – – – – <br />
<strong>VAS</strong> 340 – – – <br />
<strong>VAS</strong> 350 – – <br />
<strong>VAS</strong> 365 – – – <br />
= standard, = available<br />
1) Position indicator and bypass /pilot gas valve cannot be fi tted together on the same side.<br />
2) Specify the test point for inlet pressure p e or outlet pressure p a .<br />
Help for dimensioning and confi guring the gas solenoid valve <strong>VAS</strong> can be found in the program “Product Selection”<br />
on the Catalogue DVD. You can order the Catalogue DVD at<br />
www.kromschroeder.com <strong>Products</strong> CD-ROMs Catalogue.<br />
Order example<br />
<strong>VAS</strong> 225R/NW<br />
Fitted pressure<br />
switch for test<br />
point p e<br />
Type code <strong>VAS</strong> 1– 3<br />
Code<br />
Description<br />
<strong>VAS</strong><br />
Gas solenoid valve<br />
1 – 3 Size<br />
T<br />
T product<br />
–<br />
no inlet- and no outlet fl ange<br />
-0<br />
blind fl ange<br />
10 – 65<br />
Nominal inlet and outlet diameter<br />
R<br />
N<br />
F<br />
/N<br />
/L<br />
K<br />
P<br />
Q<br />
Y<br />
W<br />
S<br />
G<br />
R<br />
L<br />
Rp internal thread<br />
NPT internal thread<br />
ISO fl ange<br />
quick opening, quick closing<br />
slow opening, quick closing<br />
Mains voltage 24 V DC<br />
Mains voltage 100 V AC; 50/60 Hz<br />
Mains voltage 120 V AC; 50/60 Hz<br />
Mains voltage 200 V AC; 50/60 Hz<br />
Mains voltage 230 V AC; 50/60 Hz<br />
Position indicator with visual indicator<br />
Position indicator for 24 V with visual indicator<br />
Viewed from the right (in the direction of fl ow)<br />
Viewed from the left (in the direction of fl ow)