<strong>TC35i</strong> AT Command Set<br />

Confidential / Released<br />

2.45 AT+IFC Set Flow Control separately for data directions<br />

The command AT+IFC can be used to set or query the type of flow control separately for each data<br />

direction.<br />

Test command<br />

AT+IFC=?<br />

The Test command returns the values of the supported methods of flow control.<br />

Response<br />

+IFC: (list of supported s), (list of supported s)<br />

OK<br />

Parameter<br />

See write command<br />

Read command<br />

AT+IFC?<br />

Write command<br />

AT+IFC=<br />

,<br />

<br />

The Read command returns the currently selected method of flow control.<br />

Response<br />

+IFC: , OK<br />

Parameter<br />

See write command<br />

The parameter setting determines the data flow control on the serial interface.<br />

Response<br />

OK<br />

ERROR<br />

Parameter<br />

(numeric)<br />

Specifies the method that will be used by the TE when data is received<br />

from the TA.<br />

[0] none<br />

1 XON/XOFF. Terminate flow control in the cellular engine.<br />

2 RTS line<br />

3 XON/XOFF. Evaluate flow control in the cellular engine and<br />

pass it through (over the air) to the opposite TE.<br />

(numeric)<br />

Specifies the method that will be used by the TA when data is received<br />

from the TE.<br />

[0] none<br />

1 XON/XOFF<br />

2 CTS line<br />

Reference<br />

V.25ter<br />

Note<br />

The setting of AT+IFC is stored volatile. For use after restart it should be<br />

stored to the user defined profile (AT&W).<br />

The type of flow control set with AT\Qn is valid in both data directions. See<br />

Chapter 2.3.<br />

When using XON/XOFF flow control ( AT+IFC =1,x or AT+IFC =3,x) in data<br />

mode, +++ should not be used while the data transmission is paused with<br />

XOFF. Before entering the command mode with +++ the paused transmission<br />

should be resumed using the XON character.<br />