Installation and connection<br />

1 x 230/265 V 50/60 Hz<br />

Various connection options for different mains power supplies.<br />

Motor junction box<br />

3 x 230 V 50 Hz<br />

3 x 265 V 60 Hz<br />

3 x 400 V 50 Hz<br />

3 x 460 V 60 Hz<br />

Key to Fig. 9<br />

B1 Pressure switch PS 114<br />

B2 Limit switch, coil temperature<br />

B3 Flow monitor (fan)<br />

K1 Relay for fan motor<br />

K2 Relay for temperature monitor<br />

K3 Relay for <strong>Roots</strong> pump motor<br />

K4 Relay for fan monitor<br />

N1 Contact amplifier SV 110 (220 V - 240 V,<br />

50/60 Hz, 110 - 130 V, 50/60 Hz)<br />

S1 External switch contact<br />

S2 Switch contact<br />

F1 Fuse, control circuit<br />

Q1 Motor protection switch<br />

Signal lamps<br />

H1 Motor protection switch: OFF<br />

H2 <strong>Roots</strong> pump: ON<br />

H3 Coil temperature: TOO HIGH<br />

H4 Cooling air: BELOW MINIMUM<br />

Links<br />

BR on extension : - - remove link<br />

Note<br />

The above control circuit is designed so that the<br />

<strong>Roots</strong> pump cuts in only if the pressure drops below<br />

the set pressure level (B1).<br />

Fig. 9 Electrical connection<br />

GA 03.108/7.02 - 11/96<br />