2. Unit Identification<br />
This unit can be correctly identified by the<br />
technical name-plate containing all the<br />
information for its correct use.<br />
In addition to the manufacturer's identification<br />
data and the product trade-marks, the nameplate<br />
contains the following information:<br />
The technical name-plate is embossed on a<br />
plastic support which ensures high endurance<br />
of the text even in particularly difficult<br />
environments.<br />
N.B. For any assistance or information<br />
concerning the unit described in this manual,<br />
knowledge of its serial number is essential.<br />
Constructor<br />
Model<br />
Series<br />
Date<br />
Nominal voltage<br />
Control voltage<br />
Phase<br />
Frequency<br />
Trademark<br />
This identifies the product family.<br />
Product identification number.<br />
Date on which the product is placed<br />
on the market and date of<br />
commencement of warranty.<br />
Voltage to be supplied to the unit<br />
Working voltage of the auxiliary<br />
circuits if different from the voltage<br />
rating.<br />
Voltage phase<br />
Voltage frequency.<br />
Start/Run current<br />
Current absorbed when starting the compressor. /<br />
Current absorbed during operation at the permitted<br />
maximum temperature<br />
Cooling capacity<br />
Unit cooling capacity with 35°C inside cabinet<br />
temperature and 35°C ambient temperature conditions.<br />
Power absorbed<br />
Power absorbed by the unit with 35°C inside cabinet<br />
temperature and 50°C ambient temperature conditions.<br />
Automatic circuit breaker curve type C, Safety<br />
fuse type aM<br />
Rating of the automatic switch/safety fuse to be installed<br />
by the installer.<br />
Inside temperature<br />
Minimum and maximum cabinet temperature where the<br />
machine works and for which the machine was<br />
designed.<br />
Outside temperature<br />
Minimum and maximum ambient temperature where<br />
the machine works and for which the machine was<br />
designed<br />
Refrigerant charge<br />
Quantity of refrigerant contained in the unit's<br />
refrigeration circuit<br />
Type of refrigerant<br />
Brand name of the refrigerant used in the unit's cooling<br />
circuit<br />
Maximum pressure<br />
Maximum pressure at which the refrigeration circuit<br />
functions<br />
Cabinet side protection IP<br />
protection level in the direction of the cabinet<br />
Ambient side protection IP<br />
protection level in the direction of the ambient<br />
Weight Empty weight of the machine<br />
Duty Cycle Operational capacity of the unit<br />
E/0304/31A/15