2. Unit Identification<br />

This unit can be correctly identified by the<br />

technical name-plate containing all the<br />

information for its correct use.<br />

In addition to the manufacturer's identification<br />

data and the product trade-marks, the nameplate<br />

contains the following information:<br />

The technical name-plate is embossed on a<br />

plastic support which ensures high endurance<br />

of the text even in particularly difficult<br />

environments.<br />

N.B. For any assistance or information<br />

concerning the unit described in this manual,<br />

knowledge of its serial number is essential.<br />

Constructor<br />

Model<br />

Series<br />

Date<br />

Nominal voltage<br />

Control voltage<br />

Phase<br />

Frequency<br />

Trademark<br />

This identifies the product family.<br />

Product identification number.<br />

Date on which the product is placed<br />

on the market and date of<br />

commencement of warranty.<br />

Voltage to be supplied to the unit<br />

Working voltage of the auxiliary<br />

circuits if different from the voltage<br />

rating.<br />

Voltage phase<br />

Voltage frequency.<br />

Start/Run current<br />

Current absorbed when starting the compressor. /<br />

Current absorbed during operation at the permitted<br />

maximum temperature<br />

Cooling capacity<br />

Unit cooling capacity with 35°C inside cabinet<br />

temperature and 35°C ambient temperature conditions.<br />

Power absorbed<br />

Power absorbed by the unit with 35°C inside cabinet<br />

temperature and 50°C ambient temperature conditions.<br />

Automatic circuit breaker curve type C, Safety<br />

fuse type aM<br />

Rating of the automatic switch/safety fuse to be installed<br />

by the installer.<br />

Inside temperature<br />

Minimum and maximum cabinet temperature where the<br />

machine works and for which the machine was<br />

designed.<br />

Outside temperature<br />

Minimum and maximum ambient temperature where<br />

the machine works and for which the machine was<br />

designed<br />

Refrigerant charge<br />

Quantity of refrigerant contained in the unit's<br />

refrigeration circuit<br />

Type of refrigerant<br />

Brand name of the refrigerant used in the unit's cooling<br />

circuit<br />

Maximum pressure<br />

Maximum pressure at which the refrigeration circuit<br />

functions<br />

Cabinet side protection IP<br />

protection level in the direction of the cabinet<br />

Ambient side protection IP<br />

protection level in the direction of the ambient<br />

Weight Empty weight of the machine<br />

Duty Cycle Operational capacity of the unit<br />