Connection codes / Special designs<br />

<strong>zehnder</strong> <strong>charleston</strong> bank<br />

Standard connection codes (no additional cost) for <strong>zehnder</strong> <strong>charleston</strong> bank radiators<br />

If the connection method is not specified in the order, the radiator will be supplied with bottom down, 3 x 1 /2” connection.<br />

The following standard connection options are possible:<br />

1/2"L<br />

L1/2"<br />

243<br />

423<br />

1/2"<br />

1/2"<br />

1/2"<br />

1/2"<br />

V<br />

R<br />

R<br />

V<br />

Special connection modes for <strong>zehnder</strong> <strong>charleston</strong> bank radiator<br />

When placing the order, it is necessary to show the connection number (Nr.) and dimensions<br />

same-side<br />

V<br />

R<br />

1 3 L<br />

120<br />

2<br />

4<br />

L 1 3<br />

340<br />

2<br />

4<br />

V<br />

R<br />

opposite-end<br />

L 1 3 R<br />

230<br />

V 2<br />

4 E<br />

R 1 3 L<br />

410<br />

E 2<br />

4 V<br />

V<br />

1 3 L<br />

240<br />

2<br />

4 R<br />

L 1 3<br />

420<br />

R 2<br />

4<br />

V<br />

V<br />

1 3 L<br />

140<br />

2<br />

4 R<br />

L 1 3<br />

320<br />

R 2<br />

4<br />

V<br />

vertically underneath<br />

1 3 L<br />

223<br />

2<br />

4<br />

V R<br />

L 1 3<br />

443<br />

2<br />

4<br />

R V<br />

no additional cost<br />

for monotube valve*,<br />

horizontal<br />

1 3 L<br />

V/R 20<br />

2<br />

4<br />

L 1 3<br />

40 V/R<br />

2<br />

4<br />

for monotube valve*,<br />

vertical<br />

1 3 L<br />

23<br />

2<br />

4<br />

V/R<br />

L 1 3<br />

43<br />

2<br />

4<br />

V/R<br />

V = flow, R = return, L = air vent, E = water drain, B = blind plug, O = buffle (standard), • = buffle (100% watertight)<br />

*when placing the order, it is necessary to show information about the valve manufacturer<br />

Angled models<br />

Ability to manufacture angled models: from 90° to 179°. When requesting<br />

pricing, it is necessary to provide drawings with the following<br />

dimensions: dimensions A, B, C and distance to wall WA in<br />

mm, angles · & ‚ in degrees. Templates submitted at order stage<br />

cannot be changed.<br />

Curved models<br />

R<br />

B<br />

B<br />

90 < AB<br />

R<br />

A<br />

A<br />

B<br />

90<br />

inside radius<br />

outside radius<br />

< AB<br />

< AB<br />

A<br />

inside angle 90° inside angle<br />

outside angle 90°<br />

from 90° to 179°<br />

Zehnder Charleston radiators can be produced in curved designs<br />

with radius not less than:<br />

< AB<br />

C<br />

B<br />

< AB < AC<br />

for 4-column models: 750 mm<br />

for 5-column models: 900 mm<br />

for 6-column models: 1000 mm<br />

B<br />

outside angle<br />

from 90° to 179°<br />

A<br />

< BC < AB<br />

double inside angle<br />

from 90° to 179°<br />

A<br />

B<br />

double outside angle<br />

from 90° to 179°<br />

A<br />

C<br />

When requesting pricing, it is necessary to provide drawings<br />

with the following dimensions:<br />

radius R, length, and distance to wall in mm. Templates submitted<br />

at order stage cannot be changed.<br />