Figure 25: Distribution of the median seeing over the Wide tiles. The seeing is the FWHM= √ a b derived with<br />

PSFEX, from the fitting of a 2-dimension Moffat model of the PSF. The mean seeing value over the MegaCam field<br />

of each stack is available at http://terapix.iap.fr/cplt/T0007/table_syn_T0007.html.<br />

is observed, the median seeing of each stack appears randomly distributed over the four Wide fields.<br />

Figure 27 shows the seeing fluctuations on MegaCam. The seeing is averaged over a CCD field of view<br />

and compared to the mean seeing over the whole MegaCam field. The statistics is based on 6378 input<br />

images used for the CFHTLS Wide T0007 release. For CCDs at the edges of the detector, the differences<br />

are important but never exceed 0.065", and the maximum peak-to-peak amplitude is less than 0.1" . This<br />

upper limit is acceptable. It still preserves the mean seeing over the whole MegaCam field of view below<br />

one arcsecond for all input images that will be combined into stacks. The legend of Figure 27 elaborates<br />

on the extreme corners of the MegaCam field of view which exhibit a rapid image quality degradation,<br />

but represent an area limited to just 3% of each image.<br />

38