<strong>Barstow</strong> <strong>Community</strong> <strong>College</strong> <strong>Facilities</strong> <strong>Master</strong> <strong>Plan</strong><br />

// Background & Existing Conditions Summary<br />

Electrical Systems<br />

The newer (post 1996) buildings have electrical systems that are current with the<br />

code requirements of Title 24 of the California Administrative Code (State Building<br />

Code). The older buildings have functional, serviceable electrical systems that,<br />

in all probability, need updating to meet current code requirements. As these<br />

facilities are modernized, the attendant electrical systems should be brought<br />

into code compliance.<br />

Plumbing Systems<br />

The plumbing systems appear to be in functional, serviceable condition<br />

throughout the campus. Many of the toilet facilities have been upgraded over<br />

time to meet the requirements of Title 24 of the C.A.C. and the Americans with<br />

Disabilities Act (ADA).<br />

Fire Protection<br />

The following buildings are not equipped with an Automatic Fire<br />

Sprinkler (AFS) system:<br />

•§<br />

Administration Building (A Building, Building No. 01)<br />

•§<br />

Classroom Building (S Building, Building No. 3)<br />

•§<br />

Fitness Center (F Building, Building No. 04)<br />

•§<br />

Warehouse (W Building, Building No. 05)<br />

•§<br />

Classroom Building (T Building, Building No. 6)<br />

•§<br />

Gymnasium (G Building, Building No. 07)<br />

•§<br />

Classroom Building (B Building, Building No. 8)<br />

•§<br />

Performing Arts Building (K Building, Building No. 09)<br />

•§<br />

Classroom Building (D Building, Building No. 11)<br />

There exists a campus-wide Fire Alarm System that has been recently upgraded<br />

and is presently centrally monitored; however does not fully meet accessibility<br />

requirements.<br />

Information Technology<br />

The Data Center is located in the Administration Building. The campus is served<br />

by a fiber optic loop that is presently adequate to service the campus and<br />

accommodate future expansion for the foreseeable future. The campus wireless<br />

system has nodes that require upgrade, but is considered to be capable of being<br />

managed with current budgets. Growth of wireless access is considered slow.<br />

Communication<br />

The telephone system core has been recently upgraded and capable of handling<br />

campus needs for the foreseeable future.<br />

Security<br />

The campus security system has been recently upgraded. Consideration is being<br />

given to expanding the card access.<br />

Signage and Wayfinding<br />

As a general statement, signage throughout the campus does not meet accessibility<br />

requirements.<br />

There are two campus directories located in the vicinity of the Learning Center.<br />

There is no signage along the various pathways indicating either accessible paths<br />

of travel or offering direction to campus facilities.<br />

Accessibility<br />

The 2011 <strong>Facilities</strong> Program discusses a campus-wide survey of Accessibility<br />

issues on a macro level as well as delineating a program to implement an<br />

Accessibility Transition <strong>Plan</strong>.<br />