<strong>Triax</strong> TMM 5x series<br />

cascadable multiswitches<br />

TMM 5x multiswitches<br />

• 4 satellite polarities and 1 terestrial input,<br />

combined output.<br />

• Versions for 8, 12 and 16 subscriber outputs<br />

• Adjustable attenuator per polarity (0-12 dB)<br />

• Low power consumption<br />

• Small footprint, compact design, fits into tight<br />

spaces<br />

• 2-, 3- and 4-way DiSEqC bridger units with<br />

TER loop-through<br />

• Wide range of launch and line amplifiers available<br />

TMM 5x series<br />

Technical data - Cascadable - 4 polarities and 1 terrestrial. Ext. power supply<br />

TYPE<br />

TMM 5x4<br />

TMM 5x8<br />

TMM 5x12<br />

TMM 5x16<br />

TMM 5x12T<br />

Art. No.<br />

305314 305318 305312 305316 305317<br />

Number of inputs 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER<br />

Number of trunk outputs 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER 4 SAT, 1 TER<br />

Subscriber outputs 4 8 12 16 12<br />

Connectors F-con F-female F-female F-female F-female F-female<br />

Frequency range MHz 950-2150 950-2150 950-2150 950-2150 950-2150<br />

Through loss (trunk TER) dB 1.5 2.5 3.0 3.0<br />

Through loss (trunk SAT) dB 1.5 2.5 2.5 2.5<br />

Tap loss - TER dB 10 10 12 12 5<br />

Tap loss - SAT dB 10 10 12 12 5<br />

Input polarity gain control - TER dB 12 12 12 12 12<br />

Input polarity gain control - SAT dB 4 x 12 4 x 12 4 x 12 4 x 12 4 x 12<br />

Isolation TER to SAT dB 35 35 30 30 30<br />

Isolation SAT to TER dB 35 35 30 30 30<br />

Isolation cross polarisation H/V dB 30 30 28 28 28<br />

Isolation out - out TER dB 30 30 30 30 30<br />

Isolation out - out SAT dB 30 30 30 30 30<br />

Return loss TER inputs dB 12 12 12 12 12<br />

Return loss TER outputs dB 12 12 12 12<br />

Return loss SAT inputs dB 12 12 12 12 12<br />

Return loss SAT outputs dB 12 12 12 12<br />

Return loss switch out - TER dB 10 10 10 10 12<br />

Return loss switch out - SAT dB 10 10 10 10 12<br />

Max. input level<br />

TER (IMA3 / -60 dB) dBµV 110<br />

107<br />

109<br />

109<br />

102<br />

SAT (IMA3 / -35 dB) dBµV 117<br />

117<br />

119<br />

119<br />

112<br />

Max. output level<br />

TER (IMA3 / -60 dB) dBµV 88<br />

88<br />

88<br />

88<br />

88<br />

SAT (IMA3 / -35 dB) dBµV 95<br />

95<br />

95<br />

95<br />

95<br />

Line power<br />

Voltage (Switched TER) V 12<br />

12<br />

12<br />

12<br />

12<br />

Current (Switched TER) mA 50<br />

50<br />

50<br />

50<br />

50<br />

Switching commands<br />

VDC/<br />

kHz<br />

13V / 18V<br />

13V - 22 kHz / 18 - 22 kHz, DiSEqC 2.0<br />

Switching voltage V 15 /±1V 15 /±1V 15 /±1V 15 /±1V 15 /±1V<br />

TER current<br />

(supplied from TER trunkline) mA 50 50 50 50 50<br />

Max. current of each output<br />

(supplied by satellite receiver) mA < 150 < 150 < 150 < 150 < 150<br />

Temperature range o C 0 - 50 0 - 50 0 - 50 0 - 50 0 - 50<br />