Input<br />

RC output<br />

Equalizer<br />

0-15 dB<br />

Rotary switch.<br />

Attenuator<br />

0-15 dB<br />

Rotary switch<br />

HP<br />

LP<br />

Diplex-Filter<br />

switchable<br />

Test 1, -20dB<br />

Bi-directional<br />

Attenuator<br />

0/6 dB<br />

jumper<br />

Equalizer<br />

0/3/7 dB<br />

jumper<br />

Equalizer Attenuator<br />

0/3/6/9 dB 0/6 dB<br />

jumper jumper<br />

Return path<br />

ON/OFF/Active/Passive<br />

Return path<br />

All-on-board or<br />

plug-in module<br />

RC Gain<br />

25 dB<br />

Attenuator On/Off<br />

0-15 dB Level1/Level2<br />

Rotary sw. jumper<br />

SM Power Supply<br />

190-264 VAC Mains<br />

ARA<br />

HP<br />

LP<br />

Diplex-Filter<br />

switchable<br />

Test 2, -20dB<br />

uni-directional<br />

Output<br />

RC input<br />

Input<br />

RC output<br />

Equalizer<br />

0-15 dB<br />

Rotary switch.<br />

Attenuator<br />

0-15 dB<br />

Rotary switch<br />

HP<br />

LP<br />

Diplex-Filter<br />

switchable<br />

Test 1,-20dB<br />

Bi-directional<br />

Attenuator<br />

0/6 dB<br />

jumper<br />

Equalizer<br />

0/3/7 dB<br />

jumper<br />

Equalizer Attenuator RC Gain Attenuator<br />

0/3/6/9 dB 0/6 dB 22/32 dB 0-15 dB<br />

jumper jumper jumper Rotary sw.<br />

Return path<br />

ON/OFF/Active/Passive<br />

Return path<br />

All-on-board or<br />

plug-in module<br />

SM Power Supply<br />

190-264 VAC Mains<br />

For ARA add-on<br />

module<br />

HP<br />

LP<br />

Diplex-Filter<br />

switchable<br />

Test 2, -20dB<br />

uni-directional<br />

Output<br />

RC input<br />

<strong>Triax</strong> distribution amplifiers<br />

<strong>Triax</strong> GHV 900-series is a low noise coaxial house<br />

distribution amplifier, for use in smaller CATV<br />

distribution networks in multi dwelling houses.<br />

• Optimised 1 GHz technology<br />

• Downstream 20/30/35/40 dB amplification/high output level<br />

• Adjustable attenuation and equalization settings in 1dB<br />

steps using rotary switches and jumpers.<br />

• Switchable VHF band I or 5-65 MHz return path<br />

• Selectable return path: On/Off<br />

• Upstream 25 - 22/32 dB amplification/high output level<br />

• All connectors are F-connector female<br />

• Extensive ESD- and surge-protection<br />

• Low power consumption<br />

Technical data on GHV series<br />

Type<br />

Art No.<br />

Frequency range<br />

Forward path/Forward path w. return on<br />

Return path<br />

Gain forward<br />

Gain @ 1006 MHz<br />

Input attenuator - 1dB step (rotary switch)<br />

Input equalizer - 1dB step (rotary switch)<br />

Interstage attenuator (jumper)<br />

Interstage equalizer (jumper)<br />

Gain return path<br />

Gain @ 60 MHz<br />

Interstage attenuator (jumper)<br />

Interstage equalizer (4 steps/jumper)<br />

Linearity frequency response<br />

@ 47...1006 MHz<br />

@ 85...1006 MHz<br />

@ 5.....65 MHz (return)<br />

Noise figure<br />

Forward<br />

(VHF I „on“)<br />

Return path<br />

(RP „active“)<br />

Return loss @ 40 MHz, -1.5 dB/octave min. Cat C<br />

Forward<br />

Return path<br />

MHz<br />

MHz<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

dB<br />

db<br />

dB<br />

dB<br />

dB<br />

dB<br />

Output level forward<br />

CSO Cenelec 42 ch. 862 MHz, Slope 0/7 dB dBµV<br />

CTB Cenelec 42 ch. 862 MHz, Slope 0/7 dB dBµV<br />

Output level return path<br />

IMR2 acc EN 50083-3<br />

IMR3 acc EN 50083-3<br />

RF connectors (75 Ohm)<br />

Ports<br />

Input / Output<br />

Test point in-/output: uni-directional<br />

Test point return path: bi-directional<br />

dBµV<br />

dBµV<br />

pcs<br />

dB<br />

dB<br />

Block schematic<br />

GHV 920<br />

323150<br />

47-1006/85-1006<br />

5-65<br />

20<br />

0-15<br />

0-15<br />

0/3/7<br />

0/6<br />

22/32<br />

0/6<br />

0/3/6/9<br />

± 1.5<br />

± 1.0<br />

± 1.0<br />

< 7.0<br />

5.5/7.5<br />

> 18<br />

> 18<br />

100<br />

100<br />

104<br />

107<br />

F-con<br />

F-female<br />

-20<br />

-20<br />

Input stage Inter stage Output stages<br />

=<br />

≈<br />

GHV 920 block schema<br />

GHV 930<br />

323158<br />

47-1006/85-1006<br />

5-65<br />

30<br />

0-15<br />

0-15<br />

0/3/7<br />

0/6<br />

22/32<br />

0/6<br />

0/3/6/9<br />

± 1.5<br />

± 1.0<br />

± 1.0<br />

< 7.0<br />

5.5/7.5<br />

> 18<br />

> 18<br />

101<br />

101<br />

104<br />

107<br />

F-con<br />

F-female<br />

-20<br />

-20<br />

Block schematic<br />

GHV 935<br />

323162<br />

Input stage Inter stage Output stages<br />

47-1006/85-1006<br />

5-65<br />

35<br />

0-15<br />

0-15<br />

0/3/7<br />

0/6<br />

22/32<br />

0/6<br />

0/3/6/9<br />

± 1.5<br />

± 1.0<br />

± 1.0<br />

< 7.0<br />

5.5/7.5<br />

> 18<br />

> 18<br />

103<br />

103<br />

104<br />

107<br />

F-con<br />

F-female<br />

-20<br />

-20<br />

=<br />

≈<br />

GHV 940 block schema<br />

GHV 940<br />

323166<br />

47-1006/85-1006<br />

5-65<br />

40<br />

0-15<br />

0-15<br />

0/3/7<br />

0/6<br />

22/32<br />

0/6<br />

0/3/6/9<br />

± 1.5<br />

± 1.0<br />

± 1.0<br />

< 7.0<br />

5.5/7.5<br />

> 18<br />

> 18<br />

108<br />

108<br />

104<br />

107<br />

F-con<br />

F-female<br />

-20<br />

-20<br />

Operating conditions<br />

Power supply voltage (50-60 Hz) V 190-264 190-264 190-264 190-264<br />

Power consumption W < 9 < 9 < 9 < 9<br />

Operating temperature °C -25...+55 -25...+55 -25...+55 -25...+55<br />

Protection class II II II II<br />

Housing protection degree IP 20 20 20 20<br />

Dimensions W x H x D mm 170 x 100 x 65 170 x 100 x 65 170 x 100 x 65 170 x 100 x 65<br />

Weight kg 2.0 2.0 2.0 2.0<br />

Reference standards<br />

Product standards/safety/EMC<br />

RoHS 2002/95/EG compliant<br />

EN 50083-3 - Class 2/EN 50083-1; EN 60065/EN 50083-2<br />

Yes<br />