The 2012 catalogue - Triax
The 2012 catalogue - Triax
The 2012 catalogue - Triax
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Input<br />
Input stage<br />
Attenuator<br />
0-20 dB<br />
Potentiometer<br />
Output stages<br />
Power Supply<br />
230 VAC Mains<br />
Output<br />
Input<br />
Input stage<br />
Attenuator<br />
0-20 dB<br />
Potentiometer<br />
Output stages<br />
Power Supply<br />
230 VAC Mains<br />
Output<br />
<strong>Triax</strong> distribution amplifiers<br />
<strong>Triax</strong> GHV 500-series is a low noise coaxial house<br />
distribution amplifier, for use in small CATV<br />
distribution networks in small building units.<br />
Block schematic<br />
GHV 520 block schema<br />
Block schematic<br />
GHV 530P block schema<br />
• Optimised 1 GHz technology<br />
• Downstream 20/30 dB amplification/high output level<br />
• Adjustable potentiometer or click attenuation<br />
• All connectors are F-connector female<br />
• Without return path possibility<br />
• Extensive ESD- and surge-protection<br />
• Low power consumption<br />
=<br />
≈<br />
=<br />
≈<br />
Technical data on GHV series<br />
Type<br />
Art No.<br />
GHV 520P<br />
323138<br />
GHV 530P<br />
323142<br />
Frequency range<br />
Forward path MHz 40-862 40-862<br />
Gain forward<br />
Gain @ 1006 MHz<br />
Gain low/hi jumper<br />
Input attenuator - 1dB step (rotary switch)<br />
dB<br />
dB<br />
dB<br />
21<br />
0-20 (pot.)<br />
30<br />
0-20 (pot.)<br />
Linearity frequency response<br />
@ 47...1006 MH dB ± 1.0 ± 1.0<br />
Noise figure<br />
Forward dB < 7.0 < 7.0<br />
Return loss (@ 40 MHz, -1.5 dB/octave min. 12 dB)<br />
Forward dB > 18 > 18<br />
Output level forward<br />
CSO Cenelec 42 ch.<br />
CTB Cenelec 42 ch.<br />
RF connectors (75 Ohm)<br />
Ports<br />
Input / Output<br />
Test point in-/output: uni-directional<br />
Test point return path: bi-directional<br />
dBµV<br />
dBµV<br />
pcs<br />
dB<br />
dB<br />
101<br />
101<br />
F-con<br />
F-female<br />
-20<br />
101<br />
101<br />
F-con<br />
F-female<br />
-20<br />
Operating conditions<br />
Power supply voltage (50-60 Hz) V 230 230<br />
Power consumption W < 3 < 3<br />
Operating temperature °C -25...+55 -25...+55<br />
Protection class II II<br />
Housing protection degree IP 20 20<br />
Dimensions W x H x D mm 170 x 100 x 65 170 x 100 x 65<br />
Weight kg 2.0 2.0<br />
Reference standards<br />
Product standards/safety/EMC<br />
RoHS 2002/95/EG compliant<br />
EN 50083-3 - Class 2/EN 50083-1; EN 60065/EN 50083-2<br />
Yes<br />