Nomenclature · Selection of nominal size<br />
Nomenclature<br />
fm<br />
in Hz : Octave band centre frequency<br />
LPA in dB(A) : A-weighted sound pressure level of<br />
air-regenerated noise, system<br />
attenuation taken into account<br />
LPA₁ in dB(A) : A-weighted sound pressure level of<br />
air-regenerated noise in the room with<br />
CS circular silencer, system attenuation<br />
taken into account<br />
LPA₂ in dB(A) : A-weighted sound pressure level of<br />
case-radiated noise, system attenuation<br />
taken into account<br />
LW<br />
in dB : Sound power level of the air-regenerated<br />
noise in the duct<br />
LW₂<br />
in dB : Sound power level of the case-radiated<br />
noise<br />
V Nom in l/s and m³/h : Nominal flow rate (100 %)<br />
V in l/s and m³/h : Volume flow rate<br />
∆V in ± % : Flow rate tolerance from setpoint value<br />
Vmin in l/s and m³/h : Set minimum volume flow rate<br />
V max in l/s and m³/h : Set maximum volume flow rate<br />
V min unit in l/s und m³/h : Minimum volume flow rate for unit<br />
∆pst<br />
in Pa : Static pressure differential<br />
∆pst min in Pa : Static minimum pressure differential<br />
All sound power levels are based on 1 pW, all sound pressure<br />
levels on 20µPa.<br />
All noise levels were determined in a reverberation chamber.<br />
The sound power data has been determined and corrected<br />
according to EN ISO 5135, February 1999.<br />
Technical data based on an air density of 1.2 kg/m³.<br />
10 20 30 40 50 60 70 80 90 100<br />
Vmin<br />
10 20 30 40 50 60 70 80 90 100<br />
Air flow velocity<br />
in m/s (approx.)<br />
0.6 1.2 1.8 2.4 3.0 3.6 4.2 4.8 5.2 6.0<br />
V max<br />
Nominal<br />
size<br />
125<br />
l/s 8 15 25 30 40 45 55 60 70 75<br />
m³/h 30 55 80 110 135 160 190 215 245 270<br />
160<br />
l/s 12 25 35 50 60 70 85 95 110 120<br />
m³/h 45 85 130 170 215 260 300 345 385 430<br />
200<br />
l/s 20 40 55 75 95 115 135 150 170 190<br />
m³/h 70 135 205 275 340 410 480 550 615 685<br />
250<br />
l/s 30 60 90 120 150 180 210 240 270 300<br />
m³/h 110 215 325 430 540 650 755 865 970 1080<br />
6