GAS INSTALLATION 5-3<br />
Heating and Hot Water Supply<br />
C<br />
A<br />
E<br />
D<br />
B<br />
Up<br />
Middle<br />
Down 1<br />
Down 2<br />
The Trumatic heating system in your<br />
<strong>Karmann</strong> <strong>Mobil</strong>e Home is equipped in<br />
addition with an integrated 12 ltr. Boiler to<br />
supply the bathroom and the kitchen with hot<br />
water. The combination unit is located under<br />
the wardrobe (550, 600, 650, 660, 655TI, 665TI,<br />
675TI) and under the bed (625TI). The control<br />
element is mounted above the body door. The<br />
warmed heating air is distributed throughout<br />
the living room by means of a circulation fan.<br />
In summer mode (water heating without room<br />
heating) the service water is heated up on<br />
the lowest burner stage. Once the water<br />
temperature set has been reached, the<br />
burner switches off. The yellow lamp (E) goes<br />
out.<br />
In winter mode the unit determines<br />
automatically through the thermostat which<br />
burner stage is needed.<br />
Once the desired temperature has been<br />
reached:<br />
- with the switch at Down 1, the heating<br />
switches off regardless of the water<br />
temperature, and with the boiler full the<br />
water is automatically also heated, or<br />
- with the switch at Down 2, the hot air fan of<br />
the heating switches off and the content of<br />
the boiler is heated up to 60°C at the lowest<br />
burner stage.<br />
Control element and modes of<br />
operation<br />
A = Knob for room temperature<br />
When the unit is switched on the green<br />
pilot light (B) of the knob must light up. If<br />
the light does not light up, check the fuse<br />
III on the control panel (p. 6-2).<br />
C = Knob with five positions<br />
- Up = Boiler (summer mode,<br />
temperature 60°C or 40°C)<br />
- Middle = Off<br />
- Down 1 = Heating + Boiler (winter mode,<br />
without hot water requirement)<br />
- Down 2 = Heating + Boiler (winter mode,<br />
with hot water requirements, 60°C)<br />
D = Red pilot light "Fault"<br />
Indicates a fault in the gas or power sup<br />
ply. In such a case consult the fault table<br />
(see p. 12-2) or the attached operating in<br />
structions of the combination unit.