FAULT IDENTIFICATION AND ELIMINATION 12-3<br />

Heating/hot water<br />

Fault<br />

"Operating" (green) lamp at the Trumatic<br />

device is not illuminated<br />

"Operating" (green) lamp at the Trumatic<br />

device is not illuminated<br />

Frost protection valve has opened and<br />

emptied the boiler<br />

Possible cause<br />

Fuse triggered<br />

Body battery too weak or faulty<br />

Body battery is too weak or faulty<br />

Temperature in boiler environment<br />

under 3°C<br />

Remedy<br />

Contact specialist repair shop<br />

Charge or change battery<br />

Close valve by hand and charge or change<br />

battery<br />

Warm up body (the valve can only be<br />

closed at 8°C)<br />

Frost protection valve cannot be closed<br />

Water drips from safety/ discharge valve<br />

Heating switches to fault mode after longer<br />

operating time<br />

Body battery is too weak or faulty<br />

Frost protection valve faulty<br />

Water pressure too high<br />

Hot air heat exchanger blocked<br />

Gas pressure regulator iced up<br />

Proportion of butane in gas cylinder too high<br />

Charge or replace battery<br />

Contact specialist repair shop<br />

Check pump pressure, max. 2.8 bar<br />

Check discharge opening<br />

Use De-icer<br />

Use propane