Information Handbook: <strong>Condensation</strong> <strong>in</strong> Build<strong>in</strong>gs<br />

Figure 4.16 – Indoor sources of water vapour <strong>in</strong> dwell<strong>in</strong>gs and rates of release<br />

(Source: BRANZ 2012)<br />

Cook<strong>in</strong>g: 5 kg per day – unvented, gas fired<br />

Launder<strong>in</strong>g: 0.6 kg per day – unvented<br />

2 hours of cook<strong>in</strong>g per day wash<strong>in</strong>g every 5 days, dry<strong>in</strong>g every 10 days<br />

1 kg per day<br />

Dishwash<strong>in</strong>g: 1 kg per day<br />

3 kg per day<br />

(if not vented outdoors)<br />

2 kg extra if gas fired<br />

0.2 kg per person per hour<br />

Wash<strong>in</strong>g<br />

0.5 kg per load<br />

1.5 kg per person<br />

(if not vented outdoors)<br />

Dry<strong>in</strong>g<br />

5 kg per load<br />

(if not vented outdoors)<br />

Bath<strong>in</strong>g/Shower<strong>in</strong>g: 6 kg per day for 4 people – unvented<br />

0.5-1 kg per hour<br />

(if unflued)<br />

DRAFT HANDBOOK<br />

Occupants:5.5 kg per day for family of four<br />

absent / active / asleep 8 hours each<br />

Gas heat<strong>in</strong>g: 4 kg per day – if unflued<br />

(dog not <strong>in</strong>cluded)<br />

<strong>Australian</strong> Build<strong>in</strong>g <strong>Codes</strong> <strong>Board</strong> Page 46