STOVE GUIDE - DanSkan
STOVE GUIDE - DanSkan
STOVE GUIDE - DanSkan
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
MODERN LINE<br />
<strong>STOVE</strong>S<br />
CONCEPT M 1:10<br />
PLANNING INFORMATION<br />
Planning Information<br />
D and M = Three Quarter<br />
Round Stoves<br />
N = Full Round Stoves<br />
Minimum distnce to wall:<br />
- 7 cm to non-combustible<br />
materials<br />
- 20 cm to combustible<br />
materials<br />
>7 or 20 cm<br />
Base Plate for D, M and N<br />
Series Stoves<br />
Minimum distance to<br />
combustible materials<br />
from side panels<br />
> 20 cm<br />
*<br />
D+M=<br />
N=<br />
Minimum distance to<br />
combustible materials<br />
from double side windows<br />
> 55 cm<br />
D+M=<br />
N=<br />
D+M= / N=<br />
D+M= / N=<br />
*External air inlet centre<br />
Flue pipe diameter: 15cm (6“)<br />
External air duct diameter: 10cm (4“)<br />
FH = External air:<br />
height between floor and fire chamber base<br />
DANNE = 13 cm<br />
DANA / DANO / MODA /<br />
MODO = 26 cm<br />
DANOS / MODUS = 43 cm<br />
NURO 100 = 21,5 cm<br />
NURO 120/160 = 38 cm<br />
HB<br />
FB = External air:<br />
height to centre of connection apertre on rear<br />
HT<br />
HT = Height for top flue connection<br />
DANNE = 85 cm<br />
DANA / MODA = 98 cm<br />
DANO / DANOS / MODO /<br />
MODUS = 115 cm<br />
NURO 100 = 93,5 cm<br />
NURO 120/160 = 110,5 cm<br />
DANNE = 5,5 cm<br />
DANA / DANO / DANOS<br />
MODA / MODO / MODUS /<br />
NURO 100= 13,5 cm/<br />
NURO 120/160 = 17,5 cm<br />
FH<br />
FB<br />
M 1:20<br />
HB = height to centre of rear flue<br />
DANO / MODO = 108 cm<br />
NURO 160 = 127 cm<br />
D+M<br />
N<br />
Under-floor external air connection in centre of base<br />
81