06.10.2014 Views

STOVE GUIDE - DanSkan

STOVE GUIDE - DanSkan

STOVE GUIDE - DanSkan

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Österreich<br />

15a B-VG<br />

FRANCE / B / NL<br />

VHR-Houtkeur<br />

TNO<br />

Vereinigung<br />

Kantonaler<br />

Feuerversicherungen<br />

CERTIFY<br />

TEST–<br />

CENTRE<br />

P/F = Pollution / Fine particulates at 13% O ²<br />

/ Nm 3<br />

CO % = Hydrocarbon % at 13% O ²<br />

/ Nm 3<br />

CO g = Hydrocarbon g at 13% O ²<br />

/ Nm 3<br />

EFF = Efficiency (%)<br />

KL = Temperature in storage compartment (ºC)<br />

AIRBOX = AIRBOX-A / AIRBOX B/DIBt<br />

Model<br />

P/F<br />

mg<br />

HEIGHTS, EXTERNAL AIR ETC…<br />

CO<br />

%<br />

CO<br />

g<br />

EFF.<br />

%<br />

89<br />

KL<br />

C°<br />

AIR-<br />

BOX<br />

ALPHA < 29 < 0,09 0,50 > 80 < 50 A+B<br />

HARMONY < 29 < 0,09 0,50 > 80 < 50 A+B<br />

CRISTAL < 29 < 0,09 0,50 > 80 < 50 A+B<br />

SOLO < 29 < 0,09 0,37 > 80 < 50 A+B<br />

NOVO < 29 < 0,09 0,37 > 80 < 50 A+B<br />

PRISMA < 29 < 0,09 1,20 > 80 < 50 A+B<br />

OPRA < 29 < 0,09 1,20 > 80 < 50<br />

TOPO < 29 < 0,09 1,12 > 80 < 50 A+B<br />

SWING < 29 < 0,09 1,12 > 80 < 50 A+B<br />

TWIST < 29 < 0,09 1,12 > 80 < 50 A+B<br />

KARAT < 29 < 0,09 0,62 > 80 < 50 A+B<br />

CLN < 29 < 0,09 0,75 > 80 < 50 A+B<br />

DOM N < 29 < 0,09 0,75 > 80 < 50 A+B<br />

RONDO H < 29 < 0,09 0,87 > 80 < 50 A+B<br />

RONDO R < 29 < 0,09 0,87 > 80 < 50 B<br />

RONDO NH < 29 < 0,09 0,87 > 80 < 50 A+B<br />

RONDO NR < 29 < 0,09 0,87 > 80 < 50 B<br />

DOM CL < 29 < 0,09 0,75 > 80 < 50<br />

DANNE < 20 0,07 0,87 82,1 < 50 DIBt<br />

DANA < 20 0,07 0,87 82,1 < 50 DIBt<br />

DANOS < 20 0,07 0,87 82,1 < 50 DIBt<br />

DANO < 23 0,10 1,25 80,5 < 50 DIBt<br />

MODA < 23 0,10 1,20 84,0 < 50 DIBt<br />

MODUS < 23 0,10 1,20 84,0 < 50 DIBt<br />

MODO < 23 0,07 0,87 84,8 < 50 DIBt<br />

NURO 100 D < 26 0,07 0,87 80 < 50 DIBt<br />

NURO 120 D < 26 0,07 0,87 80 < 50 DIBt<br />

NURO 160 D < 24 0,06 0,75 81,8 < 50 DIBt<br />

NURO 100 M < 23 0,09 1,12 81,3 < 50 DIBt<br />

NURO 120 M < 23 0,09 1,12 81,3 < 50 DIBt<br />

NURO 160 M < 24 0,06 0,75 81,8 < 50 DIBt<br />

ENVIRONMENTAL<br />

PROTECTION<br />

WITH DAN SKAN AUTOMATIC<br />

= Intelligent combustion<br />

All DAN SKAN stoves are tested in approved<br />

independent testing laboratories where<br />

they are scrutinised for function and safety.<br />

All test results are significantly better than<br />

the requirements of international limits and<br />

standards. For example, regarding fine particles<br />

pollution (P/F), our results are more<br />

than 25% less than the minimum values<br />

required in the strict German BImschV,<br />

Stage II tests. The achievable efficiency of<br />

all DAN SKAN stoves – when used correctly<br />

– is between 80 and 90%.<br />

TYPES OF TEST<br />

Tests passed include the European standard<br />

CE test DIN EN 13240 certification<br />

programme, DIN Plus and the strict air<br />

pollution criteria for German cities including<br />

Munich and historic Regensburg as<br />

well as the previously mentioned German<br />

BImschV, Stage II. Others include tests for<br />

Austrian and Swiss standards.<br />

EXTERNAL COMBUSTION AIR<br />

DAN SKAN stove are ready to be used with<br />

100% external combustion air supply, if<br />

needed. The original EX-AIR-1 system, with<br />

connection from the external air and the air<br />

in the room, enables pressure equalisation<br />

in the room where the stove is installed. The<br />

EX-AIR-2 system enables pre-heated combustion<br />

air through the DAN SKAN patented<br />

AIRBOX (see pages 72 and 73).<br />

CHIMNEY STACK REQUIREMENTS<br />

Chimney systems with an inner diameter<br />

of 180 mm or more and less than 5 metres<br />

effective height could cause problems with<br />

the safe and efficient operation of your<br />

stove. Larger diameters cool the flue gases<br />

and provide insufficient draught and could<br />

cause smoke to enter the room. Smaller<br />

diameters and stack heights of 6 metres<br />

and over are strongly recommended (see<br />

page 85).

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!