Residential Concealed Pendent Sprinklers - Tyco Fire Products

Residential Concealed Pendent Sprinklers - Tyco Fire Products

Residential Concealed Pendent Sprinklers - Tyco Fire Products

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

The <strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> (TFP) <strong>Residential</strong> <strong>Fire</strong><br />

Protection Package offers a diverse line of products<br />

that are aesthetically pleasing, as well as functional.<br />

Our residential sprinklers are among the most water<br />

and pressure efficient in the fire protection industry.<br />

They are available in recessed pendent, sidewall<br />

and recessed sidewall types, as well as low profile<br />

concealed and flush styles. Adequate water supply to<br />

fire sprinklers is critical for proper fire protection.<br />

The residential domestic shutoff valve, which<br />

automatically shuts off essentially all of the water<br />

flow to the domestic system when a sprinkler operates,<br />

assures that nearly the entire water supply is diverted<br />

to the fire sprinkler system. BlazeMaster CPVC pipe<br />

and fittings, along with the necessary hangers and<br />

pipe joint adhesives help make the TFP <strong>Residential</strong><br />

<strong>Fire</strong> Protection Package the best and most complete<br />

in the industry.<br />

Customer Service<br />

TFP residential package consists of<br />

products manufactured by TFP and<br />

distributed through local TFP locations<br />

or independent distributors that are<br />

strategically located to provide our<br />

customers with the quickest delivery<br />

possible of their complete order.<br />

2<br />

Research & Development<br />

TFP has the largest research and<br />

development staff in the fire<br />

protection industry. We combine<br />

new technologies with proven fire<br />

protection science to provide the<br />

products necessary to meet the<br />

present and future building needs.


Table of Contents<br />

Series LFII <strong>Residential</strong> <strong>Sprinklers</strong><br />

Series LFII <strong>Pendent</strong> . . . . . . . . . . . . . . . . . .4<br />

Series LFII Horizontal Sidewall . . . . . . . .5<br />

Series LFII <strong>Concealed</strong> <strong>Pendent</strong> . . . . . . . . .6<br />

Series LFII Domed <strong>Concealed</strong> <strong>Pendent</strong> . . .6<br />

Series LFII Flush <strong>Pendent</strong> . . . . . . . . . . . . .7<br />

CPVC Pipe & Piping Systems<br />

CPVC Pipe & Fittings . . . . . . . . . . . . . . .8<br />

CPVC Piping Systems . . . . . . . . . . . . . . .9<br />

Sprinkler System Components<br />

Valves, Resi-Riser & Riser Manifold . . . .10<br />

Waterflow Detector & Alarm Bell . . . . .11<br />

Hangers & Installation Equipment . . . . .11<br />

Installation Guidelines . . . . . . . . . . . . . .12<br />

3


Series LFII (TY2234) <strong>Residential</strong> <strong>Pendent</strong> <strong>Sprinklers</strong> &<br />

Series LFII (TY1334) <strong>Residential</strong> Horizontal Sidewall <strong>Sprinklers</strong> are decorative, fast<br />

response sprinklers designed for use in residential occupancies such as homes,<br />

apartments, dormitories and hotels.<br />

When aesthetics and optimized flow characteristics are the major consideration,<br />

Series LFII <strong>Residential</strong> <strong>Pendent</strong> & Horizontal <strong>Sprinklers</strong> should be the first choice.<br />

The <strong>Residential</strong> <strong>Pendent</strong> and Recessed <strong>Pendent</strong> <strong>Sprinklers</strong> are listed for special<br />

applications with beamed ceilings. The full line of LFII <strong>Sprinklers</strong> can be used for<br />

horizontal and SLOPED ceilings.<br />

Series LFII are to be used in:<br />

•Wet pipe residential sprinkler systems for one/two–<br />

family dwellings and mobile homes per NFPA 13D<br />

•Wet pipe residential occupancies up to and including<br />

four stories in height per NFPA 13R<br />

•Wet pipe sprinklers systems for the residential<br />

portions of any occupancy per NFPA 13<br />

4<br />

Series LFII (TY2234)<br />

<strong>Residential</strong> <strong>Pendent</strong> &<br />

Recessed <strong>Pendent</strong> <strong>Sprinklers</strong><br />

Finishes: White, Chrome or Natural Brass<br />

MAXIMUM MINIMUM FLOW (b) & MINIMUM FLOW (b) & MINIMUM FLOW (b) &<br />

COVERAGE AREA (a) RESIDUAL PRESSURE RESIDUAL PRESSURE RESIDUAL PRESSURE<br />

For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling<br />

ft x ft (m x m) (Max. 2" rise for 12" run) (Greater than 2" rise up to<br />

max. 4" rise for 12" run)<br />

(Greater than 4" rise up to<br />

max. 8" rise for 12" run)<br />

155°F/68°C or 175°F/79°C 155°F/88°C 175°F/79°C 155°F/88°C 175°F/79°C<br />

12 X12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)<br />

(3,7 X 3,7) 7.0 psi (0.48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0.48 bar) 13.5 psi (0.93 bar)<br />

14 X 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)<br />

(4,3 X 4,3) 7.0 psi (0.48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0.48 bar) 13.5 psi (0.93 bar)<br />

16 X 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 13 GPM (49,2 LPM) 18 GPM (68,1 LPM)<br />

(4,9 X 4,9) 7.0 psi (0.48 bar) 7.0 psi (0,48 bar) 12.0 psi (0,83 bar) 7.0 psi (0.48 bar) 13.5 psi (0.93 bar)<br />

18 X 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 17 GPM (64,3 LPM) 23 GPM (87,1 LPM)<br />

(5,5 X 5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar) 22.0 psi (1,52 bar)<br />

20 X 20 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) 21 GPM (79,5 LPM) N/A<br />

(6,1 X 6,1) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar) N/A<br />

See Technical Data Sheet: TFP400 prior to design & installation for all criteria<br />

(a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic<br />

design criteria are stated.<br />

(b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic<br />

Design Criteria Section for details.


Series LFII (TY1334)<br />

<strong>Residential</strong> Horizontal Sidewall &<br />

Recessed Horizontal Sidewall <strong>Sprinklers</strong><br />

Finishes: White, Chrome, or Natural Brass<br />

MAXIMUM<br />

COVERAGE<br />

MINIMUM FLOW & PRESSURE<br />

ft x ft (m x m) 4" – 6" (100mm – 150mm) below ceiling 6" – 12" (150mm – 300mm) below ceiling<br />

155°F/68°C 175°F/79°C 155°F/68°C 175°F/79°C<br />

12 x 12 12 GPM (45,4 LPM) 12 GPM (45,4 LPM) 13 GPM (49,2 LPM) 13 GPM (49,2 LPM)<br />

(3,7 x 3,7) 8.2 psi (0,57 bar) 8.2 psi (0,57 bar) 9.6 psi (0,66 bar) 9.6 psi (0,66 bar)<br />

14 x 14 14 GPM (53,0 LPM) 16 GPM (60,6 LPM) 17 GPM (64, 3 LPM) 18 GPM (68, 1 LPM)<br />

(4,3 X 4,3) 11.1 psi (0,77 bar) 14.5 psi (1.00 bar) 16.4 psi (1,13 bar) 18.4 psi (1,27 bar)<br />

16 x 16 16 GPM (60,6 LPM) 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM)<br />

(4,9 X 4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar)<br />

16 x 18 19 GPM (71,9 LPM) 19 GPM (71,9 LPM) 21 GPM (79,5 LPM) 21 GPM (79,5 LPM)<br />

(4,9 x 5,5) 20.5 psi (1,41 bar) 20.5 psi (1,41 bar) 25.0 psi (1,72 bar) 25.0 psi (1,72 bar)<br />

16 x 20 23 GPM (87,1 LPM) 23 GPM (87,1 LPM) 26 GPM (98,4 LPM) 26 GPM (98,4 LPM)<br />

(4,9 x 6,1) 30.0 psi (2,07 bar) 30.0 psi (2,07 bar) 38.3 psi (2,64 bar) 38.3 psi (2,64 bar)<br />

See Technical Data Sheet: TFP410 prior to design & installation for all criteria<br />

C<br />

Series LFII (TY1334)<br />

<strong>Residential</strong> Horizontal Sidewall &<br />

Recessed Horizontal Sidewall <strong>Sprinklers</strong><br />

<strong>Sprinklers</strong> located along the slope and positioned to discharge across the slope.<br />

E<br />

A<br />

B<br />

E<br />

A<br />

D<br />

MAXIMUM<br />

MINIMUM FLOW & PRESSURE<br />

COVERAGE For Sloped Ceilings For Sloped Ceilings*<br />

ft x ft (m x m) max. 4" rise for 12" run max. 8" rise for 12" run<br />

155°F/68°C • 175°F/79°C<br />

155°F/68°C • 175°F/79°C<br />

12 x 12 16 GPM (60,6 LPM) 16 GPM (60,6 LPM)<br />

(3,7 x 3,7) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar)<br />

14 x 14 16 GPM (60,6 LPM) 16 GPM (60,6 LPM)<br />

(4,3 x 4,3) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar)<br />

16 x 16 16 GPM (60,6 LPM) 16 GPM (60,6 LPM)<br />

(4,9 x 4,9) 14.5 psi (1,00 bar) 14.5 psi (1,00 bar)<br />

16 x 18 22 GPM (83,3 LPM) —<br />

(4,9 x 5,5) 27.4 psi (1,89 bar) —<br />

See Technical Data Sheet: TFP410 prior to design & installation for all criteria<br />

* Three sprinkler design when there are more than two sprinklers in a compartment.<br />

5


The Series LFII (TY2596) <strong>Residential</strong> <strong>Concealed</strong> <strong>Pendent</strong> <strong>Sprinklers</strong> are decorative, fast response, sprinklers<br />

designed for use in residential occupancies such as homes, apartments, dormitories, and hotels.<br />

•Can be used for horizontal and sloped ceilings<br />

•Wet pipe residential sprinkler systems for oneand<br />

two-family dwellings and mobile homes per<br />

NFPA 13D<br />

•Wet pipe residential sprinkler systems for residential<br />

occupancies up to and including four stories in height<br />

per NFPA 13R<br />

•Wet pipe sprinkler systems for the residential portions<br />

of any occupancy per NFPA 13<br />

Series LFII (TY2234)<br />

<strong>Residential</strong> Domed <strong>Concealed</strong> <strong>Pendent</strong> <strong>Sprinklers</strong><br />

Cover Plate Finishes: White Painted* or Chrome Plated<br />

*Custom colors upon request. See Technical Data Sheet: TFP450 prior to design & installation<br />

(a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated.<br />

(b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.<br />

Series LFII (TY2596)<br />

<strong>Residential</strong> <strong>Concealed</strong> <strong>Pendent</strong> <strong>Sprinklers</strong><br />

Cover Plate Finishes: White Painted* or Chrome Plated<br />

MAXIMUM MINIMUM FLOW (b) & MINIMUM FLOW (b) & MINIMUM FLOW (b) &<br />

COVERAGE AREA (a) RESIDUAL PRESSURE RESIDUAL PRESSURE RESIDUAL PRESSURE<br />

For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling<br />

ft x ft (m x m) (Max. 2" rise for 12" run) (Greater than 2" rise up to<br />

max. 4" rise for 12" run)<br />

(Greater than 4" rise up to<br />

max. 8" rise for 12" run)<br />

160°F/71°C 160°F/71°C 160°F/71°C<br />

12 x 12 13 GPM (49,2 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM)<br />

(3,7 x 3,7) 9.6 psi (0,66 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar)<br />

14 x 14 14 GPM (53,0 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM)<br />

(4,3 x 4,3) 11.1 psi (0,77 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar)<br />

16 x 16 16 GPM (60,6 LPM) 18 GPM (68,1 LPM) 18 GPM (68,1 LPM)<br />

(4,9 x 4,9) 14.5 psi (1,00 bar) 18.4 psi (1,27 bar) 18.4 psi (1,27 bar)<br />

18 x 18 20 GPM (75,7 LPM) 20 GPM (75,7 LPM) N/A<br />

(5,5 x 5,5) 22.7 psi (1,57 bar) 22.7 psi (1,57 bar) N/A<br />

20 x 20 24 GPM (90,8 LPM) 26 GPM (98,4 LPM) N/A<br />

(6,1 x 6,1) 32.7 psi (2,25 bar) 38.3 psi (2,64 bar) N/A<br />

*Custom colors upon request. See Technical Data Sheet: TFP440 prior to design & installation<br />

(a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic design criteria are stated.<br />

(b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic Design Criteria Section for details.<br />

6<br />

MAXIMUM MINIMUM FLOW (b) & MINIMUM FLOW (b) &<br />

COVERAGE AREA (a) RESIDUAL PRESSURE RESIDUAL PRESSURE<br />

For Horizontal Ceiling<br />

For Sloped Ceiling<br />

(Greater than 2" rise up to<br />

ft x ft (m x m) (Max. 2" rise for 12" run) max. 4" rise for 12" run)<br />

155°F/68°C<br />

155°F/88°C<br />

12 X12 13 GPM (49,2 LPM) 13 GPM (49,2 LPM)<br />

(3,7 X 3,7) 7.0 psi (0.48 bar) 7.0 psi (0.48 bar)<br />

14 X 14 13 GPM (49,2 LPM) 13 GPM (49,2 LPM)<br />

(4,3 X 4,3) 7.0 psi (0.48 bar) 7.0 psi (0.48 bar)<br />

16 X 16 13 GPM (49,2 LPM) 13 GPM (49,2 LPM)<br />

(4,9 X 4,9) 7.0 psi (0.48 bar) 7.0 psi (0.48 bar)<br />

18 X 18 17 GPM (64,3 LPM) 17 GPM (64,3 LPM)<br />

(5,5 X 5,5) 12.0 psi (0,83 bar) 12.0 psi (0,83 bar)<br />

20 X 20 20 GPM (75,7 LPM) 21 GPM (79,5 LPM)<br />

(6,1 X 6,1) 16.7 psi (1,15 bar) 18.4 psi (1,27 bar)


Series LFII (TY2284) <strong>Residential</strong> Flush <strong>Pendent</strong> <strong>Sprinklers</strong> are decorative, fast<br />

response, fusible solder sprinklers designed for use in residential occupancies<br />

such as homes, apartments, dormitories, and hotels and can be installed in<br />

beamed*, sloped and horizontal ceilings. When aesthetics is the major<br />

consideration, the Series LFII (TY2284) should be the first choice.<br />

•<strong>Residential</strong> Flush <strong>Pendent</strong> and <strong>Sprinklers</strong> approved for special<br />

applications with beamed ceilings<br />

•Used in wet pipe residential sprinkler systems for one- and twofamily<br />

dwellings and mobile homes per NFPA 13D<br />

•Wet pipe residential sprinkler systems for residential occupancies<br />

up to and including four stories in height per NFPA 13R<br />

•Wet pipe sprinkler systems for the residential portions of any<br />

occupancy per NFPA 13<br />

* <strong>Pendent</strong>, recessed pendent, and flush pendent sprinklers are approved for use with beamed ceilings.<br />

Series LFII (TY2284)<br />

<strong>Residential</strong> Flush<br />

<strong>Pendent</strong> <strong>Sprinklers</strong><br />

Sprinkler & Escutcheon Finishes: White and Chrome<br />

MAXIMUM MINIMUM FLOW (b) & MINIMUM FLOW (b) & MINIMUM FLOW (b) &<br />

COVERAGE RESIDUAL PRESSURE RESIDUAL PRESSURE RESIDUAL PRESSURE<br />

AREA (a) For Horizontal Ceiling For Sloped Ceiling For Sloped Ceiling*<br />

ft x ft (m x m) (Max. 2" rise for 12" run) (Max. 8" rise for 12" run) (Max. 8" rise for 12" run)<br />

162°F/72°C 162°F/72°C 162°F/72°C<br />

12 x 12 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 14 GPM (53,0 LPM)<br />

(3,7 x 3,7) 9.6 psi (0,66 bar) 16.4 psi (1,13 bar) 11.1 psi (0,77 bar)<br />

14 x 14 13 GPM (49,2 LPM) 17 GPM (64,3 LPM) 14 GPM (53,0 LPM)<br />

(4,3 x 4,3) 9.6 psi (0,66 bar) 16.4 psi (1,13 bar) 11.1 psi (0,77 bar)<br />

16 x 16 14 GPM (53,0 LPM) 17 GPM (64,3 LPM) 14 GPM (53,0 LPM)<br />

(4,9 x 4,9) 11.1 psi (0,77 bar) 16.4 psi (1,13 bar) 11.1 psi (0,77 bar)<br />

18 x 18 18 GPM (68,1 LPM) 19 GPM (71,9 LPM) 18 GPM (68,1 LPM)<br />

(5,5 x 5,5) 18.4 psi (1,27 bar) 20.5 psi (1,41 bar) 18.4 psi (1,27 bar)<br />

20 x 20 22 GPM (83,3 LPM) 24 GPM (90,8 LPM) N/A<br />

(6,1 x 6,1) 27.4 psi (1,89 bar) 32.7 psi (2,25 bar) N/A<br />

See Technical Data Sheet: TFP420 prior to design & installation<br />

* Three sprinkler design when there are more than two sprinklers in a compartment.<br />

(a) For coverage area dimensions less than or between those indicated, it is necessary to use the minimum required flow for the next highest coverage area for which hydraulic<br />

design criteria are stated.<br />

(b) Requirement is based on minimum flow in GPM (LPM) from each sprinkler. The associated residual pressures are calculated using the nominal K-factor. Refer to Hydraulic<br />

Design Criteria Section for details.<br />

7


<strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> CPVC Pipe & Fittings manufactured with<br />

Noveon's BlazeMaster ® compound are Listed by Underwriters<br />

Laboratories, Inc. for use in:<br />

•Light Hazard occupancies as defined in the Standard for<br />

Installation of <strong>Fire</strong> Sprinkler Systems, NFPA 13.<br />

•<strong>Residential</strong> occupancies as defined in the Standard for<br />

Installation of <strong>Fire</strong> Sprinkler Systems in <strong>Residential</strong><br />

Occupancies up to Four Stories in Height, NFPA 13R.<br />

•<strong>Residential</strong> occupancies as defined in the Standard for<br />

<strong>Fire</strong> Sprinkler Systems In One and Two Family<br />

Dwellings and Manufactured Homes, NFPA 13D.<br />

•Air plenums, as defined by the installation of Air<br />

Conditioning and Ventilating Systems, NFPA 90A<br />

and model mechanical codes.<br />

•Underground Water Pressure Service, NFPA 24.<br />

•Unfinished Basements.<br />

CPVC to Copper Fitting<br />

<strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> make transition<br />

from one piping material to another<br />

simple. The transition to steel or<br />

BlazeMaster ® CPVC <strong>Fire</strong> Sprinkler<br />

System piping from traditional copper<br />

tube for plumbing services is fast,<br />

easy, and readily available in the most<br />

complete <strong>Fire</strong> Sprinkler package in<br />

the industry.<br />

TFP BlazeMaster ® CPVC can be used with the entire<br />

LFII line in residential occupancies.<br />

8<br />

(Note: for complete Listing and Approval information, please<br />

refer to the Installation Instructions and Technical Manual No.<br />

19-1.0 or call Technical Services at 800-381-9312)<br />

The “Back-to-Back”<br />

Fitting is included in the<br />

TFP line of BlazeMaster ®<br />

CPVC products.This TEE<br />

allows two sidewall sprinklers<br />

to be piped into one fitting.<br />

This is ideal when the CPVC<br />

piping is located in a 3-1/2" (2x4)<br />

vertical wall, eliminating the need for<br />

extra nipples, fittings and sprinkler<br />

head adapters typically associated<br />

with supplying two rooms with the<br />

same pipe.The “Back-to-Back” TEE<br />

has been specially designed and<br />

dimensioned to enable the sidewall<br />

sprinklers to be recessed with 1/2" or<br />

5/8" sheet-rock wall covering.


The <strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> CPVC Piping Systems, an<br />

extremely fast method of installing fire protection<br />

piping, is UL and cUL Listed and FM approved. The<br />

CPVC products exceed ASTM standards, and includes<br />

our 10 Year Warranty from an ISO 9001-2000 Certified<br />

Company. Benefits over traditional piping systems include:<br />

• Easily field fabricates with low tooling investment<br />

•Resistant to rust, scale and foreign<br />

contaminant build-up<br />

•Superior flow characteristics for increased<br />

hydraulic capabilities (C-Factor=150)<br />

• Easily transported, handled<br />

and modified on site<br />

•Can be easily connected to<br />

copper and steel piping<br />

•Resists sweating and condensation<br />

•Immune to microbiologically<br />

influenced corrosion (MIC)<br />

TFP's Revolutionary<br />

“No Block” Hanger is a<br />

simple two-hole strap that eliminates<br />

“blocking” to the beam when hanging<br />

CPVC.The “No Block” Hanger<br />

positions the face of the CPVC pipe<br />

1-1/2" off the face of the joist or stud.<br />

<strong>Fire</strong> Performance<br />

• CPVC has an LOI (Limited Oxygen Index) that is<br />

better than wood, PVC, PB or other common<br />

building materials. It will not support combustion;<br />

therefore, it cannot be the source of a fire or cause a<br />

fire to spread.<br />

•Does not contribute to flashover<br />

•Low smoke generation<br />

•Toxicity is extremely low when compared with<br />

common building and finishing materials.<br />

Equal to wood and less than wool or cotton<br />

(University of Pittsburgh protocol).<br />

9


<strong>Residential</strong> Domestic Shutoff Valve<br />

• 1" and 2" (25.4 and 50.8 mm) are used in piping systems that<br />

supply water to both the domestic service and the fire sprinkler<br />

system designed per NFPA 13D in one and two-family dwellings<br />

and mobile homes<br />

•In the set position, water is available on demand to the<br />

domestic system and the valve acts as a check valve for the fire<br />

protection system<br />

• When a sprinkler operates, the supply to the domestic system is<br />

automatically shut off<br />

• Maximum use of available water supply on demand for fire protection<br />

•Eliminates the need for expensive pumps, pressurized<br />

tanks, or electrically operated domestic shutoff valves<br />

Model F540, <strong>Residential</strong> Domestic Shutoff Valve<br />

“Butterball” Butterfly Valves<br />

“Butterball” Butterfly valves are ideal for use in small fire sprinkler<br />

systems as sectional or main control valves.As an alternative to bulky<br />

OS&Y valves, they provide the mandated visual indicator showing that the<br />

valve is open or closed.They are available in sizes from 1" through 2-1/2".<br />

Resi-Riser<br />

• Compact, pre-assembled, ready to install sprinkler riser<br />

• Brass construction for use in potable water supply<br />

•Available in 1"-2" (25-50 mm) sizes<br />

• Integral test and drain assembly, flow switch with retard mechanism,<br />

300 psi gauge, and check valve<br />

• Compact size allows for easy installation between<br />

2" x 4" studs in wall<br />

• Molded mounting points allow for fast and easy left or<br />

right hand installation<br />

•Available with or without pressure relief valve<br />

feature and flow switch retard mechanism<br />

10<br />

Riser Manifold<br />

The Riser Manifold provides all of the accessory equipment for a<br />

system riser in a single assembly.The availability of the Riser Manifold<br />

in different configurations allows cost-effective riser installation in<br />

commercial (NFPA 13) systems, high rises requiring floor control<br />

assemblies, and residential systems (NFPA 13R/13D).


Model VS-SP Waterflow Detector<br />

• Used with wet pipe fire sprinkler systems in residential dwellings<br />

and mobile homes<br />

• Actuation of the switch can initiate an alarm indicating that the sprinkler<br />

system is operating<br />

•Sustained flow of 8 gallons per minute will deflect the vane and actuate a<br />

single-pole, double-throw snap action switch<br />

• Can be wired to a local bell and/or protection panel for outside notification<br />

an alarm company for fire department<br />

Model VS-SP, <strong>Residential</strong> Waterflow Detector<br />

Alarm Bell<br />

• The <strong>Tyco</strong> <strong>Fire</strong> Electric Alarm Bell is ideally suited for residential applications<br />

• This alarm is meant to be unobtrusive to the homeowner, yet<br />

absolutely dependable in a fire event<br />

• When used with a flow switch, if water flow occurs<br />

in a sprinkler system protecting residential<br />

occupancies, an audible alarm occurs to alert the<br />

occupants and neighbors of trouble<br />

Sprinkler Head Cabinet<br />

Spare sprinkler head cabinets are available as well as<br />

<strong>Residential</strong> 3 capacity sprinkler cabinet.All cabinets<br />

have ample room for sprinkler wrench storage.<br />

Hangers for BlazeMaster ® CPVC <strong>Products</strong><br />

TFP offers a full-line of pipe hangers designed especially for use with CPVC<br />

<strong>Products</strong>.They meet the requirements of NFPA 13 and have been<br />

manufactured to meet the quality standards that the industry demands.<br />

• Models 22, 23, and 24 pipe hangers are designed for ease of installation<br />

• Hangers have rounded edges to prevent damage to pipe and fittings<br />

• Meets requirements specified in NFPA 13, 13R, and 13D<br />

CPVC Installation Equipment<br />

•Retrofit Tools<br />

• Cutting and Deburring Tools<br />

• BlazeMaster ® Caulk & Walk ® <strong>Fire</strong>stop<br />

•One-Step CPVC Cement and Daubers<br />

•Hangers & Fasteners<br />

11


WORLDWIDE HEADQUARTERS<br />

<strong>Tyco</strong> <strong>Fire</strong> & Building <strong>Products</strong><br />

451 N. Cannon Avenue<br />

Lansdale, PA 19446<br />

215-362-0700, 800-523-6512<br />

Fax 215-362-5385<br />

www.<strong>Tyco</strong>-<strong>Fire</strong>.com<br />

UNITED STATES<br />

Central Sprinkler Company<br />

451 N. Cannon Avenue<br />

Lansdale, PA 19446<br />

215-362-0700, Fax 215-362-5385<br />

Brea, CA: Tel: 714-993-6111, Fax 714-993-6043<br />

Decatur, GA: Tel: 404-243-7336, Fax 404-244-7375<br />

King of Prussia, PA: Tel: 610-239-9925, Fax 610-239-9936<br />

Jessup, MD: Tel: 301-604-7133, Fax 301-604-7138<br />

Carol Stream, IL: Tel: 630-871-7700, Fax 630-871-7464<br />

Coppell, TX: Tel: 972-745-0043, Fax 972-745-8594<br />

Kent, WA: Tel: 253-872-6030, Fax 253-872-6547<br />

Avon, MA: Tel: 508-583-8447, Fax 508-583-0034<br />

Pompano Beach, FL: Tel: 954-781-0866, Fax 954-781-1475<br />

Murray, UT: Tel: 801-269-0688, Fax 801-269-0733<br />

Tigard, OR: Tel: 503-620-4203, Fax 503-620-3817<br />

Parma, OH: Tel: 216-265-0505, Fax 216-265-8354<br />

Kansas City, MO: Tel: 816-842-2424, Fax 816-842-4433<br />

National Distribution Facility<br />

PO Box 2806<br />

Lubbock, TX 79408-2806<br />

Gem Sprinkler Company & Star Sprinkler Inc.<br />

7071 S. 13th Street, Ste. 103<br />

Oak Creek, WI 53154<br />

877-436-8926, Fax 877-866-9250<br />

CANADA<br />

Regional Headquarters<br />

12-16715 Yonge Street, Suite 316<br />

Newmarket, Ontario L3X 1X4<br />

705-422-0010, Fax: 705-422-1396<br />

LATIN AMERICA<br />

Regional Headquarters<br />

South America, Central America & Caribbean<br />

1802 S.W. 2nd St.<br />

Pompano Beach, FL 33069<br />

954-781-0866, Fax 954-781-9330<br />

Regional Headquarters - Mexico<br />

Hamburgo 231A Piso 2<br />

Colonia Juarez<br />

Mexico, D.F. 06600 Mexico<br />

525-55-2075766, Fax: 525-55-2077566<br />

EUROPE & MIDDLE EAST<br />

Regional Headquarters<br />

Kopersteden 1, NL-7547 TJ Enschede<br />

P.O. Box 198, 7500 AD<br />

Enschede, The Netherlands<br />

31-53-428-4444, Fax 31-53-428-3377<br />

Stockport, UK: Tel: 44-161-477-1886, Fax 44-161-477-6729<br />

Paris Nord II, France: Tel: 33-1-48-178-727, Fax 33-1-48-178-720<br />

Rodgau Germany: Tel: 49-6106-84455, Fax 49-6106-18177<br />

Coslada Madrid, Spain: Tel: 34-1-669-3906, Fax 34-1-669-2018<br />

Lørenskog, Norway: Tel: 47-67-91-77-00, Fax 47-67-91-77-15<br />

Lammhult, Sweden: Tel: 46-472-269-980, Fax 46-472-269-989<br />

Dublin, Ireland: Tel: 353-166-839-82, Fax 353-166-822-54<br />

Bolzano, Italy: Tel: 39-0471-252-091, Fax 39-0471-254-058<br />

Milano, Italy: Tel: 39-0293-548-736, Fax 39-0293-548-690<br />

Dubai, United Arab Emirates: Tel: 971-488-38689, Fax 971-488-38674<br />

Budapest, Hungary: Tel: 36-148-11-383, Fax 36-120-34-427<br />

Wels/Thalheim, Austria: Tel: 43-072-42-65-054, Fax 43-072-42-74-393<br />

ASIA<br />

Regional Headquarters<br />

No.45 Tuas Avenue 9,<br />

Singapore 639189<br />

Central Sprinkler Company<br />

Singapore: 65- 6743-3212, Fax 65-6743-9181<br />

Shanghai, China: 86-21-5868-3300, Fax 86-21-5868-1160<br />

Beijing, China: 86-10-6515-6191, Fax 86-10-6515-6157<br />

Chengdu, China: 86-28-689-9440, Fax 86-28-666-2538<br />

Gem Sprinkler Company & Star Sprinkler Inc.<br />

Singapore: 65-6861-1655, Fax 65-6861-1312<br />

Kuala Lumpur, Malaysia: 60-3-8024-6773, Fax 60-3-8024-2180<br />

Hong Kong: 852-2595-0686, Fax 852-2505-5826<br />

B<br />

C<br />

Recognizing that residential sprinklers are being installed in many areas where<br />

conditions are not as described specifically in the code standards, TFP has<br />

generated a <strong>Residential</strong> Sprinkler Design Guide to help the fire sprinkler<br />

designer and installer correctly apply the sprinkler spacing and hydraulic<br />

calculations. This design guide covers many topics including spacing in sloped<br />

ceiling conditions, obstructions to the sprinkler pattern, location of<br />

sprinklers in odd shaped rooms or near heat sources, and much,<br />

C<br />

much more. This Design Guide can be obtained by contacting any<br />

<strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> Representative, or at our website at<br />

www.tyco-fire.com<br />

E<br />

A<br />

D<br />

B<br />

E<br />

A<br />

D<br />

A<br />

E<br />

A<br />

OBSTRUCTION<br />

CEILING<br />

D<br />

BlazeMaster is a registered trademark of Noveon IP Holding Corp.<br />

Caulk & Walk, No Block and <strong>Tyco</strong> are either registered trademarks or trademarks of <strong>Tyco</strong> and/or its affiliates in the United States<br />

and/or other countries. All other brand names, product names, or trademarks belong to their respective owners.<br />

A<br />

A<br />

© 2004 <strong>Tyco</strong> <strong>Fire</strong> <strong>Products</strong> LP. / All rights reserved. / Printed USA / TFP-Res / 4M / CPI / 07-04