Operating and inlet pressure<br />

CR-H, CRN-H, CRE-H, CRNE-H<br />

Operating range of the shaft seal<br />

The operating range of the shaft seal depends on operating<br />

pressure, pump type, type of shaft seal and liquid<br />

temperature. The following curves apply to clean water<br />

and water with anti-freeze liquids. For selecting the<br />

right shaft seal, see List of pumped liquids on page 100.<br />

CR(E), CRN(E) 1s H through CR 20 H<br />

p<br />

[bar]<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

p<br />

[psi]<br />

400<br />

300<br />

200<br />

100<br />

HQQE<br />

HQQE<br />

HQQV<br />

0<br />

-40 0 40 80 120 160 200 240 t [°F]<br />

-40 -20 0 20 40 60 80 100 t [°C]<br />

Fig. 21 Operating range of standard shaft seals for<br />

CR(E), CRN(E) 1s H to CR 20 H<br />

CR(E), CRN(E) 32 H through CR 90 H<br />

p<br />

[bar]<br />

30<br />

25<br />

20<br />

15<br />

10<br />

5<br />

0<br />

HQQE<br />

p<br />

[psi]<br />

500<br />

HQQE / HQQV HQQE<br />

400<br />

300<br />

KUHE / KUHV<br />

200<br />

KUBE / KUBV KUBE<br />

KUUE / KUUV<br />

100<br />

0<br />

-40 0 40 80 120 160 200 240 t [°F]<br />

KUUE<br />

KUUE<br />

KUUV<br />

-40 -20 0 20 40 60 80 100 t [°C]<br />

TM02 7537 1409<br />

TM04 4473 1409<br />

Shaft<br />

seal<br />

HQQE<br />

HQQV<br />

HUBE<br />

HUBV<br />

KUBE<br />

KUBV<br />

KUHE<br />

KUHV<br />

KUUE<br />

KUUV<br />

Des<strong>cr</strong>iption<br />

O-ring (balanced cartridge seal),<br />

SiC/SiC, EPDM<br />

O-ring (balanced cartridge seal),<br />

SiC/SiC, FKM<br />

O-ring (balanced cartridge seal),<br />

TC/carbon, EPDM<br />

O-ring (balanced cartridge seal),<br />

TC/carbon, FKM<br />

Metal bellows (balanced cartridge<br />

seal), TC/carbon, EPDM<br />

Metal bellows (balanced cartridge<br />

seal), TC/carbon, FKM<br />

Metal bellows (balanced cartridge<br />

seal), TC/carbon with embedded<br />

TC, EPDM<br />

Metal bellows (balanced cartridge<br />

seal), TC/carbon with embedded<br />

TC, FKM<br />

Metal bellows (balanced cartridge<br />

seal), TC/TC, EPDM<br />

Metal bellows (balanced cartridge<br />

seal), TC/TC, FKM<br />

TC = tungsten carbide.<br />

Max.<br />

temperature range<br />

[°F (C°)]<br />

– 22 °F to + 248 °F<br />

(– 30 °C to + 120 °C)<br />

– 4 °F to + 194 °F<br />

(– 30 °C to + 90 °C)<br />

+ 32 °F to + 248 °F<br />

(0 °C to + 120 °C)<br />

+ 32 °F to + 194 °F<br />

(0 °C to + 90 °C)<br />

+ 32 °F to + 248 °F<br />

(0 °C to + 120 °C)<br />

+ 32 °F to + 194 °F<br />

(0 °C to + 90 °C)<br />

+ 32 °F to + 194 °F<br />

(0 °C to + 90 °C)<br />

+ 32 °F to + 194 °F<br />

(0 °C to + 90 °C)<br />

– 22 °F to + 194 °F<br />

(–30 °C to + 90 °C)<br />

– 4 °F to + 194 °F<br />

(– 30 °C to + 90 °C)<br />

The pumping of liquids above 248 °F (120 °C) may<br />

result in periodical noise and reduced pump life.<br />

Standard CR-H, CRN-H pumps are not suitable for the<br />

pumping of liquids above 248 °F (120 °C) for long<br />

periods.<br />

See the Grundfos "Custom-built Pumps" Product Guide<br />

for information about pumps for extreme temperatures<br />

and special conditions.<br />

Fig. 22 Operating range of standard shaft seals for<br />

CR(E), CRN(E) 32 H to CR 90 H<br />

17