MAXIM<br />
INTEGRATED WATER HEATING SYSTEM<br />
TYPICAL CONSTRUCTION - MX MODEL<br />
FIGURE 17-1<br />
1. VENT STACK * 8. HANDHOLE CLEANOUT<br />
2. TEMPERATURE LIMITING DEVICE (set at 200°F) 9. UPPER OPERATING THERMOSTAT (set at 130°F)<br />
3. OPERATING THERMOSTAT (set at 120°F) 10. COLD WATER INLET & RETURN CONNECTION<br />
4. CONTROL SWITCH(es) AND FUSE(s) 11. DRAIN<br />
5. GAS VALVE 12. RELIEF VALVE<br />
6. GAS INLET 13. PRIMARY SAFETY CONTROL<br />
7. BURNER (MX model shown) 14. DIFFERENTIAL AIR PROVING SWITCH<br />
WARNING! Temperatures higher than 125°F increase the risk of scald injury!<br />
(* NOT FURNISHED BY PVI)<br />
IMPORTANT! Clearance to unprotected <strong>com</strong>bustible material must be 8"min. at top, sides and rear, and<br />
24" min. in front.<br />
PV500-17 07/13 2<br />
Section 17