University of California at Riverside<br />
Site Evaluation Survey<br />
Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />
900 University Avenue<br />
12. Clear Space at Doors - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />
Memo:<br />
See Sequence #11 for recommendations.<br />
Areas noted in compliance:<br />
60” min. clear space in direction of door swing.<br />
44” min. clear space opposite direction of door swing (48” with latch and closer).<br />
Minimum strike side clearance on PULL side of door: 24” exterior doors.<br />
Minimum strike side clearance on PUSH side of door: 0”.<br />
Areas not meeting new construction standards:<br />
Floor or landing is level and clear (2% max. slope). (3.1%.)<br />
Recommendation:<br />
None.<br />
Photo #UCR P5496 <strong>PE</strong> Utilities Building-12-1 (originally 19)<br />