University of California at Riverside<br />
Site Evaluation Survey<br />
Report: UCR P5496 <strong>PE</strong> Utilities Building in Riverside, CA<br />
900 University Avenue<br />
15. Toilet Grab Bars - Women’s Restroom at <strong>PE</strong> Utilities Building.<br />
Memo:<br />
Continuous grab bar. See Sequence #14 for additional recommendations.<br />
Areas noted in compliance:<br />
1-1/4” to 1-1/2” diameter of bars.<br />
1-1/2” clearance between bars and each wall or partition.<br />
The side grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor.<br />
The rear grab bar is securely attached and is mounted at 33” to the center of the bar above and parallel to the floor (for<br />
tank type toilets, 36” may be allowed if tank obstructs placement of bar).<br />
Side bar has 42” min. length.<br />
Side bar begins a max. of 12” from back wall.<br />
Back bar has 36” min. length.<br />
Back bar begins a max. of 6” from side wall.<br />
Bars are smooth with a min. edge radius of 1/8”.<br />
Grab bars do not rotate within their fittings.<br />
Min. structural strength to support 250 lb. point load.<br />
Surface of wall adjacent to grab bars are free of sharp or abrasive elements.<br />
Areas not meeting new construction standards:<br />
The front of the side grab bar extends 52” from back wall in multiple accommodation restroom. (50”.)<br />
Area directly above grab bars or proposed grab bars is free of protruding obstructions to a height of 18” (recessed<br />
items are allowed). (Toilet paper and seat cover dispensers.)<br />
Recommendation:<br />
Replace/Install grab bar.<br />
Relocate the seat cover dispenser away from the top of the grab bars or proposed grab bars.<br />
Relocate the toilet paper dispenser away from the top of the grab bars or proposed grab bars.<br />