3107750.014<br />

115 VAC 60 Hz 1 O<br />

USE COPPER CONDUCTORS<br />

ONLY<br />

FIELD WIRING<br />

FACTORY WIRING<br />

LINE SPLICE<br />

FREEZE<br />

CONTROL (N.O.)<br />

ANALOG DUCTED INSTALLATION INSTRUCTIONS<br />

12. RELAY KIT FIELD WIRING DIAGRAM<br />

BLACK<br />

WHITE<br />

GRN/YEL<br />

T3 T4<br />

RELAY BOARD<br />

K4 N.O.<br />

COM<br />

COOLING/FURNACE<br />

LO FAN<br />

3 AMP FUSE<br />

HI FAN<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

RED<br />

TAN<br />

BLUE<br />

YELLOW WHITE<br />

RED/WHT<br />

GREEN<br />

BLUE<br />

1<br />

BLACK<br />

2<br />

N/C 3<br />

RED<br />

4<br />

WHITE<br />

5<br />

GRY/YEL<br />

6<br />

FURNACE<br />

SOLAR/FILTER<br />

INDICATOR<br />

IF USED<br />

- 12 VDC<br />

+ POWER<br />

SUPPLY<br />

T-STAT<br />

ELECTRIC<br />

CONNECTION<br />

FROM A/C<br />

115VAC, 60Hz, 1PH<br />

R<br />

509 S. POPLAR ST.<br />

LAGRANGE, IN 46761<br />

E155095<br />

PART No. 3107541.009<br />

SERIAL No.<br />

FOR USE WITH AIR CONDITIONER:<br />

579, 590, 595, 600<br />

WITHOUT HEATSTRIP OPTION<br />

PASSED<br />

DIELECTRIC<br />

COOLING/FURNACE/HEAT STRIP<br />

3107759.015<br />

FREEZE<br />

CONTROL (N.O.)<br />

115VAC60Hz1O<br />

1 USE COPPER CONDUCTORS ONLY<br />

FIELD WIRING<br />

FACTORY WIRING<br />

LINE SPLICE<br />

T3<br />

RELAY BOARD<br />

K5<br />

BLACK<br />

WHITE<br />

GRN/YEL<br />

T4<br />

N.O.<br />

K4<br />

COM<br />

N.O.<br />

COM<br />

LO FAN<br />

3 AMP FUSE<br />

HI FAN<br />

GRAY 1<br />

N/C 2<br />

WHITE<br />

3<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

RED<br />

ORANGE<br />

TAN<br />

BLUE<br />

YELLOW WHITE<br />

RED/WHT<br />

GREEN<br />

BLUE<br />

1<br />

BLACK<br />

2<br />

N/C<br />

3<br />

RED<br />

4<br />

WHITE<br />

5<br />

GRY/YEL<br />

6<br />

HS<br />

115VAC, 60Hz, 1PH<br />

FURNACE<br />

SOLAR/FILTER<br />

INDICATOR<br />

IF USED<br />

-<br />

12 VDC<br />

+ POWER<br />

SUPPLY<br />

T-STAT<br />

ELECTRICAL<br />

CONNECTION<br />

FROM A/C<br />

R<br />

PART No. 3107541.017<br />

SERIAL No.<br />

509 S. POPLAR ST.<br />

LAGRANGE, IN 46761<br />

E155095<br />

FOR USE WITH AIR CONDITIONER:<br />

579, 590, 595, 600<br />

FOR A/C WITH OPTIONAL HEATSTRIP<br />

PASSED<br />

DIELECTRIC<br />

3107543.021<br />

FIELD WIRING<br />

FACTORY WIRING<br />

LINE SPLICE<br />

115 VAC 60 Hz 1 O<br />

USE COPPER CONDUCTORS<br />

ONLY<br />

COOLING/FURNACE/ HEAT PUMP<br />

T3<br />

RELAY BOARD<br />

K5<br />

BLACK<br />

WHITE<br />

GRN/YEL<br />

T4<br />

N.O.<br />

K4<br />

COM<br />

N.O.<br />

COM<br />

LO FAN<br />

3 AMP FUSE<br />

HI FAN<br />

BLUE/WHITE<br />

BLUE/WHITE<br />

BLACK<br />

RED<br />

VIOLET<br />

ORANGE<br />

BLUE<br />

YELLOW<br />

WHITE<br />

RED<br />

BLACK<br />

BLUE<br />

1<br />

BLACK<br />

2<br />

YELLOW<br />

3<br />

RED<br />

4<br />

WHITE<br />

5<br />

GRY/YEL<br />

6<br />

FURNACE<br />

SOLAR/FILTER<br />

INDICATOR<br />

IF USED<br />

-<br />

12 VDC<br />

+ POWER<br />

SUPPLY<br />

T-STAT<br />

ELECTRICAL<br />

CONNECTION<br />

FROM A/C<br />

115VAC, 60Hz, 1PH<br />

R<br />

E155095<br />

PART No. 3107546.008<br />

SERIAL No.<br />

509 S. POPLAR ST.<br />

LAGRANGE, IN 46761<br />

FOR USE WITH AIR CONDITIONER:<br />

59146<br />

FOR A/C WITH HEATPUMP<br />

PASSED<br />

DIELECTRIC<br />