2.5.22 CMP Instruction (Compare, Larger Than)<br />
a. When I001 and I002 turn from OFF to ON, CMP > instruction is executed. The value of Data Register<br />
No. R0002 is compared to the value of Data Register No. R001. When the comparison result is True, the<br />
output Relay is ON.<br />
b. TRUE R002>R001<br />
c. The value to be compared can be a decimal value.<br />
d. When the comparison result is false or when input is OFF, the output relay (O005) is OFF.<br />
e. When input is ON, CMP > instruction will be executed one time per scan time.<br />
CMP > Instruction<br />
2.5.23 CMP Instruction (Compare, Smaller Than)<br />
a. When I001 and I002 turn from OFF to ON, CMP < instruction is executed. The value of Data Register No.<br />
R0002 is compared to the value of Data Register No. R001. When the comparison result is True, the<br />
output Relay is ON.<br />
b. TRUE R002