Machine description – quick overview<br />
Machine control – Operating elements<br />
4.3 Machine control – Operating elements<br />
1<br />
A<br />
500A 49.9V<br />
<strong>Expert</strong><br />
2<br />
V<br />
M A<br />
Job Nr<br />
Hold<br />
3<br />
1<br />
11<br />
2<br />
10<br />
Spezial<br />
F<br />
Metal<br />
Rutil<br />
Basic<br />
MIG/MAG<br />
GMAW<br />
MSG-Löten<br />
GMA-Brazing<br />
Auftragsschw.<br />
GMA-Surfacing<br />
Fülldraht<br />
Flux-Cored<br />
Wire<br />
WIG/TIG<br />
SG2/3<br />
G3/4 Si1<br />
CrNi<br />
CuSi<br />
CuAl<br />
AlMg<br />
AlSi<br />
Al99<br />
0,8<br />
0,9<br />
1,0<br />
1,2<br />
1,6<br />
SP1<br />
SP2<br />
CO 2<br />
Ar/CO2<br />
Ar/O2<br />
Ar/CO<br />
2/O2<br />
Ar<br />
Ar/N2<br />
Ar/He/N2<br />
Ar/He<br />
Ar/He/O2<br />
Ar/He/CO<br />
2<br />
100%<br />
80-90% Ar<br />
91-99% Ar<br />
100%<br />
0-2% N 2<br />
15-70% He<br />
15-30% He<br />
Mode<br />
0<br />
4<br />
5<br />
1<br />
Super<strong>puls</strong><br />
E-Hand/MMA<br />
SP3<br />
Ar/He/H<br />
2/CO2<br />
1-5% H 2<br />
M 3.19<br />
9<br />
8<br />
7<br />
6<br />
S<br />
Figure 4-3<br />
Item Symbol Description 0<br />
1 Buttons switching digital display, left<br />
A Welding current (nominal, actual and hold values)<br />
Material thickness (nominal value)<br />
Wire speed (nominal, actual and hold values)<br />
Operating hour counter<br />
Selection of further welding parameters in lower programming levels.<br />
2 500A 49,9V Display, 16-digit<br />
Display of all welding parameters and their values<br />
3 Switching of the digital display Buttons, right<br />
V Welding voltage (nominal / actual values)<br />
M A Motor current (actual value)<br />
Job Nr JOB number<br />
Hold After each completed welding process, the last parameter values used for the<br />
welding process are shown on the display in the main program; the signal<br />
light is on.<br />
4 Button, Mode<br />
Select further programming levels<br />
(program steps mode, main program A mode, JOB Manager, JOB Info)<br />
5<br />
0<br />
Key switch for protection against unauthorised use<br />
1 Position “1” > changes possible,<br />
Position “0” > changes not possible.<br />
Please take note of chapter “Protecting welding parameters from unauthorised access”<br />
22<br />
099-004833-EW501<br />