Design and function<br />

MIG/MAG welding<br />

Spot welding<br />

1. 2.<br />

t<br />

I<br />

P START<br />

Figure 5-13<br />

P A<br />

P END<br />

t<br />

t<br />

NOTE<br />

The ignition time t start<br />

must be added to the spot time t 2<br />

.<br />

1st cycle<br />

• Press and hold torch trigger<br />

• Shielding gas is expelled (gas pre-flows)<br />

• Wire feed motor runs at "creep speed"<br />

• Arc ignites after the wire electrode makes contact with the workpiece,<br />

welding current is flowing (start program P START<br />

, spot time starts)<br />

• Slope to main program P A<br />

• After the set spot time elapses, slope goes to end program P END<br />

.<br />

• Wire feed motor stop welding.<br />

• Arc is extinguished after the pre-selected wire burn-back time elapses<br />

• Gas post-flow time elapses.<br />

2nd cycle<br />

• Release torch trigger<br />

Releasing the torch trigger (step 2) interrupts the welding process even if the spot time has not<br />

yet elapsed (slope to end program P END<br />

).<br />

46<br />

099-004833-EW501<br />

10.07.2012