MOTOREN<br />

NECKAR<br />

Electronically commutated<br />

MH 5...8 with integrated 1Q-Controller<br />

Terminal lead designation with terminal box K4 standard:<br />

External wiring<br />

*1 Rotating right<br />

*2 Brake active<br />

*3 No release<br />

Attention!<br />

Maximum connection voltage 26,5 V!<br />

Coded switch positions for internal operation:<br />

J1 Rotation direction: ON = Rotating left<br />

J2 Brake:<br />

ON = Short circuit brake inactive<br />

J3 Release:<br />

ON = Motor released<br />

J4 Int./Ext.-Set-point: ON = Internal set-point assignment<br />

J5 Ramp:<br />

ON = Set-point ramp inactive<br />

For external function selection plug corresponding<br />

bridges on the following positions –<br />

otherwise danger of short circuit!<br />

J1 Rotation direction:<br />

J2 Brake:<br />

J3 Release:<br />

J4 Int./ext. Set-point:<br />

OFF – Position<br />

OFF – Position<br />

OFF – Position<br />

OFF – Position = External set-point<br />

OFF – Position = assignment<br />

+VC: 24VDC +10/– 6 %<br />

Gnd: Supply earth<br />

Rev: Rotation reversal (High level 12..24V = Rotating left)<br />

Brake: Short circuit brake (High level 12..24V = Brake inactive)<br />

Enab.: Motor release (High level 12..24V = Function)<br />

S +: Set-point + (12V)<br />

S: Set-point input (0..10V)<br />

S –: Set-point earth<br />

Erro: Fault signal output (Open collector max. 45V 300mW)<br />

RI-A: Impulse output A-Spur (Open collector max. 45V 300mW) 2 Impulse/min –1<br />

RI-B: Impulse output B-Spur (Open collector max. 45V 300mW) 2 Impulse/min –1 120° Phase displacement<br />

D1: Ready for operation indicator<br />

D2: Fault / Excess current indicator<br />

Control range 30:1<br />

Speed range 100 – 3000 min –1<br />

Note:<br />

– The respective functions or operating elements should be reserved either only externally or internally as otherwise this can result<br />

in incorrect functions.<br />

– For internal set-point assignment the trimmer P2 is used for adjusting the speed.<br />

– For external set-point assignment the trimmer P2 is used for adjusting the maximum speed (set-point adjustment).<br />

– Trimmer P1 with an active ramp is used for adjusting the starting time.<br />