Heating Line <strong>Product</strong> Guide 435.0<br />

Thermocouple-Operated Single <strong>Valves</strong> Section<br />

<strong>Product</strong> Bulletin <strong>H17</strong><br />

Issue Date 1098<br />

<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong>® <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong><br />

The <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong>® pilot valves provide complete<br />

shutoff in the event that the flame heating the<br />

thermocouple is extinguished. Applications include<br />

room heaters, infrared heaters, salamanders, and<br />

refrigerators.<br />

<strong>H17</strong> models are also available with a higher ambient<br />

temperature, up to a maximum of 149°C (300°F), for<br />

use on commercial ovens, broilers, and other<br />

applications.<br />

Figure 1: <strong>H17</strong> <strong>Automatic</strong> <strong>Pilot</strong> Valve<br />

Features and Benefits<br />

❑ Compact Design<br />

❑ Versatile Mounting<br />

❑ Reliable<br />

Permits installation in dimensionally restricted<br />

applications<br />

Allows easy access to the reset button for<br />

lighting<br />

Proven by thousands of units in service<br />

© 1998 Johnson Controls, Inc. 1<br />

Code No. LIT-4350020<br />

www.johnsoncontrols.com


<strong>Product</strong> Overview<br />

Application<br />

The <strong>H17</strong> series valves provide complete shutoff in the<br />

event that the flame heating the thermocouple is<br />

extinguished. They are suitable for use with natural gas,<br />

Liquefied Petroleum (LP) gas, manufactured gas, mixed<br />

gas, or LP gas-air mixtures at pressures up to 35 mbar<br />

(0.5 psi). The <strong>H17</strong> is suitable for operation over a<br />

temperature range of -40 to 66°C (-40 to 150°F) for<br />

standard models. High temperature models are suitable<br />

for operation over a temperature range of -40 to 149°C<br />

(-40 to 300°F).<br />

Description<br />

<strong>H17</strong> valves are compact, straight-through aluminum<br />

valves with pipe sizes from 1/8 to 1/2 inch.<br />

<strong>H17</strong> valves do not have a flow interrupter, therefore,<br />

gas flows to both the main burner and pilot burner (if<br />

used) when the reset button is depressed. Where a<br />

pilot is not used, the pilot outlet is omitted and the tip of<br />

the thermocouple is inserted directly in the main burner<br />

flame.<br />

Mounting<br />

<strong>H17</strong> valves may be mounted in any position. This<br />

permits the reset button to be located in the most<br />

accessible location.<br />

Shutoff Valve<br />

"A"<br />

Reset Button<br />

"A" indicates possible<br />

locations for other controls.<br />

76.2 mm (3 in.)<br />

Sediment Trap<br />

"A"<br />

Thermocouple<br />

Lead<br />

<strong>Pilot</strong> Burner<br />

Gas Line<br />

Figure 2: Typical Installation<br />

2 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin


Dimensions<br />

B<br />

C<br />

C<br />

B<br />

A<br />

A<br />

Figure 3: <strong>H17</strong>D_ Dimension Drawing<br />

Figure 4: <strong>H17</strong>A, B, C_ Dimension Drawing<br />

Table 1: Maximum Ambient Temperatures and Dimensions<br />

<strong>Product</strong><br />

Number<br />

Maximum Ambient<br />

Temperature<br />

A Maximum<br />

Length<br />

B Maximum<br />

Width<br />

C Maximum<br />

Height<br />

°C °F mm in. mm in. mm in.<br />

<strong>H17</strong>AA 66 150<br />

<strong>H17</strong>AB 149 300<br />

<strong>H17</strong>BA 66 150 76 3 32 1.25 58 2.28<br />

<strong>H17</strong>BB 149 300<br />

<strong>H17</strong>CA 66 150<br />

<strong>H17</strong>CB 149 300<br />

<strong>H17</strong>DA 66 150 87 3.43 32 1.25 67 2.62<br />

<strong>H17</strong>DB 149 300 87 3.43 32 1.25 67 2.62<br />

<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 3


Flow Capacity<br />

1/8 x 1/8 in.<br />

1/4 x 1/4 in.<br />

3/8 x 3/8 in.<br />

1/2 x 1/2 in.<br />

40<br />

16.0<br />

30<br />

12.0<br />

20<br />

8.0<br />

6.0<br />

Pressure Drop<br />

mbar<br />

10<br />

7<br />

4.0<br />

2.8<br />

Pressure Drop<br />

in. W.C.<br />

5<br />

4<br />

2.0<br />

1.6<br />

3<br />

1.0<br />

2<br />

0.8<br />

1<br />

Air<br />

(sp gr = 1.0)<br />

0.4<br />

1 2 3 4 5 6 8 10 20 30 40 50 100 m 3 /h<br />

Natural Gas<br />

(sp gr = 0.64)<br />

1.5 2 3 4 6 10 20 40 60 100<br />

50 100 200 300 500 1000 2000 3000<br />

m 3 /h<br />

cf/h<br />

LP - Propane<br />

(sp gr = 1.53)<br />

1 2 3 4 6 10 20 40 60 100<br />

40 50 100 200 300 500 1000 2000 3000<br />

m 3 /h<br />

cf/h<br />

Capacity<br />

Figure 5: Maximum Flow Capacity<br />

4 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin


Ordering Information<br />

H 1 7 _ _ - _ _<br />

Customer Specific Requirements<br />

Capacity<br />

Inlet/Outlet<br />

1st Letter kW Btu/hr in. NPT 2nd Letter Power Unit<br />

A 18 60,000 1/8 x 1/8 A Standard<br />

B 22 75,000 1/4 x 1/4 B High Temperature<br />

C 37 125,000 3/8 x 3/8<br />

D 56 200,000 1/2 x 1/2<br />

The presence of a particular construction in this information does not guarantee its availability. Consult Johnson Controls for<br />

available constructions.<br />

Figure 6: Ordering Matrix<br />

<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 5


Notes<br />

6 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin


Notes<br />

<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 7


Specifications<br />

<strong>Product</strong><br />

Maximum Operating<br />

Pressure<br />

Valve Body<br />

Recommended<br />

Thermocouple<br />

Lead Lengths<br />

Ambient Temperature<br />

Inlet Pipe Sizes<br />

Outlet Pipe Sizes<br />

Types of Gas<br />

Packaging<br />

Bulk Pack Quantity 60<br />

Bulk Pack Weight<br />

<strong>H17</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong><br />

35 mbar (0.5 psi)<br />

Aluminum<br />

K15: 305 to 1,220 mm (12 to 48 in.)<br />

K16: 305 to 1,830 mm (12 to 72 in.)<br />

-40 to 66°C (-40 to 150°F) standard models<br />

-40 to 149°C (-40 to 300°F) high temperature models<br />

1/8, 1/4, 3/8, and 1/2 in. NPT<br />

1/8, 1/4, 3/8, and 1/2 in. NPT<br />

Natural, Liquefied Petroleum (LP), manufactured, mixed, or LP gas-air mixtures<br />

Bulk pack supplied to original equipment manufacturer (individual pack optional)<br />

12 kg (27 lb)<br />

Agency Listing IAS (AGA, CGA) Certificate Number C2154016<br />

UL File Number MH2926 (<strong>H17</strong>AA, BA, and CA Only)<br />

Specification Standards ANSI Standard Z21.20<br />

CAN1-6.4<br />

UL Standard 372<br />

The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these<br />

specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from<br />

misapplication or misuse of its products.<br />

Refer to the <strong>H17</strong> <strong>Series</strong> Technical Bulletin (LIT-121275) for necessary information on the installation, use, and servicing of this product.<br />

Controls Group<br />

www.johnsoncontrols.com<br />

507 E. Michigan Street FAN 435.0<br />

P.O. Box 423<br />

Heating Line <strong>Product</strong> Guide<br />

Milwaukee, WI 53201<br />

Printed in U.S.A.<br />

8 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!