Heating Line <strong>Product</strong> Guide 435.0<br />
Thermocouple-Operated Single <strong>Valves</strong> Section<br />
<strong>Product</strong> Bulletin <strong>H17</strong><br />
Issue Date 1098<br />
<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong>® <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong><br />
The <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong>® pilot valves provide complete<br />
shutoff in the event that the flame heating the<br />
thermocouple is extinguished. Applications include<br />
room heaters, infrared heaters, salamanders, and<br />
refrigerators.<br />
<strong>H17</strong> models are also available with a higher ambient<br />
temperature, up to a maximum of 149°C (300°F), for<br />
use on commercial ovens, broilers, and other<br />
applications.<br />
Figure 1: <strong>H17</strong> <strong>Automatic</strong> <strong>Pilot</strong> Valve<br />
Features and Benefits<br />
❑ Compact Design<br />
❑ Versatile Mounting<br />
❑ Reliable<br />
Permits installation in dimensionally restricted<br />
applications<br />
Allows easy access to the reset button for<br />
lighting<br />
Proven by thousands of units in service<br />
© 1998 Johnson Controls, Inc. 1<br />
Code No. LIT-4350020<br />
www.johnsoncontrols.com
<strong>Product</strong> Overview<br />
Application<br />
The <strong>H17</strong> series valves provide complete shutoff in the<br />
event that the flame heating the thermocouple is<br />
extinguished. They are suitable for use with natural gas,<br />
Liquefied Petroleum (LP) gas, manufactured gas, mixed<br />
gas, or LP gas-air mixtures at pressures up to 35 mbar<br />
(0.5 psi). The <strong>H17</strong> is suitable for operation over a<br />
temperature range of -40 to 66°C (-40 to 150°F) for<br />
standard models. High temperature models are suitable<br />
for operation over a temperature range of -40 to 149°C<br />
(-40 to 300°F).<br />
Description<br />
<strong>H17</strong> valves are compact, straight-through aluminum<br />
valves with pipe sizes from 1/8 to 1/2 inch.<br />
<strong>H17</strong> valves do not have a flow interrupter, therefore,<br />
gas flows to both the main burner and pilot burner (if<br />
used) when the reset button is depressed. Where a<br />
pilot is not used, the pilot outlet is omitted and the tip of<br />
the thermocouple is inserted directly in the main burner<br />
flame.<br />
Mounting<br />
<strong>H17</strong> valves may be mounted in any position. This<br />
permits the reset button to be located in the most<br />
accessible location.<br />
Shutoff Valve<br />
"A"<br />
Reset Button<br />
"A" indicates possible<br />
locations for other controls.<br />
76.2 mm (3 in.)<br />
Sediment Trap<br />
"A"<br />
Thermocouple<br />
Lead<br />
<strong>Pilot</strong> Burner<br />
Gas Line<br />
Figure 2: Typical Installation<br />
2 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin
Dimensions<br />
B<br />
C<br />
C<br />
B<br />
A<br />
A<br />
Figure 3: <strong>H17</strong>D_ Dimension Drawing<br />
Figure 4: <strong>H17</strong>A, B, C_ Dimension Drawing<br />
Table 1: Maximum Ambient Temperatures and Dimensions<br />
<strong>Product</strong><br />
Number<br />
Maximum Ambient<br />
Temperature<br />
A Maximum<br />
Length<br />
B Maximum<br />
Width<br />
C Maximum<br />
Height<br />
°C °F mm in. mm in. mm in.<br />
<strong>H17</strong>AA 66 150<br />
<strong>H17</strong>AB 149 300<br />
<strong>H17</strong>BA 66 150 76 3 32 1.25 58 2.28<br />
<strong>H17</strong>BB 149 300<br />
<strong>H17</strong>CA 66 150<br />
<strong>H17</strong>CB 149 300<br />
<strong>H17</strong>DA 66 150 87 3.43 32 1.25 67 2.62<br />
<strong>H17</strong>DB 149 300 87 3.43 32 1.25 67 2.62<br />
<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 3
Flow Capacity<br />
1/8 x 1/8 in.<br />
1/4 x 1/4 in.<br />
3/8 x 3/8 in.<br />
1/2 x 1/2 in.<br />
40<br />
16.0<br />
30<br />
12.0<br />
20<br />
8.0<br />
6.0<br />
Pressure Drop<br />
mbar<br />
10<br />
7<br />
4.0<br />
2.8<br />
Pressure Drop<br />
in. W.C.<br />
5<br />
4<br />
2.0<br />
1.6<br />
3<br />
1.0<br />
2<br />
0.8<br />
1<br />
Air<br />
(sp gr = 1.0)<br />
0.4<br />
1 2 3 4 5 6 8 10 20 30 40 50 100 m 3 /h<br />
Natural Gas<br />
(sp gr = 0.64)<br />
1.5 2 3 4 6 10 20 40 60 100<br />
50 100 200 300 500 1000 2000 3000<br />
m 3 /h<br />
cf/h<br />
LP - Propane<br />
(sp gr = 1.53)<br />
1 2 3 4 6 10 20 40 60 100<br />
40 50 100 200 300 500 1000 2000 3000<br />
m 3 /h<br />
cf/h<br />
Capacity<br />
Figure 5: Maximum Flow Capacity<br />
4 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin
Ordering Information<br />
H 1 7 _ _ - _ _<br />
Customer Specific Requirements<br />
Capacity<br />
Inlet/Outlet<br />
1st Letter kW Btu/hr in. NPT 2nd Letter Power Unit<br />
A 18 60,000 1/8 x 1/8 A Standard<br />
B 22 75,000 1/4 x 1/4 B High Temperature<br />
C 37 125,000 3/8 x 3/8<br />
D 56 200,000 1/2 x 1/2<br />
The presence of a particular construction in this information does not guarantee its availability. Consult Johnson Controls for<br />
available constructions.<br />
Figure 6: Ordering Matrix<br />
<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 5
Notes<br />
6 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin
Notes<br />
<strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin 7
Specifications<br />
<strong>Product</strong><br />
Maximum Operating<br />
Pressure<br />
Valve Body<br />
Recommended<br />
Thermocouple<br />
Lead Lengths<br />
Ambient Temperature<br />
Inlet Pipe Sizes<br />
Outlet Pipe Sizes<br />
Types of Gas<br />
Packaging<br />
Bulk Pack Quantity 60<br />
Bulk Pack Weight<br />
<strong>H17</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong><br />
35 mbar (0.5 psi)<br />
Aluminum<br />
K15: 305 to 1,220 mm (12 to 48 in.)<br />
K16: 305 to 1,830 mm (12 to 72 in.)<br />
-40 to 66°C (-40 to 150°F) standard models<br />
-40 to 149°C (-40 to 300°F) high temperature models<br />
1/8, 1/4, 3/8, and 1/2 in. NPT<br />
1/8, 1/4, 3/8, and 1/2 in. NPT<br />
Natural, Liquefied Petroleum (LP), manufactured, mixed, or LP gas-air mixtures<br />
Bulk pack supplied to original equipment manufacturer (individual pack optional)<br />
12 kg (27 lb)<br />
Agency Listing IAS (AGA, CGA) Certificate Number C2154016<br />
UL File Number MH2926 (<strong>H17</strong>AA, BA, and CA Only)<br />
Specification Standards ANSI Standard Z21.20<br />
CAN1-6.4<br />
UL Standard 372<br />
The performance specifications are nominal and conform to acceptable industry standards. For application at conditions beyond these<br />
specifications, consult the local Johnson Controls office. Johnson Controls, Inc. shall not be liable for damages resulting from<br />
misapplication or misuse of its products.<br />
Refer to the <strong>H17</strong> <strong>Series</strong> Technical Bulletin (LIT-121275) for necessary information on the installation, use, and servicing of this product.<br />
Controls Group<br />
www.johnsoncontrols.com<br />
507 E. Michigan Street FAN 435.0<br />
P.O. Box 423<br />
Heating Line <strong>Product</strong> Guide<br />
Milwaukee, WI 53201<br />
Printed in U.S.A.<br />
8 <strong>H17</strong> <strong>Series</strong> <strong>BASO</strong> <strong>Automatic</strong> <strong>Pilot</strong> <strong>Valves</strong> <strong>Product</strong> Bulletin