07.11.2014 Views

Wireless Flexibility - Siemens

Wireless Flexibility - Siemens

Wireless Flexibility - Siemens

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C l e a n P o w e r I n p u t<br />

The Robicon Perfect Harmony drive meets the most stringent<br />

harmonic requirements for voltage and current distortion.<br />

3 Protects other on-line equipment from harmonic<br />

disturbance (computers, telephones, lighting ballast)<br />

3 Prevents “cross-talk” with other sensitive control and<br />

variable frequency drives<br />

3 Avoids costly harmonic filters and associated<br />

resonance problems<br />

P o w e r Q u a l i t y O u t p u t<br />

3<br />

3<br />

3<br />

No common mode motor insulation stress<br />

- Perfect Harmony includes an isolation transformer<br />

integral in common mode dissipation<br />

- Motor does not require 10 to 13 kV insulation<br />

Perfect Harmony includes an isolation transformer<br />

integral in common mode dissipation<br />

Motor does not require 10 to 13 kV insulation<br />

3<br />

3<br />

3<br />

3<br />

3<br />

3<br />

Drive is compatible with both new and existing 1.0<br />

service factor induction or synchronous motors from any<br />

manufacturer without any special design considerations<br />

No significant VFD induced torques pulsations –<br />

even at low speeds<br />

No need for expensive flexible couplings<br />

No additional VFD induced motor heating<br />

No cable length restrictions<br />

Allows standard motor insulation – decreasing the<br />

motor insulation requirements to less than an acrossthe-line<br />

start motor<br />

T y p i c a l a p p l i c a t i o n s<br />

3<br />

3<br />

3<br />

3<br />

3<br />

Retrofit<br />

Power generation - can ride through voltage<br />

dips or power outages<br />

Water/Wastewater - provides high output voltage<br />

at low power<br />

Oil & Gas - Small footprint, high availability<br />

Pulp/Paper - provides high output voltage at low power<br />

T e c h n i c a l S p e c i f i c a t i o n s<br />

General<br />

Power semiconductors<br />

Line-side converter<br />

Motor-side converter<br />

Closed-loop control<br />

Drive quadrants<br />

Potential separation:<br />

Power section<br />

Open- and closed-loop<br />

control<br />

Permissible humidity<br />

rating<br />

Noise level<br />

Efficiency<br />

(standard version)<br />

Regulation<br />

compliances<br />

Paint finish<br />

IGBTs; diodes<br />

18- to 36-pulse diode rectifier<br />

(standard)<br />

Multi-level converter (PWM) with<br />

IGBT power modules<br />

Sensorless closed-loop control,<br />

fully digital with signal processor<br />

Driving: 2 directions of rotation<br />

(2 quadrant), 4 quadrant option<br />

Fiber-optic cable<br />

Relative air humidity < 95% noncondensing<br />

Approx. 75 dB (A)<br />

96% at the rated operating point<br />

including transformer<br />

IEEE, ANSI, NEMA, UL, CSA, CE<br />

ANSI 61 Gray<br />

Degree of protection Acc. to DIN VDE 0470,<br />

IEC 60529, EN 60529<br />

- Standard IP31 (air-cooling) IP52 (watercooling)<br />

NEMA 1 (air-cooling)<br />

NEMA 12 (water-cooling)<br />

- Optional IP42 (air-cooling)<br />

Cooling Type<br />

Air-cooled<br />

Forced-air cooling with<br />

integrated fans<br />

Permissible ambient and cooling, medium temperature<br />

- In operation 0ºC to + 40ºC: 100% load capability<br />

+40ºC to 50ºC: current derating<br />

- During storage -25ºC to +55ºC<br />

- During transport -25ºC to +70ºC<br />

Water-cooled Deionized water with integrated<br />

water-to-water heat exchanger<br />

Permissible ambient temperature<br />

- In operation +0ºC to + 40ºC<br />

- During storage -25ºC to + 55ºC<br />

(without deionized water)<br />

- During transport -25ºC to + 70ºC<br />

(without deionized water)<br />

Permissible cooling medium temperature (raw water)<br />

- Intake +5ºC to 35ºC<br />

- Outlet Max. +40ºC<br />

Supply Data<br />

Standard<br />

Special option<br />

Control voltage<br />

2.3 to 15 kV<br />

< 2.3 and > 12 kV<br />

1 Ph, 120 VAC or integrated<br />

to auxiliary supply<br />

ideas singapore | 2008 15