9. Data sheet motors<br />
Operation instructions motors<br />
Connection<br />
When connecting the electric motors to the available supply, the information on the rating plate<br />
must be observed and compared with the enclosed connection diagram. One speed motor<br />
normally has a terminal box containing a terminal board with 6 terminals.<br />
This Voltage given 380/230V<br />
means:<br />
Star connection for higher voltage.<br />
Example: 380V<br />
Delta connection for lower voltage.<br />
Example: 230V<br />
A.C. motor<br />
Every motor is provided with a connection diagram in the terminal box.<br />
Connection of the supply must be carried out by an expert. Choose cable crosssections<br />
in accordance with the rated current. Supply cables must be stress relieved.<br />
Earth leads must be connected to the marked earth screw in accordance with VDE<br />
0100. Use original gaskets when closing the terminal box. Cable entries which are not<br />
to be used must be sealed up dust and watertight.<br />
21.03.2012 25 F03 0672 500/02 EN