AN1035<br />
<strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong><br />
Paxton Access<br />
Overview<br />
<strong>Net2</strong> c<strong>an</strong> monitor whether the <strong>intruder</strong> <strong>alarm</strong> is armed or disarmed. If the <strong>alarm</strong> is armed, the <strong>Net2</strong><br />
will only allow access to users who have the authority to disarm the <strong>system</strong>. All other users will be<br />
denied access, regardless of their normal access rights.<br />
02/05/2007<br />
When allowing the first authorised access, <strong>Net2</strong> will send a signal to disarm the <strong>alarm</strong> automatically.<br />
If this is successful the door is opened <strong>an</strong>d st<strong>an</strong>dard access rights for all users are then allowed.<br />
NOTE: To allow the integration to work, the <strong>intruder</strong> <strong>alarm</strong> p<strong>an</strong>el must be able to accept a<br />
momentary keyswitch input to arm <strong>an</strong>d disarm the <strong>system</strong> <strong>an</strong>d there must be <strong>an</strong> output that<br />
provides a signal when the <strong>alarm</strong> is armed.<br />
Configuring <strong>Net2</strong> to allow <strong>alarm</strong> integration<br />
To activate the <strong>Net2</strong> <strong>alarm</strong> integration software the correct check box must be ticked on the features<br />
tab in the <strong>Net2</strong> server configuration utility.<br />
Configuring a door to control the <strong>intruder</strong> <strong>alarm</strong><br />
To enable <strong>alarm</strong> integration at a specific door, select the ACU, go to the <strong>intruder</strong> <strong>alarm</strong> tab <strong>an</strong>d check<br />
the tick box. You must then define the following options:<br />
Define if the set/unset indication from the <strong>intruder</strong> <strong>alarm</strong> is <strong>an</strong> open or closed loop<br />
Specify the time period for which the <strong>Net2</strong> relay contacts need to close to ch<strong>an</strong>ge<br />
the <strong>intruder</strong> <strong>alarm</strong> state (0.1 to 10 seconds)<br />
Open the door on the third attempt even if the <strong>alarm</strong> c<strong>an</strong>not be disarmed by <strong>Net2</strong><br />
V4<br />
Set the time period for the confirmation button - if fitted. (up to 120 secs)<br />
Specify <strong>an</strong> alternative reader operating mode when the <strong>alarm</strong> is active - if required<br />
AN1035 - <strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong><br />
1
Allowing users to control the <strong>alarm</strong> <strong>system</strong><br />
Once <strong>intruder</strong> <strong>alarm</strong> software is installed, the following tick box appears in each user record. This<br />
must be ticked to give the user the authority to set/unset the <strong>alarm</strong>.<br />
Disarming the <strong>alarm</strong><br />
If the <strong>alarm</strong> is armed <strong>an</strong>d <strong>an</strong> authorised user presents their card to the IN reader.<br />
The reader will acknowledge the card but the amber <strong>an</strong>d red LED’s will flash to indicate<br />
that the <strong>alarm</strong> is set<br />
The green LED will flash when the <strong>intruder</strong> <strong>alarm</strong> has been disarmed by <strong>Net2</strong><br />
The door will open in the normal way<br />
<strong>Net2</strong><br />
V4<br />
The reader will now work as normal for all users until the <strong>alarm</strong> is armed<br />
AN1035 - <strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong>
Arming the <strong>alarm</strong><br />
There are 3 methods that c<strong>an</strong> be used to arm the <strong>system</strong>. (To conform to DD243 regulations<br />
method 2 should be used.)<br />
1) Using proximity reader(s) <strong>an</strong>d one ACU - When <strong>an</strong> authorised user presents their card to the<br />
designated reader, they are given a user specified time period to press a button installed for the<br />
purpose of confirming that the <strong>alarm</strong> is to be armed. Once pressed the <strong>intruder</strong> <strong>alarm</strong> will arm<br />
itself. If the button is not pressed the door will be released in the normal way, leaving the <strong>alarm</strong><br />
status unch<strong>an</strong>ged.<br />
NOTE: You c<strong>an</strong> use two readers <strong>with</strong> this setup (Read In & Read Out) as per normal access control.<br />
The push button is still required to confirm the <strong>alarm</strong> set request.<br />
From <strong>intruder</strong> <strong>alarm</strong> volt free<br />
status output<br />
To set <strong>alarm</strong>:<br />
Present token & push button<br />
To <strong>intruder</strong> <strong>alarm</strong> momentary<br />
key switch input<br />
Reader<br />
<strong>Net2</strong> door access control unit<br />
<strong>Net2</strong><br />
V4<br />
AN1035 - <strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong>
2) Using two readers <strong>an</strong>d two ACUs - One ACU is used for normal building access <strong>an</strong>d to unset the<br />
<strong>alarm</strong>. A second ACU is dedicated to the <strong>intruder</strong> <strong>alarm</strong> <strong>an</strong>d is used to arm the <strong>system</strong>.<br />
Only authorised <strong>alarm</strong> users should be given access rights for the reader used for setting the <strong>alarm</strong><br />
<strong>an</strong>d so no confirmation button is required.<br />
This method should be used to ensure compli<strong>an</strong>ce <strong>with</strong> DD243.<br />
From <strong>intruder</strong> <strong>alarm</strong><br />
volt free status output<br />
For access control <strong>an</strong>d<br />
unsetting the <strong>alarm</strong><br />
To <strong>intruder</strong> <strong>alarm</strong> momentary<br />
key switch input<br />
Reader<br />
<strong>Net2</strong> door access control unit<br />
For setting the <strong>alarm</strong><br />
<strong>Net2</strong><br />
V4<br />
Reader<br />
<strong>Net2</strong> door access control unit<br />
AN1035 - <strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong>
3) Using a keypad <strong>an</strong>d ACU - The * key on the keypad c<strong>an</strong> be used instead of fitting a<br />
confirmation push button. To set the <strong>alarm</strong> the authorised user first presses the * key<br />
<strong>an</strong>d will then be given 7 seconds to enter their PIN arming the <strong>system</strong>. The next valid<br />
PIN from <strong>an</strong> authorised user will attempt to unset the <strong>alarm</strong> in the normal way.<br />
From <strong>intruder</strong> <strong>alarm</strong> volt free<br />
status output<br />
To <strong>intruder</strong> <strong>alarm</strong> momentary<br />
key switch input<br />
Keypad<br />
<strong>Net2</strong> door access control unit<br />
Import<strong>an</strong>t Notes<br />
Relay 2 is used to set/unset the <strong>alarm</strong> <strong>an</strong>d so the relay 2 toggle option under Reader action is<br />
greyed out. Any ACU that is used for <strong>alarm</strong> integration must have the lock release connected to<br />
relay 1; relay 2 c<strong>an</strong>not be used to toggle.<br />
If the door on the ACU is normaly held open <strong>with</strong> a timezone, the ACU will not unlock the door<br />
until the <strong>intruder</strong> <strong>alarm</strong> has been disarmed.<br />
<strong>Net2</strong><br />
V4<br />
AN1035 - <strong>Integrating</strong> <strong>Net2</strong> <strong>with</strong> <strong>an</strong> <strong>intruder</strong> <strong>alarm</strong> <strong>system</strong>