Operating conditions<br />

<strong>TP</strong>, <strong>TP</strong>D, <strong>TP</strong>E<br />

Pressure conditions<br />

System and test pressures<br />

Pressure<br />

System pressure Test pressure<br />

[bar] [MPa] [bar] [MPa]<br />

PN 6 6 0.6 10 1.0<br />

PN 6 / PN 10 10 1.0 16 1.6<br />

PN 16 16 1.6 24 2.4<br />

PN 25 25 2.5 38 3.8<br />

Sound pressure level<br />

Max. sound pressure level [dB(A)] - ISO 3743<br />

Motor<br />

[kW]<br />

Three-phase motors<br />

2-pole<br />

4-pole<br />

0.12 - -<br />

0.25 - 45<br />

0.37 57 45<br />

0.55 56 45<br />

0.75 57 49<br />

1.1 63 53<br />

1.5 64 53<br />

2.2 65 55<br />

3.0 64 55<br />

4.0 68 57<br />

5.5 67 62<br />

7.5 73 62<br />

11.0 70 66<br />

15.0 70 66<br />

18.5 70 63<br />

22.0 70 63<br />

30.0 71 65<br />

37.0 71 65<br />

45.0 75 65<br />

55.0 75 68<br />

75.0 77 71<br />

90.0 77 71<br />

110.0 81 75<br />

132.0 81 75<br />

160.0 81 75<br />

200.0 81 75<br />

250.0 86 77<br />

315.0 - 77<br />

The audible noise from <strong>TP</strong> pumps is primarily noise<br />

from the motor fan. The selection of <strong>TP</strong>E pumps will<br />

reduce the noise at partial load, as the motor, and consequently,<br />

the motor fan runs at a lower speed. Possible<br />

flow noise from control valves is also reduced at<br />

partial load in the case of the <strong>TP</strong>E pump.<br />

Ambient temperature<br />

MG – EFF1-motors:<br />

1.1-11 kW motors, 2-pole<br />

1.1-4 kW, 4-pole<br />

Siemens – EFF1-motors:<br />

15-90 kW motors, 2-pole<br />

5.5-90 kW motors, 4-pole<br />

Other motor sizes:<br />

Storage:<br />

If the ambient temperature exceeds above maximum<br />

values or if the motor is located more than 1000 metres<br />

above sea level, the motor output (P2) must be reduced<br />

due to the low density and consequent low cooling<br />

effect of the air. In such cases, it may be necessary to<br />

use an oversize motor with a higher rated output.<br />

Key<br />

–30 to +60°C<br />

–30 to +55°C<br />

–30 to +40°C<br />

Down to –30°C<br />

P2<br />

[%]<br />

1<br />

100<br />

2<br />

90<br />

80<br />

3<br />

70<br />

60<br />

50<br />

20 25 30 35 40 45 50 55 60 65 70 75 80<br />

t [°C]<br />

1000 2250 3500 4750 m<br />

Fig. 1 Relationship between motor output (P 2 )<br />

and altitude<br />

Pos<br />

1<br />

Description<br />

Siemens – EFF1-motors:<br />

15-90 kW motors, 2-pole<br />

5.5-90 kW motors, 4-pole<br />

MG – EFF1-motors:<br />

2 1.1-11 kW motors, 2-pole<br />

1.1-4 kW, 4-pole<br />

3 Other motor sizes<br />

TM03 2479 4405<br />

16

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!