TRC Skirting Heating shown on page 87<br />

Model<br />

Height<br />

A (mm)<br />

Width<br />

B (mm)<br />

Watts<br />

∆t 50ºc<br />

Btu’s<br />

∆t 50ºc<br />

Price<br />

Ex VAT<br />

5<br />

Year Guarantee<br />

Year Guarantee<br />

Price<br />

Inc VAT<br />

All stocked radiators have prices<br />

listed in purple and will be<br />

delivered in 3 - 5 working days.<br />

TRSK500 179 500 280 956 £82.00 £98.40<br />

TRSK100 179 1000 561 1914 £157.00 £188.40<br />

TRSK150 179 1500 841 2870 £227.00 £272.40<br />

TRSK200 179 2000 1121 3827 £299.00 £358.80<br />

TRSKCS100 1000 casing only £71.00 £85.20<br />

TRSKVVLH left hand valve box/end cap kit £42.00 £50.40<br />

TRSKVVRH right hand valve box/end cap kit £42.00 £50.40<br />

TRSKVVCC centre valve cover £21.00 £25.20<br />

TRSKIN90 internal 90 corner £21.00 £25.20<br />

TRSKEX90 external 90 corner £21.00 £25.20<br />

TRSKIN135 internal 135 corner £21.00 £25.20<br />

TRSKEX135 external 135 corner £21.00 £25.20<br />

TRC Skirting Heating Guide<br />

1. Work out your required heat output. For a more detailed explanation please see pages 160 - 161 or visit our website at<br />

www.theradiatorcompany.co.uk.<br />

2. Decide which walls are best suited to the positioning of the skirting elements in relationship to your existing or planned pipe-work.<br />

3. Measure the length of walls where the lengths are to be fitted.<br />

(Please note it is not necessary to run the elements along the complete wall).<br />

4. Use a combination of the various lengths available to provide the required heat output with a minimum number of joints. A 1000mm<br />

casing only length, suitable for cutting to size, is also available for making good where required. Use corners as required.<br />

5. When fitting Thermostatic Radiator Valves leave sufficient distances between the end valve box and the wall to allow air movement.<br />

6. Allow sufficient distances from room corners to fit corner attachments.<br />

Please Note:<br />

Joining strips are supplied with all skirting lengths ordered, 1 per length.<br />

38<br />

76<br />

172<br />

152<br />

A<br />

99<br />

31<br />

B<br />

74.5<br />

joining strip<br />

valve box / end cap<br />

centre valve cover<br />

126.5<br />

125 81.5 92.5<br />

60.5<br />

51<br />

90° external corner<br />

90° internal corner 135° internal corner 135° external corner<br />

Important Note:<br />

Valves are not supplied with TRC Skirting Heating. When fitting Thermostatic valves the valve head will protrude from the side of the<br />

valve box. Motorised or regular valves can be concealed within the valve box. TRC Skirting Heating uses 22mm UK connections. If fitting<br />

straight runs of 4 metres or longer we recommend that expansion joints are used. These are readily available from heating merchants.<br />

www.theradiatorcompany.co.uk ' 01342 302250<br />