Project: <strong>SSETI</strong> <strong>Express</strong><br />

Doc : <strong>SSETI</strong> Ex press Phase D – <strong>Integration</strong> <strong>Logbook</strong><br />

Phase : Phase D<br />

Date : Started 5 th October 2004<br />

Ref : EXPRESS_D_ESA_<strong>Integration</strong>_<strong>Logbook</strong>.doc<br />

2) Test setup<br />

For external powering<br />

1) Ready to supply 28 volts to pins 13 and 14 of the external power supply connecter,<br />

with the ground running through pin 5 of the OBC debug connector (or to the ASAP<br />

ring if it is accessible).<br />

2) Current limit set to maximum, and run the positive line through a digital ammeter.<br />

3) The EPS ARM plug should NOT be connected.<br />

4) The S-Band ARM plug should be present.<br />

5) When the spacecraft should be powered up, simply turn the power supply on.<br />

For internal powering<br />

1) The external power connector should be left empty. Ready to connect the EPS ARM<br />

plug to turn the spacecraft on.<br />

2) The S-Band ARM plug should be present.<br />

3) When the spacecraft should be powered up then apply the ABF connector, wait for<br />

five seconds (to charge the timer skip capacitor), disconnect it, and then reapply. The<br />

spacecraft should boot-up. (If the last boot-up was within the last 30 minutes then<br />

only one application is necessary as the capacitor should still be charged.<br />

Groundstation<br />

1) Should already be set up internally – don’t change anything.<br />

2) Ensure that the ICOM is connected to COM port 1<br />

3) Ensure that the TNC is connected to COM port 4<br />

4) Turn the power supply on and check all the lights come on<br />

5) Run PCR-100 controller, should see a non-zero signal (noise). If communication is<br />

not possible then a dialogue box will appear to inform<br />

6) Run term.exe and ensure it is set to 56k7<br />

7) Connect and send a test TC, should see the PTT lights come on on the UHF side of the<br />

TNC and the UHF radio<br />

8) Run DTMF.exe and make sure that the audio spectrum is present (noise)<br />