2 Mechanical Installation VLT ® Micro Drive FC 51 Operating Instructions<br />
2.3.1 Mechanical Dimensions<br />
2<br />
Illustration 2.1: Mechanical dimensions.<br />
NB!<br />
A template for drilling can be found on the flap of the packaging.<br />
Power (kW) Height (mm) Width (mm) Depth 1)<br />
(mm)<br />
Max.<br />
Weight<br />
Frame<br />
1 X 200-240 3 X<br />
3 X<br />
A (incl. decoupling<br />
plate)<br />
A<br />
V 200 -240 V 380-480 V<br />
a B b C Kg<br />
M1 0.18 - 0.75 0.25 - 0.75 0.37 - 0.75 150 205 140.4 70 55 148 1.1<br />
M2 1.5 1.5 1.5 - 2.2 176 230 166.4 75 59 168 1.6<br />
M3 2.2 2.2 -3.7 3.0 - 7.5 239 294 226 90 69 194 3.0<br />
Table 2.1: Mechanical Dimensions<br />
1)<br />
For LCP with potentiometer, please add 7.6 mm.<br />
NB!<br />
DIN rail mounting kit is available for M1 frame . Please use ordering number 132B0111.<br />
10 MG.02.A4.02 - VLT ® is a registered Danfoss trademark