Download - VINH THIEN INDUSTRY Co.,ltd
Download - VINH THIEN INDUSTRY Co.,ltd
Download - VINH THIEN INDUSTRY Co.,ltd
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
6 Parameter Overview VLT ® Micro Drive FC 51 Operating Instructions<br />
6<br />
6.2.9 4-** Limits/Warnings<br />
Parameter Number Parameter Description Default Value 2 Setup Change During Operation <strong>Co</strong>nversion Index Type<br />
4 - 10 Motor Speed Direction [2] Both directions All set-ups FALSE - Uint8<br />
4 - 12 Motor Speed Low Limit [Hz] 0 Hz All set-ups FALSE -1 Uint16<br />
4 - 14 Motor Speed High Limit [Hz] 65 Hz All set-ups FALSE -1 Uint16<br />
4 - 16 Torque Limit Motor Mode 150% All set-ups TRUE 0 Uint16<br />
4 - 17 Torque Limit Generator Mode 100% All set-ups TRUE 0 Uint16<br />
4 - 50 Warning Current Low 0 A All set-ups TRUE -2 Uint32<br />
4 - 51 Warning Current High 26 A All set-ups TRUE -2 Uint32<br />
4 - 58 Missing Motor Phase Function [1] On All set-ups FALSE - Uint8<br />
4 - 61 Bypass Speed From [Hz] 0 Hz All set-ups TRUE -1 Uint16<br />
4 - 63 Bypass Speed To [Hz] 0 Hz All set-ups TRUE -1 Uint16<br />
50 MG.02.A4.02 - VLT ® is a registered Danfoss trademark