pdf, 3101 Kbytes
pdf, 3101 Kbytes
pdf, 3101 Kbytes
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
BOD-Measurement<br />
Technical data<br />
Meas. principle<br />
Inductive stirring system<br />
Manometric; mercury-free;<br />
electronic pressure sensor<br />
Ranges 0 - 40, 0 - 80, 0 - 200,<br />
[mg/l O 2 ] 0 - 400, 0 - 800,<br />
0 - 2000, 0 - 4000 mg/l<br />
Accuracy* 0.5 % full scale at 20°C<br />
Applications BOD 5 , BOD 7 , OECD 301 F ...<br />
Result display<br />
Measurement<br />
parameter display<br />
Measurement<br />
period<br />
Auto result<br />
storage<br />
Storage<br />
interval<br />
Automatic<br />
start function<br />
Power<br />
supply<br />
BOD [mg/l]; 4 - digits ; 7 - segment LED<br />
BOD-range, volume, duration,<br />
time of measurement<br />
User-selectable, between<br />
1 and 28 days<br />
Up to 28 results, depending<br />
on measurement period<br />
– hourly (1 day)<br />
– every 2 hours (2 days)<br />
– daily (3-28 days)<br />
– After temperature<br />
equalisation of samples<br />
– Can be switched off<br />
3 alkaline-manganese<br />
batteries (“Baby” cells/size “C”)<br />
Battery life 1 year (normal use as BOD 5 meter –<br />
max. one reading a day); early warning<br />
before battery fails<br />
Interface<br />
RS 232 for printer or PC connection<br />
Clock<br />
Real-time clock<br />
Protection class IP 54 (sensor head)<br />
Dimensions<br />
375 x 195 x 230 mm<br />
(L x W x H) including stirring unit<br />
Weight<br />
3850 g, unit with bottles<br />
5750 g, complete with stirring unit<br />
Housing<br />
ABS<br />
Approval<br />
CE<br />
* No standard is available to check the accuracy of respirometric oxygen uptake<br />
measurement. Tests with a glucose-glutamic acid solution having a known theoretical<br />
BOD have shown that the variation is approximately 5% in the range of 50…100 mg/l BOD,<br />
and 3% for higher range. Minimum Response or sensitivity of respirometric systems is about<br />
0.05 … 1 mg/l.<br />
The microprocessor-controlled AQUALYTIC ® inductive stirring<br />
system is non-wearing and maintenance-free. In other words,<br />
there are no moving parts in the system.<br />
At regular intervals, the magnetic stirring rods are accelerated<br />
and slowed down again, taking them up to maximum speed<br />
and back down again. This ensures the centralization of the<br />
stirring rods.<br />
Stirring rods that move away from the centre of the bottle are<br />
re-centered quickly and reliably.<br />
The inductive actuation system guarantees maintenance-free<br />
operation (no need to replace drive belts or burnt-out drive<br />
motors) for many years.<br />
Highlights<br />
■ Maintenance-free and non-wearing<br />
■ Regular change in stirring speed<br />
■ Automatic centering of stirring rods<br />
■ No mechanical components in<br />
the stirring system<br />
Accessories<br />
Item<br />
Test set for AL606<br />
We also supply a test set to check for correct operation of the<br />
AL606 BOD meter. The set contains 8 BOD CM1 test tablets that<br />
cause a defined oxygen consumption.<br />
The tablets are easy to use. Simply place a tablet in the BOD<br />
bottle, start the measurement process, read off the BOD value<br />
after 5 days, and then compare with the defined value. If this<br />
value is within the quoted tolerance, this means that the BOD<br />
measuring system is functioning correctly.<br />
Temperature equalisation during BOD<br />
measurement<br />
Order code<br />
Sensor head 2444430<br />
BOD sample bottle 418644<br />
Brown glass, 500 ml<br />
BOD sample bottles, Brown glass, 418645<br />
500 ml, set of 6 bottles<br />
Cable for connection to a PC 2444440<br />
serial 9-pins<br />
Inductive stirring system 2444451<br />
for 6 samples, 110-240 V / 50-60 Hz<br />
Stirring rod 418637<br />
Stirring rod remover 418638<br />
Rubber gasket 418636<br />
Chemicals:<br />
Potassium hydroxide solution 2418634<br />
45 %, 50 ml<br />
Nitrification inhibitor (N-ATH) 2418642<br />
50 ml<br />
Overflow flask, 21.7 ml 418664<br />
Overflow flask, 56 ml 418655<br />
Overflow flask, 94 ml 418656<br />
Overflow flask, 157 ml 418657<br />
Overflow flask, 244 ml 418658<br />
Overflow flask, 360 ml 418659<br />
Overflow flask, 428 ml 418660<br />
Complete set 418654<br />
Overflow flasks<br />
Test set, BOD CM test tablets, 418328<br />
box with 8 tablets<br />
Temperature equalisation is essential prior to biological testing,<br />
as temperature has a major effect on biological activity. BOD<br />
measurements, for example, are always performed in a thermostatically<br />
controlled cabinet at a temperature of 20°C.<br />
For temperature equalisation, we recommend AQUALYTIC ®<br />
thermostatically controlled cabinets with a user-selectable<br />
temperature from 2°C to 40°C.<br />
57<br />
General Catalogue January 2010