<strong>HY3118</strong>/<strong>HY3116</strong><br />

24-Bit Analog-to-Digital Convert<br />

High Resolution Σ∆ADC<br />

9.4. Input Channel Multiplexer with IRQ<br />

• Flexible input multiplexer for measurement<br />

and reference signal<br />

• Network switchable input multiplexer<br />

design and ADC conversion data<br />

suppression function<br />

• Steady time calculation for ADC<br />

conversion data suppressed output<br />

• Response IRQ function for end of ADC<br />

data conversion<br />

Measurement signal input network<br />

.<br />

Reference voltage input network<br />

Figure 23 Input Channel Multiplexer<br />

Signal input is featured with flexible network switchable multiplexer design. After<br />

the input network controller is switched, the embedded data conversion suppressor is<br />

initiated to delay data update in ADO[23:0] register until ADC data conversion is<br />

completed. The data update steady time can be derived from the equation described<br />

below:<br />

t<br />

ADC<br />

Stable<br />

1<br />

128<br />

4 <br />

f<br />

ADC<br />

OSCS<br />

1<br />

f<br />

…………………………………………….. (Formula 1)<br />

ADC<br />

OSR<br />

tStable<br />

: steady time after ADC network switch<br />

ADC<br />

fOSCS<br />

: ADC sampling frequency<br />

ADC<br />

fOSR<br />

: ADC conversion frequency<br />

If IRQEN of ADC4[7:0] is set to “1”, then a piece of data will be written into<br />

register ADO[23:0] and an IRQ signal will be generated at SDA pin. The IRQ signal is a<br />

low potential pulse signal that triggers the master end to read contents in ADO[23:0]<br />

after being received at the master end.<br />

Please note that after configuration of the input channel multiplexer is switched,<br />

both the +/- input short or exchange and reference voltage change need a period of<br />

ADC<br />

t before the ADC can generate valid conversion data or interruption response IRQ.<br />

Stable<br />

ADC<br />

© 2011-2014 HYCON Technology Corp<br />

www.hycontek.com<br />

DS-<strong>HY3118</strong>- V08_EN<br />

Page 34