PUMPS &<br />
<strong>FLUID</strong> <strong>ENDS</strong><br />
PUMPS & <strong>FLUID</strong> <strong>ENDS</strong><br />
up to 15,000 PSI (1000 Bar)<br />
UNx ® Fluid End Upgrades<br />
model 4515B<br />
The <strong>Jetstream</strong> UNx Fluid End Upgrade is ideal for<br />
replacing a damaged, costly, or unreliable fluid end.<br />
It is also a cost-effective solution to increase the available<br />
operating pressure or range of pressures for those<br />
who have already converted to the UNx. The upgrade<br />
delivers all of the benefits of the UNx Fluid End design.<br />
• Three plunger (triplex) design<br />
• Superior performance<br />
• Greater flexibility in the field<br />
• Reduced downtime and maintenance<br />
• See UNx Features and Benefits on page B-1<br />
• Clamp-style plungers<br />
• Includes hose adapters and one rupture<br />
disc holder<br />
• Choose an additional rupture disc holder<br />
or a Severe Service Relief Valve as a<br />
second safety device<br />
• Pressure gauge and burst discs not included<br />
• Bolt-on installation requires only minutes<br />
• Once upgraded to the UNx design, the unit can be<br />
supplemented with additional fluid ends to expand<br />
its range of operating pressures.<br />
Fits the following pump models:<br />
Butterworth-Partek — L-450, T-450, TF-450, L-200<br />
Gardner-Denver — TF-450<br />
General Specs<br />
Plungers<br />
Connection Types*<br />
Stroke Discharge Top Ports<br />
#<br />
Supply Port<br />
Ports (Accessory)<br />
in mm<br />
3 4.50 114 3/4" NPT Fml 1/2" NPT Fml 2" NPT Fml<br />
* See details on all connection types beginning on page I-2.<br />
Related Items<br />
SEVERE SERVICE RELIEF VALVES – See page G-2<br />
Burst Discs – See page G-1<br />
Pressure GAUGES – See page F-1<br />
Plunger Packages – See page B-54<br />
Spare Parts Packages – See page B-53<br />
Pump tools – See page B-55<br />
Fluid End Specs<br />
Part<br />
No.<br />
Plunger Size Flow at Specified Pump Speeds** Power Max. Flow / Pressure<br />
Diameter 150 RPM 200 RPM 300 RPM 400 RPM 500 RPM Input Flow** Pressure<br />
No.<br />
in mm gpm lpm gpm lpm gpm lpm gpm lpm gpm lpm hp kW gpm lpm psi bar<br />
51840 #10 .980 24.89 6.6 25 8.8 33 13.2 50 17.6 67 22.1 84<br />
51845 #11 1.100 27.94 8.3 32 11.1 42 16.7 63 22.2 84 27.8 105<br />
51850 #12 1.200 30.48 9.9 38 13.2 50 19.8 75 26.4 100 33.1 125<br />
51855 #13 1.335 33.91 12.3 46 16.4 62 24.6 93 32.7 124 40.9 155<br />
51860 #15 1.500 38.10 15.5 59 20.7 78 31.0 117 41.3 156 51.7 196<br />
J55775 #16 1.670 42.42 19.2 73 25.6 97 38.4 145 51.2 194 64.0 242<br />
215 160 22.1 84 15,000 1000<br />
260 194 26.9 102 15,000 1000<br />
215 160 27.8 105 12,000 825<br />
300 224 31.0 117 15,000 1000<br />
260 194 33.1 125 12,000 825<br />
215 160 33.1 125 10,000 700<br />
300 224 38.8 147 12,000 825<br />
260 194 40.3 153 10,000 700<br />
215 160 40.9 155 8,000 550<br />
300 224 46.5 176 10,000 700<br />
260 194 50.4 191 8,000 550<br />
215 160 51.3 194 6,500 450<br />
300 224 58.1 220 8,000 550<br />
260 194 62.0 235 6,500 450<br />
215 160 64.0 242 5,000 350<br />
** Displacement (flow) values represented refer to “theoretical” flow, neglecting inefficiency resulting from compressibility of water and expansion of pressurebearing<br />
components. Performance data is based on power end specifications published by the original equipment manufacturer; however, some power ends<br />
may differ from those used to determine the values above. Contact a <strong>Jetstream</strong> Solutions Provider for help with fluid end selection.<br />
<strong>Jetstream</strong> of Houston, LLP<br />
Phone: US & Canada: 800-231-8192 or 813-590-1300<br />
Web Site: www.waterblast.com<br />
B-29<br />
Copyright <strong>Jetstream</strong> of Houston, LLP © 2011<br />
Effective 2/2011