Chapter 4<br />

Preventive Maintenance<br />

There is no speed adjustment on this<br />

liftgate.<br />

Lowering speed is controlled by the pressure<br />

compensative valve plumbed at the cylinder.<br />

Regardless of weight on platform, liftgate<br />

should lower at approximately six (6) inches<br />

per second.<br />

Bed Height<br />

(inches)<br />

6<br />

= Lowering Time<br />

(seconds)<br />

Pressure<br />

Compensative Flow<br />

Control Valve<br />

This liftgate must have the correct<br />

pressure compensative valve<br />

install:<br />

GR00160<br />

INSPECT DECALS AND LUBRICATE<br />

LIFTGATE<br />

Inspect all decals per Chapter 5 of this manual.<br />

Replace any that are missing or damaged.<br />

Lubricate liftgate per Chapter 6 of this manual.<br />

ANNUAL INSPECTION<br />

Inspect power motor:<br />

Disconnect battery cable.<br />

Remove end cover.<br />

Examine armature brushes for wear<br />

(Motor should be replaced if less than<br />

1/8" long).<br />

Clean out all residue from inside of<br />

motor housing.<br />

Apply several drops of light weight<br />

machine oil to armature shaft bearing in<br />

motor end cover.<br />

Reassemble motor.<br />

Drain hydraulic fluid and replace with new fluid<br />

per recommended fluids chart.<br />

Remove cover to<br />

check brushes and<br />

clean out motor<br />

GR02836<br />