Chapter 4<br />
Preventive Maintenance<br />
There is no speed adjustment on this<br />
liftgate.<br />
Lowering speed is controlled by the pressure<br />
compensative valve plumbed at the cylinder.<br />
Regardless of weight on platform, liftgate<br />
should lower at approximately six (6) inches<br />
per second.<br />
Bed Height<br />
(inches)<br />
6<br />
= Lowering Time<br />
(seconds)<br />
Pressure<br />
Compensative Flow<br />
Control Valve<br />
This liftgate must have the correct<br />
pressure compensative valve<br />
install:<br />
GR00160<br />
INSPECT DECALS AND LUBRICATE<br />
LIFTGATE<br />
Inspect all decals per Chapter 5 of this manual.<br />
Replace any that are missing or damaged.<br />
Lubricate liftgate per Chapter 6 of this manual.<br />
ANNUAL INSPECTION<br />
Inspect power motor:<br />
Disconnect battery cable.<br />
Remove end cover.<br />
Examine armature brushes for wear<br />
(Motor should be replaced if less than<br />
1/8" long).<br />
Clean out all residue from inside of<br />
motor housing.<br />
Apply several drops of light weight<br />
machine oil to armature shaft bearing in<br />
motor end cover.<br />
Reassemble motor.<br />
Drain hydraulic fluid and replace with new fluid<br />
per recommended fluids chart.<br />
Remove cover to<br />
check brushes and<br />
clean out motor<br />
GR02836<br />
Page 4-5