Assembly instructions - KLARO GmbH
Assembly instructions - KLARO GmbH
Assembly instructions - KLARO GmbH
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>Assembly</strong> <strong>instructions</strong> <strong>KLARO</strong> UV hygienisation stage<br />
3.2. Scope of delivery<br />
The UV hygienisation stage (without control cabinet and retrofit kit) for the internal<br />
assembly consists of the following components.<br />
Item no.: Quantity Description<br />
1 UNIT<br />
1 UNIT<br />
UV reactor with pump* on retaining<br />
plate<br />
UV reactor with siphon on retaining<br />
plate<br />
909006<br />
UV module<br />
S50<br />
with pump<br />
909007<br />
UV module<br />
S50<br />
without pump<br />
909006<br />
UV module<br />
S80<br />
with pump<br />
● ○ ●<br />
○ ● ○<br />
5 m Radiator cable 4x 0.5 mm² ○ ○ ●<br />
20 m Radiator cable 4x 0.5 mm² ● ● ○<br />
5 m<br />
20 m<br />
901356 1 UNIT<br />
Earthing cable H07V-K 1x 2.5 mm²<br />
gn/ye<br />
Earthing cable H07V-K 1x 2.5 mm²<br />
gn/ye<br />
○ ○ ●<br />
● ● ○<br />
1 UNIT Switching unit** 180 x 254 x 111 mm ● ○ ●<br />
1 UNIT Switching unit**180 x 180 x 111 mm ○ ● ○<br />
VA retaining bar with an overall<br />
length of 996mm<br />
● ● ●<br />
980359 3 UNITS Heavy-duty anchor B8-4/60 A4 ● ● ●<br />
980639 2 UNITS Pipe clamp PE DN40 ● ● ●<br />
980156 6 UNITS<br />
Nail dowel M6X40 V2A countersunk<br />
head<br />
● ● ●<br />
980076 4 UNITS Cable tie 280/4.5 mm bl. ● ● ●<br />
When assembling the hygienisation stage in an A cabinet, the following components<br />
must be added.<br />
Item no.: Quantity Description<br />
981462 1 UNIT<br />
Retaining plate for UV<br />
switching device<br />
909006<br />
UV module S50<br />
with pump<br />
909007<br />
UV module<br />
S50<br />
without pump<br />
909008<br />
UV module S80<br />
with pump<br />
● ● ●<br />
980551 8 UNITS Screws M5x12 ● ● ●<br />
980011 8 UNITS Hexagonal nut M5 ● ● ●<br />
980612 4 UNITS Drill screw 4.2 x 19 ● ● ●<br />
980003 4 UNITS Washer D 6.4 ● ● ●<br />
○ Not included in the scope of delivery● Included in the scope of delivery<br />
* The pump is delivered together with a connection cable YSLY-JB 3x 1 mm² with a length of 18 m.<br />
** The switching unit is delivered together with a connection cable YSLY-JB 3x 1 mm² with a length<br />
of 2.5 m.<br />